{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZC100F3016","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZC100F3016","canonicalUrl":"https://aoctrl.com/schneider/EZC100F3016","factsUrl":"https://aoctrl.com/api/mcp/products/EZC100F3016","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZC100F, 3-pole thermal-magnetic circuit breaker, 16 A rated current, 25 kA Icu at 240 V AC, TM-D trip unit.","salesMarkdown":"The EZC100F3016 is a fixed-mount, 3-pole thermal-magnetic circuit breaker from the EasyPact EZC100F series, rated 16 A at 40 °C (16 A at 50 °C with the TM-D trip unit). It carries a 25 kA Icu breaking capacity at 220–240 V AC 50/60 Hz per IEC 60947-2, and is suitable for isolation per that same standard. The kit includes the breaker with front-connect terminals, toggle control, and positive contact indication — no earth-leakage module or neutral protection built in, so plan for those separately if the circuit requires them. At 380–415 V AC the rating drops to 10 kA Icu, and at 440 V AC to 7.5 kA Icu. For DC circuits, it manages 5 kA at 125 V DC (1-pole) or 250 V DC (2-pole). The 'F' breaking capacity code tells you this is the standard (not high-performance) variant in the EZC100 family — if your available fault current exceeds these numbers, step up to the 'N' or 'H' code. Mounts to a backplate via fixed screws (not DIN rail). Connection pitch is 25 mm. IP20 finger-safe terminals; IK07 impact resistance.","metaTitle":"Schneider EasyPact EZC100F3016 Circuit Breaker, 16 A, 25 kA","metaDescription":"Schneider Electric EasyPact EZC100F3016 3-pole thermal-magnetic circuit breaker, 16 A rated current, 25 kA breaking capacity at 240 V AC. IEC 60947-2. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"60 mm","Width":"75 mm","Height":"130 mm","Voltage":"550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2","IP Rating":"IP20","Application":"Distribution","Control Type":"Toggle","Product Status":"Active","Terminal Pitch":"25 mm","Trip Unit Type":"Thermal-magnetic","Pollution Degree":"3 conforming to IEC 60947","Temp Storage Max":"85 °C","Temp Storage Min":"-35 °C","Breaking Capacity":"25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2","Insulation Voltage Ui":"690 V AC 50/60 Hz conforming to IEC 60947-2","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-35...85 °C","Connection Surface Top":"Front","Mechanical Life Cycles":"13000 cycles","Connection Surface Bottom":"Front","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f30acbc5b2ec9452376f2dc3cb705330.pdf","sourceUrl":"https://www.se.com/ng/en/product/EZC100F3016/circuit-breakereasypact-ezc100f-tmd-16a-3-poles-3d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/EZC100F3016/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZC100F3016","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZC100F3016 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}