{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EVS40H3MW5A","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EVS40H3MW5A","canonicalUrl":"https://aoctrl.com/schneider/EVS40H3MW5A","factsUrl":"https://aoctrl.com/api/mcp/products/EVS40H3MW5A","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EVS40H, EVS40H3MW5A, 4000 A drawout circuit breaker, 65 kA Icu at 440 V AC, 3P, electronic trip unit.","salesMarkdown":"The Schneider Electric EVS40H3MW5A is a 4000 A drawout circuit breaker from the EasyPact EVS40H series, built for main distribution duty. It carries a 65 kA Icu breaking capacity at 220...440 V AC and 50 kA Icu at 690 V AC, both per IEC 60947-2 — so it handles high-fault utility feeds without cascading upstream. The 3-pole design with an electronic EVS Trip System5A unit gives you overload, instantaneous short-circuit, and short-time short-circuit protection, plus a 20-minute thermal memory that remembers the heat profile before and after a trip. That matters for coordination: it keeps downstream devices from nuisance-tripping on a temporary overload. The drawout mounting lets you rack the breaker out for safe maintenance without killing power to the bus; the rear connection bolts directly to the bus bars. IP40 keeps tools and fingers out but expects a clean indoor switchroom. Built to IEC 60947-2 for circuit breakers, with suitability for isolation — so it doubles as a visible-break disconnect when racked out. The utilisation category B means it's designed for selectivity with downstream breakers, not just as a standalone device. Electrical durability is 5000 cycles at rated voltage without maintenance; mechanical durability is 20000 cycles with maintenance, 10000 without. That 25 ms maximum breaking time keeps fault energy low enough to protect downstream gear.","metaTitle":"Schneider Electric EVS40H3MW5A EasyPact EVS40H Circuit Break","metaDescription":"Schneider Electric EVS40H3MW5A EasyPact EVS40H drawout circuit breaker. 4000 A rated current, 65 kA Icu at 440 V AC. IEC 60947-2, 3P, electronic trip unit. Active production, sourc","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"395 mm","Range":"EasyPact","Width":"441 mm","Height":"439 mm","Standards":"IEC 60947-2","Control type":"Manually operated","Display type":"Digital display","Network type":"AC","Mounting mode":"Drawout","Thermal memory":"20 minutes before and after tripping","Trip unit name":"EVS Trip System5A","Protection type":"Overload protection (long time) Instantaneous short-circuit protection Short time short-circuit protection","lifecycle_stage":"current","Connection pitch":"115 mm without spreader","Fault indication":"Internal fault Overload Short-circuit","Mounting support":"Rail Base plate","Pollution degree":"4 conforming to IEC 60664-1","Range of product":"EasyPact EVS","Trip unit rating":"4000 A","Breaking capacity":"65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"EVS40H","Network frequency":"50/60 Hz","Poles description":"3P","Device application":"Distribution","[In] rated current":"4000 A at 40 °C","Connection position":"Vertical Horizontal","Type of measurement":"Current","Trip unit technology":"Electronic","Utilisation category":"Category B","Electrical durability":"Category B: 5000 cycles 440/690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2","Maximum breaking time":"25 ms","Mechanical durability":"20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2","Breaking capacity code":"H","Location of connection":"Rear","IP degree of protection":"IP40","Circuit breaker CT rating":"4000 A","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","Protected poles description":"3P 3d","Maximum closing response time":"70 ms","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz conforming to IEC 60947-2","Trip unit protection functions":"LSI","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Long time delay adjustment type":"Adjustable 9 settings","Zone selective interlocking ZSI":"With","Short-time delay adjustment type":"Adjustable 5 settings","Long time pick-up adjustment range":"0.4...1 x In","Ambient air temperature for storage":"-40...85 °C without control unit -25...85 °C with control unit","Long time pick-up adjustment type Ir":"Adjustable 9 settings","Ambient air temperature for operation":"-5...70 °C","[Ics] rated service breaking capacity":"65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2","[Tr] Long-Time Delay Adjustment Range":"0.5...24 s at 6 x Ir","Instantaneous pick-up adjustment range":"2...15 x In Off","Short-time pick-up adjustment type Isd":"Adjustable 9 settings","[Uimp] rated impulse withstand voltage":"12 kV conforming to IEC 60947-2","[Tsd] Short-Time Delay Adjustment Range":"100...400 ms","Instantaneous pick-up adjustment type Ii":"Adjustable 9 settings","[Icw] rated short-time withstand current":"65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2","[Icm] rated short-circuit making capacity":"143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 105 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2","[Isd] short-time pick-up adjustment range":"1.5...10 x Ir"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/52b5a2d6912c811a06bb82f92c9d2efc.pdf","sourceUrl":"https://www.se.com/vn/en/product/EVS40H3MW5A/easypact-evs-4000a-65ka-3p-mdo-trip-system5-0a-circuit-breaker/","alternativesUrl":"https://aoctrl.com/api/mcp/products/EVS40H3MW5A/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for EVS40H3MW5A?","answer":"Submit an RFQ through this listing. We source this part through independent distribution and confirm availability and current pricing at quote time."},{"question":"What is the breaking capacity of EVS40H3MW5A?","answer":"65 kA Icu at 220...440 V AC and 50 kA Icu at 690 V AC, both per IEC 60947-2."},{"question":"What trip unit does EVS40H3MW5A use?","answer":"It uses the electronic EVS Trip System5A, providing overload (long-time), instantaneous short-circuit, and short-time short-circuit protection."},{"question":"What compliance documentation does Schneider provide for EVS40H3MW5A?","answer":"The breaker is certified to IEC 60947-2 and suitable for isolation per that standard. The manufacturer provides a declaration of performance and conformity with the product."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EVS40H3MW5A","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EVS40H3MW5A when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}