{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZC100H1040","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZC100H1040","canonicalUrl":"https://aoctrl.com/schneider/EZC100H1040","factsUrl":"https://aoctrl.com/api/mcp/products/EZC100H1040","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZC100H, 1-pole thermal-magnetic circuit breaker, 40 A at 50 °C, TM-D trip unit, 25 kA Icu at 240 V AC, IP20, backplate mount.","salesMarkdown":"## What this breaker does on the line The Schneider Electric EZC100H1040 is a 1-pole thermal-magnetic circuit breaker from the EasyPact EZC100H series, rated 40 A at 50 °C (TM-D trip unit). It's built for distribution applications where you need short-circuit and overload protection in a single-pole format — think lighting panels, small transformers, control circuit feeds. The 25 mm width per pole keeps the rail density high. At 125 V DC (1-pole) it's rated 10 kA Icu. The 'H' breaking capacity code tells you this is the higher-interrupting variant in the EZC100 family; the standard version would be lower. Fixed backplate mount — no DIN rail adapter on this one, so plan for a drilled panel or a sub-plate. Front connections both top and bottom, with a toggle actuator and positive contact indication so you can see the state without opening the panel. Designed and tested to IEC 60947-2, plus JIS C8201-2-2 and GB/T 14048.2 (Chinese GB standard). Rated insulation voltage 690 V AC, operational voltage up to 415 V AC or 125 V DC. Pollution degree 3, which covers industrial environments with conductive pollution. No earth-leakage protection built in; that's a separate module.","metaTitle":"Schneider Electric EZC100H1040 EasyPact EZC100H 1P 40A Therm","metaDescription":"Schneider Electric EZC100H1040 EasyPact EZC100H 1-pole circuit breaker, 40 A TM-D trip unit, 25 kA Icu at 240 V AC. Complies with IEC 60947-2. Sourced to order against an RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"60 mm","Width":"25 mm","title":"EZC100H1040","Height":"130 mm","Standards":"JIS C8201-2-2 EN/IEC 60947-1 GB/T 14048.2 EN/IEC 60947-2","description":"circuit breaker Easypact EZC100H - TMD - 40 A - 1 pole 1d","Control type":"Toggle","Network type":"DC AC","Mounting mode":"Fixed","Trip unit name":"TM-D","Protection type":"Short-circuit protection Overload protection","lifecycle_stage":"current","Connection pitch":"25 mm","Local signalling":"Positive contact indication","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60664-1 3 conforming to IEC 947-1","Range of product":"EasyPact","Trip unit rating":"40 A at 50 °C","Breaking capacity":"10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"Easypact EZC100H","Network frequency":"50/60 Hz","Poles description":"1P","Upside connection":"Front","Device application":"Distribution","[In] rated current":"40 A at 40 °C","Downside connection":"Front","Circuit breaker name":"Easypact EZC100H","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Mechanical durability":"13000 cycles","Breaking capacity code":"H","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Neutral protection setting":"Without protection","Protected poles description":"1t","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"125 V DC conforming to IEC 60947-2 415 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-35...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"5 kA at 125 V DC conforming to IEC 60947-2 12.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$47.02","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c8cc3ee972048a266606df04f7b4c7bb.pdf","sourceUrl":"https://www.se.com/ae/en/product/EZC100H1040/circuit-breaker-easypact-ezc100h-tmd-40-a-1-pole-1d/"},"ai":{"faq":[{"question":"What is EZC100H1040's listed depth?","answer":"The listed depth is 60 mm."},{"question":"What is EZC100H1040's listed width?","answer":"The listed width is 25 mm."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZC100H1040","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZC100H1040 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}