{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZC100F3032","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZC100F3032","canonicalUrl":"https://aoctrl.com/schneider/EZC100F3032","factsUrl":"https://aoctrl.com/api/mcp/products/EZC100F3032","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZC100F, circuit breaker, 3P, 32 A, TM-D trip unit, 25 kA Icu at 240 V AC, IEC 60947-2.","salesMarkdown":"The EZC100F3032 is a 3-pole EasyPact EZC100F circuit breaker from Schneider, rated 32 A at 40 °C (32 A at 50 °C on the trip unit) with a thermal-magnetic TM-D trip unit. The F breaking capacity code tells you it's the high-interrupting version of the EZC100 frame. That means it's fine on 480Y/277 V or 400 V three-phase systems, and the DC rating lets it switch 250 V DC loads (2-pole series) for battery or UPS circuits. The 3t protected poles with no neutral protection mean this is a straight 3-pole breaker — no switched neutral, no 4-pole option on this variant. IP20 finger-safe terminals and IK07 impact resistance (2 J) mean it's protected against accidental contact and light mechanical shock inside a panel. Pollution degree 3 per IEC 60947 handles conductive dust and condensation typical in industrial enclosures. The toggle control gives positive contact indication — you can see and feel the contact position. Fixed backplate mounting, not DIN rail. The 25 mm pitch matches common busbar and terminal-block layouts. Mechanical durability is 13,000 cycles — that's the expected life under normal switching. For a distribution breaker that sees occasional manual switching and fault clearing, that's plenty. If you're cycling it daily as a disconnect, consider a switch-disconnect instead. Also carries JIS C8201-2-2 for the Japanese market.","metaTitle":"Schneider Electric EZC100F3032 EasyPact EZC100F 32A 3P Circu","metaDescription":"Schneider Electric EZC100F3032 EasyPact EZC100F 32A 3P circuit breaker. 25 kA Icu at 240 V AC, thermal-magnetic TM-D trip unit. IEC 60947-2. Sourced to order against an RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"60 mm","Width":"75 mm","Height":"130 mm","Standards":"GB/T 14048.2 EN/IEC 60947-2 EN/IEC 60947-1 JIS C8201-2-2","Control type":"Toggle","Network type":"DC AC","Mounting mode":"Fixed","Trip unit name":"TM-D","Protection type":"Overload protection Short-circuit protection","lifecycle_stage":"current","Connection pitch":"25 mm","Local signalling":"Positive contact indication","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60947","Range of product":"EasyPact","Trip unit rating":"32 A at 50 °C","Breaking capacity":"25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"Easypact EZC100F","Network frequency":"50/60 Hz","Poles description":"3P","Upside connection":"Front","Device application":"Distribution","[In] rated current":"32 A at 40 °C","Downside connection":"Front","Circuit breaker name":"Easypact EZC100F","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Mechanical durability":"13000 cycles","Breaking capacity code":"F","IK degree of protection":"IK07 conforming to EN 50102","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Neutral protection setting":"Without protection","Protected poles description":"3t","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2","Ambient air temperature for storage":"-35...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 3.75 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$45.84","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/55f4f546708a4ac7d4ab9bf0e4b353d5.pdf","sourceUrl":"https://www.se.com/vn/en/product/EZC100F3032/circuit-breakereasypact-ezc100f-tmd-32a-3-poles-3d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/EZC100F3032/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy EZC100F3032?","answer":"We source this part to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is EZC100F3032's breaking capacity at 240 V?","answer":"25 kA Icu at 220...240 V AC 50/60 Hz per IEC 60947-2. At 380...415 V it drops to 10 kA, and at 440 V to 7.5 kA. The DC rating is 5 kA at 125 V DC (1P) or 250 V DC (2P)."},{"question":"What standards does EZC100F3032 comply with?","answer":"EN/IEC 60947-2, GB/T 14048.2, and JIS C8201-2-2. It is also suitable for isolation per IEC 60947-2."},{"question":"What is the closest alternative to EZC100F3032 in the same family?","answer":"Within the EasyPact EZC100F frame, the main variant differences are trip rating and pole count. A 3-pole 40 A version (EZC100F3040) shares the same footprint, breaking capacity, and TM-D trip technology — just a higher current setting. No pin-compatible alternative exists outside the EZC100 series."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZC100F3032","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZC100F3032 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}