{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EVS25H3MW60","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EVS25H3MW60","canonicalUrl":"https://aoctrl.com/schneider/EVS25H3MW60","factsUrl":"https://aoctrl.com/api/mcp/products/EVS25H3MW60","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EVS, EVS25H3MW60, 3-pole drawout circuit breaker, 2500 A, 65 kA Icu at 440 V AC, IEC 60947-2.","salesMarkdown":"## What the 2500 A and 65 kA ratings mean for your distribution board The EVS25H3MW60 is a 3-pole drawout air circuit breaker from the Schneider Electric EasyPact EVS range, rated 2500 A continuous at 40 °C with a 65 kA Icu breaking capacity at 220...440 V AC. The 2500 A frame is sized for large distribution transformers or heavy industrial feeders; the drawout design lets you rack the breaker out for maintenance without disturbing the bus connections. ## Trip system and protection profile The EVS Trip System6.0 electronic trip unit provides overload (long-time), instantaneous short-circuit, short-time short-circuit, and earth-fault protection. The 20-minute thermal memory means the trip curve accounts for prior heating — if a motor starts twice in quick succession, the breaker remembers the first start and trips sooner on the second, preventing cumulative overheating of downstream cables. Category B utilisation means the breaker is designed for selectivity with downstream devices: it can hold a short-time delay to let a feeder breaker clear first, then trip itself if the fault persists. The 25 ms maximum break time is fast enough to limit let-through energy. ## Mounting and integration into a switchboard Drawout mounting on a rail base plate with rear vertical or horizontal connections. The 115 mm connection pitch without spreader matches standard bus-bar centres for a 2500 A frame. IP40 protection is typical for indoor switchgear — no special washdown rating, so keep it in a clean, dry enclosure. The 441 mm width, 439 mm height, and 395 mm depth fit standard low-voltage switchgear cubicle compartments.","metaTitle":"Schneider Electric EVS25H3MW60 EasyPact EVS Circuit Breaker,","metaDescription":"Schneider Electric EasyPact EVS25H3MW60 drawout circuit breaker, 2500 A rated current, 65 kA Icu at 440 V AC, IEC 60947-2. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"395 mm","Range":"EasyPact","Width":"441 mm","Height":"439 mm","Standards":"IEC 60947-2","Control type":"Manually operated","Network type":"AC","Mounting mode":"Drawout","Thermal memory":"20 minutes before and after tripping","Trip unit name":"EVS Trip System6.0","Protection type":"Overload protection (long time) Instantaneous short-circuit protection Short time short-circuit protection Earth fault","lifecycle_stage":"current","Connection pitch":"115 mm without spreader","Fault indication":"Internal fault Overload Short-circuit Earth fault","Mounting support":"Rail Base plate","Pollution degree":"4 conforming to IEC 60664-1","Range of product":"EasyPact EVS","Trip unit rating":"2500 A","Breaking capacity":"65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"EVS25H","Network frequency":"50/60 Hz","Poles description":"3P","Device application":"Distribution","[In] rated current":"2500 A at 40 °C","Connection position":"Vertical Horizontal","Trip unit technology":"Electronic","Utilisation category":"Category B","Electrical durability":"Category B: 5000 cycles 440/690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2","Maximum breaking time":"25 ms","Mechanical durability":"20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2","Breaking capacity code":"H","Location of connection":"Rear","IP degree of protection":"IP40","Circuit breaker CT rating":"2500 A","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","Protected poles description":"3P 3d","Maximum closing response time":"70 ms","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz conforming to IEC 60947-2","Trip unit protection functions":"LSIG","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Long time delay adjustment type":"Adjustable 9 settings","Zone selective interlocking ZSI":"With","Short-time delay adjustment type":"Adjustable 5 settings","Long time pick-up adjustment range":"0.4...1 x In","Ambient air temperature for storage":"-40...85 °C without control unit -25...85 °C with control unit","Ground-fault pick-up adjustment type":"Adjustable 9 settings","Long time pick-up adjustment type Ir":"Adjustable 9 settings","Ambient air temperature for operation":"-5...70 °C","[Ics] rated service breaking capacity":"65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2","[Tr] Long-Time Delay Adjustment Range":"0.5...24 s at 6 x Ir","Instantaneous pick-up adjustment range":"2...15 x In Off","Short-time pick-up adjustment type Isd":"Adjustable 9 settings","[Uimp] rated impulse withstand voltage":"12 kV conforming to IEC 60947-2","[Tsd] Short-Time Delay Adjustment Range":"100...400 ms","Instantaneous pick-up adjustment type Ii":"Adjustable 9 settings","[Icw] rated short-time withstand current":"65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2","[Icm] rated short-circuit making capacity":"143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 105 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2","[Isd] short-time pick-up adjustment range":"1.5...10 x Ir","[Ig] ground-fault pick-up adjustment range":"0.2...1 x In","Ground-fault time delay adjustment type -tg":"Adjustable 5 settings","[Tg] Ground-Fault Time Delay Adjustment Range":"100...400 ms"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6217f9f47785031f04ab8c189a63cad9.pdf","sourceUrl":"https://www.se.com/vn/en/product/EVS25H3MW60/easypact-evs-2500a-65ka-3p-mdo-trip-system6-0-circuit-breaker/","alternativesUrl":"https://aoctrl.com/api/mcp/products/EVS25H3MW60/alternatives.json"},"ai":{"faq":[{"question":"Who supplies EVS25H3MW60 and how is it quoted for volume purchases?","answer":"The EVS25H3MW60 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is EVS25H3MW60's listed depth (395 mm) on this component line?","answer":"The EVS25H3MW60 has a depth of 395 mm, a width of 441 mm, and a height of 439 mm."},{"question":"What is EVS25H3MW60's listed range (EasyPact) on this component line?","answer":"The EVS25H3MW60 belongs to the Schneider Electric EasyPact EVS range."},{"question":"What compliance documentation does this brand provide for EVS25H3MW60 (RoHS, REACH, UL, IEC)?","answer":"The EVS25H3MW60 is certified to IEC 60947-2 and carries a suitability for isolation marking per that standard. Compliance documentation is available with the order."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EVS25H3MW60","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EVS25H3MW60 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}