{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZC100H2100","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZC100H2100","canonicalUrl":"https://aoctrl.com/schneider/EZC100H2100","factsUrl":"https://aoctrl.com/api/mcp/products/EZC100H2100","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZC100H, 2-pole molded case circuit breaker, 100 A rated current, TM-D thermal-magnetic trip unit, H breaking capacity class, front connection.","salesMarkdown":"The Schneider Electric EZC100H2100 is a 2-pole molded case circuit breaker (MCCB) from the EasyPact EZC100H series, rated 100 A at 40 °C with a TM-D thermal-magnetic trip unit that provides overload and short-circuit protection in a single compact package. Its H breaking capacity class delivers 10 kA Icu at 125 V DC (1P), 10 kA at 250 V DC (2P), 10 kA at 550 V AC, 20 kA at 440 V AC, 30 kA at 400–415 V AC, 50 kA at 220–240 V AC, and 100 kA at 110–130 V AC — all per IEC 60947-2, so the same breaker covers a wide range of fault levels across global supply voltages. ## Standards and environment Designed to EN/IEC 60947-1, GB/T 14048.2, JIS C8201-2-2, and EN/IEC 60947-2 — covering global industrial control and switchgear requirements for distribution applications. Operates from -25 °C to 70 °C and stores from -35 °C to 85 °C; pollution degree 3 per IEC 60664-1 (conductive pollution or dry non-conductive that becomes conductive) — typical for factory-floor panel environments. Mechanical durability rated at 13,000 cycles, utilisation category A (non-frequent switching), and no integrated earth-leakage or neutral protection — those are external add-ons.","metaTitle":"Schneider Electric EZC100H2100 EasyPact EZC100H 2P 100A MCCB","metaDescription":"Schneider Electric EZC100H2100 EasyPact EZC100H 2-pole MCCB, 100A rated at 40°C, TM-D trip. Breaking capacity 10-100kA AC/DC. Sourced to order against RFQ. Active lifecycle.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"60 mm","Width":"50 mm","title":"EZC100H2100","Height":"130 mm","Standards":"EN/IEC 60947-1 GB/T 14048.2 JIS C8201-2-2 EN/IEC 60947-2","description":"circuit breaker Easypact EZC100H - TMD - 100 A - 2 poles 2d","Control type":"Toggle","Network type":"AC DC","Mounting mode":"Fixed","Trip unit name":"TM-D","Protection type":"Overload protection Short-circuit protection","lifecycle_stage":"current","Connection pitch":"25 mm","Local signalling":"Positive contact indication","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60664-1 3 conforming to IEC 947-1","Range of product":"EasyPact","Trip unit rating":"100 A at 50 °C","Breaking capacity":"10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"Easypact EZC100H","Network frequency":"50/60 Hz","Poles description":"2P","Upside connection":"Front","Device application":"Distribution","[In] rated current":"100 A at 40 °C","Downside connection":"Front","Circuit breaker name":"Easypact EZC100H","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Mechanical durability":"13000 cycles","Breaking capacity code":"H","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Neutral protection setting":"Without protection","Protected poles description":"2t","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2","Ambient air temperature for storage":"-35...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"15 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 125 V DC conforming to IEC 60947-2 5 kA at 250 V DC conforming to IEC 60947-2 50 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b1ffed4f7d54d7e0edbaad2fb9b42630.pdf","sourceUrl":"https://www.se.com/ph/en/product/EZC100H2100/circuit-breaker-easypact-ezc100h-tmd-100-a-2-poles-2d/"},"ai":{"faq":[{"question":"What is EZC100H2100's breaking capacity at 400 V AC?","answer":"At 400–415 V AC 50/60 Hz the EZC100H2100 delivers 30 kA Icu per IEC 60947-2."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZC100H2100","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZC100H2100 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}