{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EVS32H4MW5A","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EVS32H4MW5A","canonicalUrl":"https://aoctrl.com/schneider/EVS32H4MW5A","factsUrl":"https://aoctrl.com/api/mcp/products/EVS32H4MW5A","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EVS series, EVS32H4MW5A, manually operated circuit breaker, 4 poles, 3200 A rated current, 65 kA Icu at 440 V AC, drawout mounting, IP40.","salesMarkdown":"## What this 3200 A drawout breaker brings to a distribution board The Schneider Electric EVS32H4MW5A is a 4-pole EasyPact EVS circuit breaker rated for 3200 A continuous at 40 °C, with a 65 kA Icu breaking capacity at 440 V AC (50/60 Hz) per IEC 60947-2. The drawout mounting (rails and base plate included) lets you rack the breaker out for maintenance or replacement without disturbing the bus connections, which is the standard practice for switchgear where downtime on a 3200 A feeder is measured in minutes, not hours. The EVS Trip System5A electronic trip unit handles overload (long-time), short-time, and instantaneous short-circuit protection, with a 20-minute thermal memory that remembers the heat profile before and after a trip — so if you reclose on a hot breaker, it won't let a second overload cook the cable. The digital display shows fault type (overload, short-circuit, internal fault) and measured current, which saves the panel guy from guessing what tripped it. At 3200 A and 65 kA Icu, this breaker sits in the heavy end of the EasyPact EVS range — it's sized for main incomers or large bus risers, not branch feeders. The Category B utilization (IEC 60947-2) means it's designed for selectivity with downstream breakers: the short-time delay lets a fault ride through long enough for the nearest downstream device to clear, keeping the rest of the board live. Electrical durability is 5000 cycles at rated voltage without maintenance; mechanical durability is 20000 cycles with maintenance, 10000 without. That's enough for a main breaker that cycles once or twice a day, not a switching-duty device. The IP40 enclosure keeps tools and fingers out but isn't washdown-rated; it's for clean indoor switchgear. ## Integration notes — drawout frame, connections, and isolation Mounts on a rail or base plate with rear vertical or horizontal connections spaced at 115 mm pitch without a spreader. The drawout design means you need racking clearance above and below — 395 mm depth and 441 mm width give the panel builder the envelope to plan gland plates and bus bar takeoffs.","metaTitle":"Schneider Electric EVS32H4MW5A EasyPact EVS Circuit Breaker,","metaDescription":"Schneider Electric EVS32H4MW5A EasyPact EVS circuit breaker, 3200 A rated current, 65 kA Icu at 440 V AC, 4 poles, drawout mount, IEC 60947-2. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"395 mm","Range":"EasyPact","Width":"441 mm","Height":"439 mm","Standards":"IEC 60947-2","Control type":"Manually operated","Display type":"Digital display","Network type":"AC","Mounting mode":"Drawout","Thermal memory":"20 minutes before and after tripping","Trip unit name":"EVS Trip System5A","Protection type":"Overload protection (long time) Instantaneous short-circuit protection Short time short-circuit protection","lifecycle_stage":"current","Connection pitch":"115 mm without spreader","Fault indication":"Internal fault Overload Short-circuit","Mounting support":"Rail Base plate","Pollution degree":"4 conforming to IEC 60664-1","Range of product":"EasyPact EVS","Trip unit rating":"3200 A","Breaking capacity":"65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"EVS32H","Network frequency":"50/60 Hz","Poles description":"4P","Device application":"Distribution","[In] rated current":"3200 A at 40 °C","Connection position":"Vertical Horizontal","Type of measurement":"Current","Trip unit technology":"Electronic","Utilisation category":"Category B","Electrical durability":"Category B: 5000 cycles 440/690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2","Maximum breaking time":"25 ms","Mechanical durability":"20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2","Breaking capacity code":"H","Location of connection":"Rear","IP degree of protection":"IP40","Circuit breaker CT rating":"3200 A","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","Protected poles description":"4P 4d","Maximum closing response time":"70 ms","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz conforming to IEC 60947-2","Trip unit protection functions":"LSI","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Long time delay adjustment type":"Adjustable 9 settings","Zone selective interlocking ZSI":"With","Short-time delay adjustment type":"Adjustable 5 settings","Long time pick-up adjustment range":"0.4...1 x In","Ambient air temperature for storage":"-40...85 °C without control unit -25...85 °C with control unit","Long time pick-up adjustment type Ir":"Adjustable 9 settings","Ambient air temperature for operation":"-5...70 °C","[Ics] rated service breaking capacity":"65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2","[Tr] Long-Time Delay Adjustment Range":"0.5...24 s at 6 x Ir","Instantaneous pick-up adjustment range":"2...15 x In Off","Short-time pick-up adjustment type Isd":"Adjustable 9 settings","[Uimp] rated impulse withstand voltage":"12 kV conforming to IEC 60947-2","[Tsd] Short-Time Delay Adjustment Range":"100...400 ms","Instantaneous pick-up adjustment type Ii":"Adjustable 9 settings","[Icw] rated short-time withstand current":"65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2","[Icm] rated short-circuit making capacity":"143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 105 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2","[Isd] short-time pick-up adjustment range":"1.5...10 x Ir"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b7335d65a6d45f64f5e71d3f02a8389d.pdf","sourceUrl":"https://www.se.com/vn/en/product/EVS32H4MW5A/easypact-evs-3200a-65ka-4p-mdo-trip-system5-0a-circuit-breaker/","alternativesUrl":"https://aoctrl.com/api/mcp/products/EVS32H4MW5A/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy the EVS32H4MW5A?","answer":"The EVS32H4MW5A is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What are the key ratings of the EVS32H4MW5A?","answer":"Rated 3200 A at 40 °C, 65 kA Icu at 440 V AC, 4 poles, drawout mount, with an electronic EVS Trip System5A trip unit providing overload, short-time, and instantaneous protection."},{"question":"What compliance documentation does Schneider provide for this breaker?","answer":"The EVS32H4MW5A is designed and tested to IEC 60947-2, with pollution degree 4 per IEC 60664-1. It is suitable for isolation per IEC 60947-2 and carries a Category B utilization rating."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EVS32H4MW5A","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EVS32H4MW5A when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}