{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EVS32H3MW5A","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EVS32H3MW5A","canonicalUrl":"https://aoctrl.com/schneider/EVS32H3MW5A","factsUrl":"https://aoctrl.com/api/mcp/products/EVS32H3MW5A","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EVS, EVS32H3MW5A, drawout circuit breaker, 3-pole, 3200 A rated current, 65 kA breaking capacity at 440 V AC, electronic trip unit.","salesMarkdown":"The EVS32H3MW5A is a 3200 A drawout air circuit breaker from the Schneider EasyPact EVS family, built for distribution-duty in industrial switchboards. It's a three-pole unit with an electronic EVS Trip System5A trip unit that handles overload, short-time, and instantaneous protection. The 65 kA Icu at 440 V AC (50/60 Hz) per IEC 60947-2 means it can interrupt fault currents up to that level without upstream damage — that's the rating that decides whether this breaker holds in a high-fault panel or blows through. At 690 V the breaking capacity drops to 50 kA, still solid for most 690 V distribution. The drawout mounting lets you rack the breaker out for maintenance without pulling bus connections — a real time-saver when you're swapping a trip unit mid-shift. Drawout mounting on a rail base plate — the breaker chassis slides onto a fixed cradle with rear connection points. The 395 mm depth and 441 mm width give you a solid footprint for a 3200 A frame; make sure your switchgear cubicle has the clearance for the racking mechanism. Vertical or horizontal connection orientation is supported, which helps when you're laying out bus bars in a tight enclosure. The IP40 front-face protection is standard for indoor switchgear — no special sealing needed for a clean panel environment. Category B utilization means it's designed for selectivity with downstream breakers — the 5000-cycle electrical durability at 440/690 V without maintenance is the endurance figure for that duty. The 25 ms maximum break time is fast enough to limit let-through energy on a hard fault. Built to IEC 60947-2 for low-voltage switchgear and controlgear. The digital display on the trip unit gives you real-time current readout and fault indication (overload, short-circuit, internal fault), which saves time during commissioning and troubleshooting.","metaTitle":"Schneider Electric EVS32H3MW5A EasyPact EVS Circuit Breaker,","metaDescription":"Schneider Electric EVS32H3MW5A EasyPact EVS drawout circuit breaker, 3200 A rated current, 65 kA breaking capacity at 440 V AC. IEC 60947-2, current lifecycle stage. Available to o","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"395 mm","Range":"EasyPact","Width":"441 mm","Height":"439 mm","Standards":"IEC 60947-2","Control type":"Manually operated","Display type":"Digital display","Network type":"AC","Mounting mode":"Drawout","Thermal memory":"20 minutes before and after tripping","Trip unit name":"EVS Trip System5A","Protection type":"Overload protection (long time) Instantaneous short-circuit protection Short time short-circuit protection","lifecycle_stage":"current","Connection pitch":"115 mm without spreader","Fault indication":"Internal fault Overload Short-circuit","Mounting support":"Rail Base plate","Pollution degree":"4 conforming to IEC 60664-1","Range of product":"EasyPact EVS","Trip unit rating":"3200 A","Breaking capacity":"65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"EVS32H","Network frequency":"50/60 Hz","Poles description":"3P","Device application":"Distribution","[In] rated current":"3200 A at 40 °C","Connection position":"Vertical Horizontal","Type of measurement":"Current","Trip unit technology":"Electronic","Utilisation category":"Category B","Electrical durability":"Category B: 5000 cycles 440/690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2","Maximum breaking time":"25 ms","Mechanical durability":"20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2","Breaking capacity code":"H","Location of connection":"Rear","IP degree of protection":"IP40","Circuit breaker CT rating":"3200 A","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","Protected poles description":"3P 3d","Maximum closing response time":"70 ms","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz conforming to IEC 60947-2","Trip unit protection functions":"LSI","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Long time delay adjustment type":"Adjustable 9 settings","Zone selective interlocking ZSI":"With","Short-time delay adjustment type":"Adjustable 5 settings","Long time pick-up adjustment range":"0.4...1 x In","Ambient air temperature for storage":"-40...85 °C without control unit -25...85 °C with control unit","Long time pick-up adjustment type Ir":"Adjustable 9 settings","Ambient air temperature for operation":"-5...70 °C","[Ics] rated service breaking capacity":"65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2","[Tr] Long-Time Delay Adjustment Range":"0.5...24 s at 6 x Ir","Instantaneous pick-up adjustment range":"2...15 x In Off","Short-time pick-up adjustment type Isd":"Adjustable 9 settings","[Uimp] rated impulse withstand voltage":"12 kV conforming to IEC 60947-2","[Tsd] Short-Time Delay Adjustment Range":"100...400 ms","Instantaneous pick-up adjustment type Ii":"Adjustable 9 settings","[Icw] rated short-time withstand current":"65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2","[Icm] rated short-circuit making capacity":"143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 105 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2","[Isd] short-time pick-up adjustment range":"1.5...10 x Ir"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b6838207fc3b4fa65eaea85dfc5c2a82.pdf","sourceUrl":"https://www.se.com/vn/en/product/EVS32H3MW5A/easypact-evs-3200a-65ka-3p-mdo-trip-system5-0a-circuit-breaker/","alternativesUrl":"https://aoctrl.com/api/mcp/products/EVS32H3MW5A/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy EVS32H3MW5A and how do I get a price?","answer":"This breaker is sourced to order through independent distribution. Submit an RFQ against this order code; availability and current pricing are confirmed at quote time."},{"question":"What is EVS32H3MW5A's breaking capacity at 440 V?","answer":"65 kA Icu at 220...440 V AC 50/60 Hz per IEC 60947-2. At 690 V the rating drops to 50 kA Icu."},{"question":"What compliance documentation does this brand provide for EVS32H3MW5A?","answer":"The breaker is certified to IEC 60947-2 and rated for isolation per that standard. Pollution degree 4 per IEC 60664-1 is confirmed. Standard Schneider documentation includes the datasheet, installation manual, and IEC declaration of conformity."},{"question":"What is the 20-minute thermal memory on the trip unit?","answer":"The EVS Trip System5A retains the thermal state of the breaker for 20 minutes before and after a trip event. This prevents a hot breaker from being re-closed immediately after clearing a fault, reducing the risk of nuisance tripping on a second close."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EVS32H3MW5A","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EVS32H3MW5A when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}