{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EVS20H3MW20","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EVS20H3MW20","canonicalUrl":"https://aoctrl.com/schneider/EVS20H3MW20","factsUrl":"https://aoctrl.com/api/mcp/products/EVS20H3MW20","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EVS series, EVS20H3MW20, 3-pole drawout circuit breaker, 2000 A rated current, 65 kA breaking capacity at 440 V AC, IEC 60947-2.","salesMarkdown":"## Panel integration note — EVS20H3MW20 The Schneider Electric EVS20H3MW20 is a 3-pole drawout circuit breaker from the EasyPact EVS family, rated 2000 A at 40 °C with a 65 kA Icu breaking capacity at 220...440 V AC 50/60 Hz per IEC 60947-2. The drawout mounting and rear connection position mean the breaker slides onto a rail base plate — no need to disconnect main power cables during swap-out, which cuts downtime on a 2000 A feeder. The 2000 A trip unit rating and 65 kA Icu at 440 V tell you this breaker handles main or heavy feeder duty in a 480 V class distribution panel. Category B utilization means it's designed for selectivity with downstream breakers — the 25 ms maximum breaking time lets upstream devices ride through a fault without tripping. ## Integration checklist Mounts on a rail base plate with a 115 mm connection pitch without spreader. The 395 mm depth, 441 mm width, and 439 mm height require a swing-clear door or adequate front access for drawout racking. IP40 protection means it's for indoor panel installation — no washdown exposure. The electronic EVS Trip System2.0 provides LI protection (overload long-time and instantaneous short-circuit) with a 20-minute thermal memory that accounts for prior heating when re-energizing after a trip.","metaTitle":"Schneider Electric EVS20H3MW20 EasyPact EVS Circuit Breaker,","metaDescription":"Schneider Electric EVS20H3MW20 EasyPact EVS circuit breaker. 2000 A rated current, 65 kA breaking capacity at 440 V. IEC 60947-2, 3-pole drawout. Available to order, quoted on requ","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"395 mm","Range":"EasyPact","Width":"441 mm","Height":"439 mm","Standards":"IEC 60947-2","Control type":"Manually operated","Network type":"AC","Mounting mode":"Drawout","Thermal memory":"20 minutes before and after tripping","Trip unit name":"EVS Trip System2.0","Protection type":"Overload protection (long time) Instantaneous short-circuit protection","lifecycle_stage":"current","Connection pitch":"115 mm without spreader","Mounting support":"Rail Base plate","Pollution degree":"4 conforming to IEC 60664-1","Range of product":"EasyPact EVS","Trip unit rating":"2000 A","Breaking capacity":"65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"EVS20H","Network frequency":"50/60 Hz","Poles description":"3P","Device application":"Distribution","[In] rated current":"2000 A at 40 °C","Connection position":"Vertical Horizontal","Trip unit technology":"Electronic","Utilisation category":"Category B","Electrical durability":"Category B: 5000 cycles 440/690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2","Maximum breaking time":"25 ms","Mechanical durability":"20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2","Breaking capacity code":"H","Location of connection":"Rear","IP degree of protection":"IP40","Circuit breaker CT rating":"2000 A","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","Protected poles description":"3P 3d","Maximum closing response time":"70 ms","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz conforming to IEC 60947-2","Trip unit protection functions":"LI","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Long time delay adjustment type":"Adjustable 9 settings","Zone selective interlocking ZSI":"With","Long time pick-up adjustment range":"0.4...1 x In","Ambient air temperature for storage":"-40...85 °C without control unit -25...85 °C with control unit","Long time pick-up adjustment type Ir":"Adjustable 9 settings","Ambient air temperature for operation":"-5...70 °C","[Ics] rated service breaking capacity":"65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2","[Tr] Long-Time Delay Adjustment Range":"0.5...24 s at 6 x Ir","Instantaneous pick-up adjustment range":"1.5...10 x Ir","[Uimp] rated impulse withstand voltage":"12 kV conforming to IEC 60947-2","Instantaneous pick-up adjustment type Ii":"Adjustable 9 settings","[Icw] rated short-time withstand current":"65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2","[Icm] rated short-circuit making capacity":"143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 105 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f8a07b2b20bcc6ff81f39b661eef1e03.pdf","sourceUrl":"https://www.se.com/vn/en/product/EVS20H3MW20/easypact-evs-2000a-65ka-3p-mdo-trip-system2-0-circuit-breaker/","alternativesUrl":"https://aoctrl.com/api/mcp/products/EVS20H3MW20/alternatives.json"},"ai":{"faq":[{"question":"What is EVS20H3MW20's depth, width, and height?","answer":"The EVS20H3MW20 has a depth of 395 mm, a width of 441 mm, and a height of 439 mm."},{"question":"What standards does EVS20H3MW20 comply with?","answer":"The EVS20H3MW20 complies with IEC 60947-2, with a pollution degree of 4 per IEC 60664-1. It is suitable for isolation per IEC 60947-2."},{"question":"Where can I buy EVS20H3MW20?","answer":"The EVS20H3MW20 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EVS20H3MW20","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EVS20H3MW20 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}