{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZC100H2030","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZC100H2030","canonicalUrl":"https://aoctrl.com/schneider/EZC100H2030","factsUrl":"https://aoctrl.com/api/mcp/products/EZC100H2030","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZC100H series, EZC100H2030, 2-pole molded case circuit breaker, 30 A rated current, thermal-magnetic TM-D trip unit, 10–100 kA breaking capacity per IEC 60947-2, toggle control, IP20, backplate mount.","salesMarkdown":"The Schneider Electric EasyPact EZC100H2030 is a 2-pole molded case circuit breaker (MCCB) rated 30 A at 40 °C, with a thermal-magnetic TM-D trip unit providing overload and short-circuit protection per IEC 60947-2. It carries a Category A utilization class, meaning it is not intended for current-limiting applications but for standard distribution branch protection. The H breaking capacity code delivers 10 kA Icu at 125 V DC (1P) up to 100 kA Icu at 110–130 V AC — the 30 kA Icu at 400–415 V AC is the figure most relevant for European 400 V distribution panels. Fixed backplate mounting, no DIN-rail clip — plan for screw-fixing onto the panel backplate. Connection pitch is 25 mm, matching standard busbar spacing for 2-pole distribution blocks. IP20 finger-safe enclosure is adequate for enclosed panels but not for open washdown areas. Compliant with EN/IEC 60947-1 and EN/IEC 60947-2, plus GB/T 14048.2 and JIS C8201-2-2.","metaTitle":"Schneider Electric EZC100H2030 EasyPact EZC100H 30A 2P Molde","metaDescription":"Schneider Electric EZC100H2030 EasyPact EZC100H 2-pole MCCB, 30 A rated current, thermal-magnetic TM-D trip unit, 10-100 kA breaking capacity per IEC 60947-2. Currently in producti","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"60 mm","Width":"50 mm","Height":"130 mm","Voltage":"550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2","IP Rating":"IP20","Application":"Distribution","Control Type":"Toggle","Network Type":"DC AC","Product Status":"Active","Terminal Pitch":"25 mm","Trip Unit Type":"Thermal-magnetic","Pollution Degree":"3 conforming to IEC 60664-1 3 conforming to IEC 947-1","Temp Storage Max":"85 °C","Temp Storage Min":"-35 °C","Breaking Capacity":"10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2","Insulation Voltage Ui":"690 V AC 50/60 Hz conforming to IEC 60947-2","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-35...85 °C","Connection Surface Top":"Front","Mechanical Life Cycles":"13000 cycles","Connection Surface Bottom":"Front","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$52.89","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/21f67d1ccc9c2b50c5185a085164c127.pdf","sourceUrl":"https://www.se.com/ae/en/product/EZC100H2030/circuit-breaker-easypact-ezc100h-tmd-30-a-2-poles-2d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/EZC100H2030/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZC100H2030","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZC100H2030 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}