{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EVS40H3MW6A","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EVS40H3MW6A","canonicalUrl":"https://aoctrl.com/schneider/EVS40H3MW6A","factsUrl":"https://aoctrl.com/api/mcp/products/EVS40H3MW6A","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EVS, EVS40H3MW6A, drawout circuit breaker, 3-pole, 4000 A rated current, 65 kA Icu at 440 V AC, electronic trip unit EVS Trip System6A.","salesMarkdown":"The Schneider Electric EVS40H3MW6A is a 3-pole drawout air circuit breaker from the EasyPact EVS range, rated 4000 A continuous at 40 °C and built to IEC 60947-2 for distribution duty. The 4000 A trip unit rating and 65 kA Icu at 440 V AC mean it handles main-feed or heavy-bus faults without cascading upstream — the H breaking-capacity code tells you it's sized for high-fault installations where a standard breaker would weld shut. The electronic EVS Trip System6A provides overload (long-time), instantaneous short-circuit, short-time short-circuit, and earth-fault protection, with a 20-minute thermal-memory reset after a trip so you don't nuisance-trip on a reclose. Drawout mounting means the breaker slides onto a rail or base plate — you can rack it out for maintenance or replacement without disturbing the bus connections. The rear-connected vertical or horizontal terminals accept bus bars or cable lugs at a 115 mm pitch without a spreader. Category B utilisation means it's designed for selectivity with downstream breakers — the short-time delay lets a fault clear closer to the load before this breaker opens. Mechanical durability of 20,000 cycles with maintenance and 10,000 without tells you it's built for a fixed installation, not frequent switching.","metaTitle":"Schneider Electric EVS40H3MW6A EasyPact EVS Circuit Breaker,","metaDescription":"Schneider Electric EVS40H3MW6A EasyPact EVS drawout circuit breaker, 4000 A rated current, 65 kA breaking capacity at 440 V. IEC 60947-2. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"395 mm","Range":"EasyPact","Width":"441 mm","Height":"439 mm","Standards":"IEC 60947-2","Control type":"Manually operated","Display type":"Digital display","Network type":"AC","Mounting mode":"Drawout","Thermal memory":"20 minutes before and after tripping","Trip unit name":"EVS Trip System6A","Protection type":"Overload protection (long time) Instantaneous short-circuit protection Short time short-circuit protection Earth fault","lifecycle_stage":"current","Connection pitch":"115 mm without spreader","Fault indication":"Internal fault Overload Short-circuit Earth fault","Mounting support":"Rail Base plate","Pollution degree":"4 conforming to IEC 60664-1","Range of product":"EasyPact EVS","Trip unit rating":"4000 A","Breaking capacity":"65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"EVS40H","Network frequency":"50/60 Hz","Poles description":"3P","Device application":"Distribution","[In] rated current":"4000 A at 40 °C","Connection position":"Vertical Horizontal","Type of measurement":"Current","Trip unit technology":"Electronic","Utilisation category":"Category B","Electrical durability":"Category B: 5000 cycles 440/690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2","Maximum breaking time":"25 ms","Mechanical durability":"20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2","Breaking capacity code":"H","Location of connection":"Rear","IP degree of protection":"IP40","Circuit breaker CT rating":"4000 A","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","Protected poles description":"3P 3d","Maximum closing response time":"70 ms","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz conforming to IEC 60947-2","Trip unit protection functions":"LSIG","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Long time delay adjustment type":"Adjustable 9 settings","Zone selective interlocking ZSI":"With","Short-time delay adjustment type":"Adjustable 5 settings","Long time pick-up adjustment range":"0.4...1 x In","Ambient air temperature for storage":"-40...85 °C without control unit -25...85 °C with control unit","Ground-fault pick-up adjustment type":"Adjustable 9 settings","Long time pick-up adjustment type Ir":"Adjustable 9 settings","Ambient air temperature for operation":"-5...70 °C","[Ics] rated service breaking capacity":"65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2","[Tr] Long-Time Delay Adjustment Range":"0.5...24 s at 6 x Ir","Instantaneous pick-up adjustment range":"2...15 x In Off","Short-time pick-up adjustment type Isd":"Adjustable 9 settings","[Uimp] rated impulse withstand voltage":"12 kV conforming to IEC 60947-2","[Tsd] Short-Time Delay Adjustment Range":"100...400 ms","Instantaneous pick-up adjustment type Ii":"Adjustable 9 settings","[Icw] rated short-time withstand current":"65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2","[Icm] rated short-circuit making capacity":"143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 105 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2","[Isd] short-time pick-up adjustment range":"1.5...10 x Ir","[Ig] ground-fault pick-up adjustment range":"0.2...1 x In","Ground-fault time delay adjustment type -tg":"Adjustable 5 settings","[Tg] Ground-Fault Time Delay Adjustment Range":"100...400 ms"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f5e8c84f8fd4c67bab95b66022409e2f.pdf","sourceUrl":"https://www.se.com/vn/en/product/EVS40H3MW6A/easypact-evs-4000a-65ka-3p-mdo-trip-system6-0a-circuit-breaker/","alternativesUrl":"https://aoctrl.com/api/mcp/products/EVS40H3MW6A/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of EVS40H3MW6A?","answer":"The EVS40H3MW6A has a breaking capacity of 65 kA Icu at 220...440 V AC and 50 kA Icu at 690 V AC, both per IEC 60947-2. The H breaking-capacity code indicates high-fault-level capability."},{"question":"What protection functions does the EVS Trip System6A provide?","answer":"The EVS Trip System6A electronic trip unit provides overload (long-time), instantaneous short-circuit, short-time short-circuit, and earth-fault protection. It includes a 20-minute thermal memory before and after tripping."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EVS40H3MW6A","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EVS40H3MW6A when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}