{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZC100H2063","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZC100H2063","canonicalUrl":"https://aoctrl.com/schneider/EZC100H2063","factsUrl":"https://aoctrl.com/api/mcp/products/EZC100H2063","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZC100H, 2-pole MCCB, 63 A, thermal-magnetic TM-D trip unit, 30 kA Icu at 400 V AC, 10 kA Icu at 125 V DC, IP20, backplate mount.","salesMarkdown":"The Schneider Electric EZC100H2063 is a 2-pole EasyPact EZC100H moulded-case circuit breaker (MCCB) rated 63 A at 40 °C, with a thermal-magnetic TM-D trip unit that provides overload and short-circuit protection in one package. It is a Category A breaker (no intentional short-time delay), sized for distribution panels and feeder circuits where you need a compact, fixed-mount device with front connections. The 63 A rating at 50 °C and 63 A at 40 °C mean the trip unit is calibrated for continuous current at those ambient temperatures — derate above 50 °C per the thermal curve. The TM-D trip is a fixed thermal-magnetic design; you don't swap rating plugs, you select the breaker for the load. ## Breaking capacity — what the H code means The H breaking capacity code delivers 30 kA Icu at 380…400 V AC and 50 kA Icu at 220…240 V AC. At 440 V AC it holds 20 kA Icu. At 125 V DC single-pole it still clears 10 kA, useful for battery or rectifier circuits. The 100 kA Icu at 110…130 V AC is a high-interrupting rating for low-voltage, high-fault-current scenarios — think large step-down transformers or UPS bypass circuits. Fixed backplate mount with front connections — the breaker bolts to a panel backplate, and cables land on the front terminals. Connection pitch is 25 mm, which matches standard busbar or cable-lug spacing for 63 A class. The IP20 finger-safe enclosure and IK07 impact resistance mean it survives handling in a panel environment without enclosure damage. Pollution degree 3 per IEC 60947 — rated for conductive pollution in industrial enclosures where occasional condensation occurs. That is the default for most control panels; no special conformal coating needed.","metaTitle":"Schneider Electric EZC100H2063 EasyPact EZC100H, 63 A, 2-Pol","metaDescription":"Schneider Electric EZC100H2063 EasyPact EZC100H circuit breaker, 63 A, 2-pole, thermal-magnetic TM-D trip unit, 30 kA Icu at 400 V AC. Active production, available to order. Quoted","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"60 mm","Width":"50 mm","Height":"130 mm","Voltage":"550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2","IP Rating":"IP20","Application":"Distribution","Control Type":"Toggle","Network Type":"DC AC","Product Status":"Active","Terminal Pitch":"25 mm","Trip Unit Type":"Thermal-magnetic","Pollution Degree":"3 conforming to IEC 60947","Temp Storage Max":"85 °C","Temp Storage Min":"-35 °C","Breaking Capacity":"10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2","Insulation Voltage Ui":"690 V AC 50/60 Hz conforming to IEC 60947-2","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-35...85 °C","Connection Surface Top":"Front","Mechanical Life Cycles":"13000 cycles","Connection Surface Bottom":"Front","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$52.89","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4c56c165a00107882608ef2da8f82d4a.pdf","sourceUrl":"https://www.se.com/ae/en/product/EZC100H2063/circuit-breaker-easypact-ezc100h-tmd-63-a-2-poles-2d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/EZC100H2063/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZC100H2063","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZC100H2063 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}