{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZC100F3063","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZC100F3063","canonicalUrl":"https://aoctrl.com/schneider/EZC100F3063","factsUrl":"https://aoctrl.com/api/mcp/products/EZC100F3063","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZC100F, EZC100F3063, 3-pole MCCB, 63 A thermal-magnetic trip unit, 25 kA Icu at 240 V AC, IP20.","salesMarkdown":"The Schneider Electric EZC100F3063 is a 3-pole EasyPact EZC100F moulded-case circuit breaker with a thermal-magnetic TM-D trip unit rated 63 A at 50 °C. The thermal-magnetic trip gives you an inverse-time overload curve (the thermal bimetal) plus instantaneous magnetic short-circuit protection, so it covers both sustained overloads and hard faults in one compact package. Breaking capacity is where this breaker earns its keep in a distribution panel. Drop to 380–415 V AC and it still handles 10 kA; at 440 V AC it holds 7.5 kA; at 550 V AC it manages 5 kA. On the DC side, it breaks 5 kA at 125 V DC (1-pole) and 5 kA at 250 V DC (2-pole). For a 63 A feeder in a 400 V panel with a typical transformer impedance, 10 kA is usually enough headroom — but if your upstream transformer is oversized or your fault current study shows higher, check the 25 kA 240 V number against your service-entrance rating. ## Mounting and enclosure fit This breaker mounts fixed to a backplate, not on a DIN rail. That is typical for Moulded-Case Circuit Breakers (MCCBs) in this frame size — you bolt it to the panel's mounting plate, torque the terminals to spec, and wire front-to-front. The 25 mm connection pitch spaces the phase terminals evenly, which keeps busbar and cable-lug alignment predictable. IP20 finger-safe protection means the front face is touch-safe when the cover is on; IK07 impact resistance handles the odd dropped tool during commissioning. ## Standards and approvals — what they certify It also carries GB/T 14048.2 (China) and JIS C8201-2-2 (Japan) marks, so it is accepted across major global markets without a separate re-certification. Lifecycle status is current production. No EOL notice or last-time-buy on record. This is a standard catalogue item in Schneider's EasyPact range, so it is not a niche or legacy SKU that might vanish on short notice.","metaTitle":"Schneider Electric EZC100F3063 EasyPact EZC100F, 63 A, 25 kA","metaDescription":"Schneider Electric EZC100F3063 EasyPact EZC100F MCCB, 63 A thermal-magnetic, 25 kA Icu at 240 V AC. EN/IEC 60947-2, IP20. Sourced to order against an RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"60 mm","Width":"75 mm","Height":"130 mm","Voltage":"550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2","IP Rating":"IP20","Application":"Distribution","Control Type":"Toggle","Network Type":"DC AC","Product Status":"Active","Terminal Pitch":"25 mm","Trip Unit Type":"Thermal-magnetic","Pollution Degree":"3 conforming to IEC 60947","Temp Storage Max":"85 °C","Temp Storage Min":"-35 °C","Breaking Capacity":"25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2","Insulation Voltage Ui":"690 V AC 50/60 Hz conforming to IEC 60947-2","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-35...85 °C","Connection Surface Top":"Front","Mechanical Life Cycles":"13000 cycles","Connection Surface Bottom":"Front","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$45.84","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3c750bd95525a5442e2ddfec3bd75df3.pdf","sourceUrl":"https://www.se.com/ng/en/product/EZC100F3063/circuit-breaker-easypact-ezc100f-tmd-63-a-3-poles-3d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/EZC100F3063/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZC100F3063","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZC100F3063 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}