{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZC100H1015","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZC100H1015","canonicalUrl":"https://aoctrl.com/schneider/EZC100H1015","factsUrl":"https://aoctrl.com/api/mcp/products/EZC100H1015","rawCanonicalId":null},"summary":{"shortDescription":"Schneider EZC100H1015 Easypact Ezc — now discontinued. Supplied from remaining channel stock; full specifications, lifecycle and same-series options are below.","salesMarkdown":"## Overview The EZC100H1015 is a Schneider EasyPact EZC100H series 1-pole circuit breaker with a TM-D thermal-magnetic trip unit rated 15 A at 50 °C. It operates on 125 V DC/AC at 60 Hz and is fixed-mounted with IP20 finger-safe protection. The breaker provides short-circuit and overload protection for distribution applications and carries an H-class breaking capacity. It is an active, in-production part. ## Alternatives & selection Compared to the 4-pole EZC100H4016 (16 A, 550 V), the EZC100H1015 uses a single pole and a lower 125 V supply, making it suitable for single-phase or DC branch circuits rather than three-phase distribution. The 15 A trip rating versus 16 A is a minor difference, but the pole count and voltage rating are the primary selection gates — the EZC100H1015 cannot replace a 4-pole breaker in a three-phase panel without rewiring.","metaTitle":"Schneider EZC100H1015 EasyPact EZC circuit breaker, 1-pole, 15 A, 125 V DC/AC","metaDescription":"Schneider EasyPact EZC100H1015 circuit breaker, 1-pole, TM-D trip unit, 15 A at 50 °C, 125 V DC/AC, IP20, fixed mount. Active product.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"60 mm","Width":"25 mm","Height":"130 mm","Voltage":"125 V DC conforming to IEC 60947-2 415 V AC 50/60 Hz conforming to IEC 60947-2","IP Rating":"IP20","Application":"Distribution","Control Type":"Toggle","Network Type":"DC AC","Product Status":"Active","Terminal Pitch":"25 mm","Trip Unit Type":"Thermal-magnetic","Pollution Degree":"3 conforming to IEC 60664-1 3 conforming to IEC 947-1","Temp Storage Max":"85 °C","Temp Storage Min":"-35 °C","Breaking Capacity":"10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2","Insulation Voltage Ui":"690 V AC 50/60 Hz conforming to IEC 60947-2","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-35...85 °C","Connection Surface Top":"Front","Mechanical Life Cycles":"13000 cycles","Connection Surface Bottom":"Front","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$35.67","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/51e59a4c6ed6daa1caf9bb2286b16ece.pdf","sourceUrl":"https://www.se.com/ae/en/product/EZC100H1015/circuit-breaker-easypact-ezc100h-tmd-15-a-1-pole-1d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/EZC100H1015/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZC100H1015","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZC100H1015 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}