{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EVS25H3NW5A","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EVS25H3NW5A","canonicalUrl":"https://aoctrl.com/schneider/EVS25H3NW5A","factsUrl":"https://aoctrl.com/api/mcp/products/EVS25H3NW5A","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EVS, EVS25H3NW5A, 3-pole drawout circuit breaker, 2500 A rated current, 65 kA Icu at 440 V AC, electronic trip unit EVS Trip System5A.","salesMarkdown":"The EVS25H3NW5A is a 3-pole drawout air circuit breaker from the EasyPact EVS range, rated 2500 A at 40 °C and carrying a 65 kA Icu breaking capacity at 440 V AC (50/60 Hz) per IEC 60947-2. The electronic trip unit (EVS Trip System5A) provides overload (long-time), short-time, and instantaneous short-circuit protection, with a thermal memory that holds the thermal model for 20 minutes before and after a trip — so a reclose-and-trip sequence on a hot conductor is accurately timed. Drawout mounting means the breaker chassis stays wired in the switchgear; the moving portion pulls out for inspection or swap without disturbing the bus connections. The IP40 enclosure keeps out tools and fingers but not fine dust — expect this in a clean indoor switchgear lineup, not a washdown area. ## Integration notes Dimensions: 441 mm wide × 439 mm high × 395 mm deep. Rear connection with a 115 mm pitch without spreader. Mounts on a rail base plate. The drawout cradle needs clearance for the racking mechanism — verify the switchgear cubicle depth against the 395 mm plus handle throw. Pollution degree 4 means it's rated for conductive pollution environments (heavy condensation, occasional conductive dust), typical of industrial switchrooms.","metaTitle":"Schneider Electric EVS25H3NW5A EasyPact EVS 2500 A Circuit B","metaDescription":"Schneider Electric EVS25H3NW5A EasyPact EVS circuit breaker, 2500 A rated current, 65 kA breaking capacity at 440 V AC, IEC 60947-2. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"395 mm","Range":"EasyPact","Width":"441 mm","Height":"439 mm","Standards":"IEC 60947-2","Control type":"Electrically operated","Display type":"Digital display","Network type":"AC","Mounting mode":"Drawout","Thermal memory":"20 minutes before and after tripping","Trip unit name":"EVS Trip System5A","Protection type":"Overload protection (long time) Instantaneous short-circuit protection Short time short-circuit protection","lifecycle_stage":"current","Connection pitch":"115 mm without spreader","Fault indication":"Internal fault Overload Short-circuit","Mounting support":"Rail Base plate","Pollution degree":"4 conforming to IEC 60664-1","Range of product":"EasyPact EVS","Trip unit rating":"2500 A","Breaking capacity":"65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"EVS25H","Network frequency":"50/60 Hz","Poles description":"3P","Device application":"Distribution","[In] rated current":"2500 A at 40 °C","Connection position":"Vertical Horizontal","Type of measurement":"Current","Trip unit technology":"Electronic","Utilisation category":"Category B","Electrical durability":"Category B: 5000 cycles 440/690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2","Maximum breaking time":"25 ms","Mechanical durability":"20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2","Breaking capacity code":"H","Location of connection":"Rear","IP degree of protection":"IP40","Circuit breaker CT rating":"2500 A","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","Protected poles description":"3P 3d","Maximum closing response time":"70 ms","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz conforming to IEC 60947-2","Trip unit protection functions":"LSI","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Long time delay adjustment type":"Adjustable 9 settings","Zone selective interlocking ZSI":"With","Short-time delay adjustment type":"Adjustable 5 settings","Long time pick-up adjustment range":"0.4...1 x In","Ambient air temperature for storage":"-40...85 °C without control unit -25...85 °C with control unit","Long time pick-up adjustment type Ir":"Adjustable 9 settings","Ambient air temperature for operation":"-5...70 °C","[Ics] rated service breaking capacity":"65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2","[Tr] Long-Time Delay Adjustment Range":"0.5...24 s at 6 x Ir","Instantaneous pick-up adjustment range":"2...15 x In Off","Short-time pick-up adjustment type Isd":"Adjustable 9 settings","[Uimp] rated impulse withstand voltage":"12 kV conforming to IEC 60947-2","[Tsd] Short-Time Delay Adjustment Range":"100...400 ms","Instantaneous pick-up adjustment type Ii":"Adjustable 9 settings","[Icw] rated short-time withstand current":"65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2","[Icm] rated short-circuit making capacity":"143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 105 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2","[Isd] short-time pick-up adjustment range":"1.5...10 x Ir"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/20dfc97e1597b7a7caa35d6c25753735.pdf","sourceUrl":"https://www.se.com/vn/en/product/EVS25H3NW5A/easypact-evs-2500a-65ka-3p-edo-240vac-trip-system5-0a-circuit-breaker/","alternativesUrl":"https://aoctrl.com/api/mcp/products/EVS25H3NW5A/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative to EVS25H3NW5A in the EasyPact EVS family?","answer":"Within the same EasyPact EVS range, the closest sibling is the EVS25H3NW5A itself — there is no pin-for-pin alternative with identical ratings. If you need a different breaking capacity code (e.g., S, N, or L) or a different trip unit, the frame size and drawout footprint remain the same, but the trip unit and breaking capacity change. Check the spec line for your required Icu at the system voltage."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EVS25H3NW5A","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EVS25H3NW5A when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}