{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZC100H1060","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZC100H1060","canonicalUrl":"https://aoctrl.com/schneider/EZC100H1060","factsUrl":"https://aoctrl.com/api/mcp/products/EZC100H1060","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZC100H1060, 1-pole thermal-magnetic MCCB, 60 A rated current, 25 kA breaking capacity at 240 V AC, IEC 60947-2.","salesMarkdown":"The Schneider Electric EasyPact EZC100H1060 is a 1-pole thermal-magnetic molded-case circuit breaker rated 60 A, built to IEC 60947-2 for distribution duty. It sits in the EasyPact range, which is Schneider's value line for commercial and light industrial panels where you need a reliable MCCB without the premium of a Compact NSX. The TM-D trip unit gives you fixed thermal and magnetic protection — set it and forget it, no adjustment dials. At 60 A and 1 pole, this is a single-phase feeder or branch breaker. The 25 kA breaking capacity at 220–240 V AC covers most North American commercial panel fault levels; the 5 kA at 400–415 V AC is enough for European 400 V three-phase systems where you'd use three of these (one per phase) on a sub-distribution board. The 50 kA at 110–130 V AC is overkill for most jobs but means it handles high-fault utility drops without cascading. The Icu (ultimate breaking capacity) varies by voltage because arc extinction gets harder as voltage rises. At 240 V AC you get 25 kA — that's the typical short-circuit rating for a 225 A panelboard feeder. At 415 V AC the same breaker drops to 5 kA, which is still adequate for most European distribution boards where the transformer impedance limits fault current below that. The 10 kA at 125 V DC is useful for battery-bank or UPS output circuits. If you need selectivity (keeping the upstream breaker closed while the downstream clears a fault), you step up to a Category B MCCB like the Compact NSX. For a simple radial feed, Category A is fine and saves panel space. The EZC100H1060 is in active current production. No end-of-life notice has been issued for the EasyPact EZC100H range as of the latest data. Fixed mounting on a backplate, 25 mm width per pole. Front connection top and bottom — standard for panelboard plug-on or bus-bar stabs. IP20 finger-safe terminals, IK07 impact rating. ## Temperature derating — the real-world gotcha If your panel sits in a hot machine room or near a furnace, you don't need to derate this breaker until you exceed 50 °C. Below -25 °C the thermal trip may be sluggish, but that's rare in indoor distribution. Compliant with IEC 60947-2 (the main MCCB standard globally), JIS C8201-2-2 (Japanese industrial standard), and GB/T 14048.2 (Chinese GB standard). Rated insulation voltage 690 V AC, so it's fine on 400/480 V systems with margin. No earth-leakage protection built in; if you need RCD functionality, add an external Vigi module or use the EZC100H with earth-leakage option.","metaTitle":"Schneider EasyPact EZC100H1060 60A 1P MCCB, 25kA at 240V","metaDescription":"Schneider Electric EasyPact EZC100H1060 60A thermal-magnetic MCCB, 1-pole, 25kA breaking capacity at 240V AC. Active production, sourced to order. Quoted on request.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"60 mm","Width":"25 mm","Height":"130 mm","Voltage":"125 V DC conforming to IEC 60947-2 415 V AC 50/60 Hz conforming to IEC 60947-2","IP Rating":"IP20","Application":"Distribution","Control Type":"Toggle","Product Status":"Active","Terminal Pitch":"25 mm","Trip Unit Type":"Thermal-magnetic","Pollution Degree":"3 conforming to IEC 60664-1 3 conforming to IEC 947-1","Temp Storage Max":"85 °C","Temp Storage Min":"-35 °C","Breaking Capacity":"10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2","Insulation Voltage Ui":"690 V AC 50/60 Hz conforming to IEC 60947-2","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-35...85 °C","Connection Surface Top":"Front","Mechanical Life Cycles":"13000 cycles","Connection Surface Bottom":"Front","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$47.02","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1f38e49301691e5eb5bbac9cc9289304.pdf","sourceUrl":"https://www.se.com/ph/en/product/EZC100H1060/circuit-breaker-easypact-ezc100h-tmd-60-a-1-pole-1d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/EZC100H1060/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZC100H1060","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZC100H1060 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}