{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZC100B3060","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZC100B3060","canonicalUrl":"https://aoctrl.com/schneider/EZC100B3060","factsUrl":"https://aoctrl.com/api/mcp/products/EZC100B3060","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZC100B, circuit breaker, EZC100B3060, 60 A, 3P, TM-D trip unit, 10 kA Icu at 240 V AC, IP20, backplate mount.","salesMarkdown":"The Schneider Electric EZC100B3060 is a 3-pole thermal-magnetic circuit breaker from the EasyPact EZC100B line, rated 60 A at 40 °C ambient. The TM-D trip unit handles overload and short-circuit protection — no earth-leakage module inside. It is a Category A breaker, meaning it is not specifically designed for high-frequency switching but for standard distribution protection. Breaking capacity varies by voltage: 10 kA Icu at 110–130 V AC, 10 kA at 220–240 V, 7.5 kA at 380–415 V, 5 kA at 440 V, and 2.5 kA at 550 V AC. The 5 kA at 440 V means this breaker is not a fit for heavy 480 V industrial mains where SCCR requirements exceed 10 kA; you would step up to the EZC250 or EZC400 frame for that. Rated insulation voltage (Ui) is 690 V AC, and rated operational voltage (Ue) is 550 V AC. Mounts on a backplate with a fixed mounting mode. The connection pitch is 25 mm, and both upside and downside connections are front-facing. Dimensions: 75 mm wide, 130 mm high, 60 mm deep. Mechanical durability is rated at 13,000 cycles. That is standard for a molded-case breaker in this class — not a high-cycle switching device, but fine for a distribution panel where it operates a few times a year.","metaTitle":"Schneider Electric EZC100B3060 EasyPact EZC100B Circuit Brea","metaDescription":"Schneider Electric EZC100B3060 EasyPact EZC100B circuit breaker, 60 A rated current, 3 poles, TM-D thermal-magnetic trip unit, 10 kA breaking capacity at 240 V AC. Active productio","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"60 mm","Width":"75 mm","title":"EZC100B3060","Height":"130 mm","Standards":"EN/IEC 60947-1 GB/T 14048.2 JIS C8201-2-2 EN/IEC 60947-2","description":"circuit breaker, EasyPact EZC100B, TMD, 60A, 3 poles 3d","Control type":"Toggle","Network type":"AC DC","Mounting mode":"Fixed","Trip unit name":"TM-D","Protection type":"Overload protection Short-circuit protection","lifecycle_stage":"current","Connection pitch":"25 mm","Local signalling":"Positive contact indication","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60664-1 3 conforming to IEC 947-1","Range of product":"EasyPact","Trip unit rating":"60 A at 50 °C","Breaking capacity":"10 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"Easypact EZC100B","Network frequency":"50/60 Hz","Poles description":"3P","Upside connection":"Front","Device application":"Distribution","[In] rated current":"60 A at 40 °C","Downside connection":"Front","Circuit breaker name":"Easypact EZC100B","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Mechanical durability":"13000 cycles","Breaking capacity code":"B","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Neutral protection setting":"Without protection","Protected poles description":"3t","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"550 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-35...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"0.625 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 1.25 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 1.875 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 1.875 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$41.14","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/bcfaf8fc0b3f308d5dd70afbf8a4d5f0.pdf","sourceUrl":"https://www.se.com/vn/en/product/EZC100B3060/circuit-breaker-easypact-ezc100b-tmd-60a-3-poles-3d/"},"ai":{"faq":[{"question":"What is the breaking capacity of the EZC100B3060 at 240 V?","answer":"The EZC100B3060 has a breaking capacity of 10 kA Icu at 220–240 V AC 50/60 Hz conforming to IEC 60947-2."},{"question":"Where can I buy the EZC100B3060 and how is it quoted?","answer":"The EZC100B3060 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZC100B3060","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZC100B3060 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}