{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZC100H4025","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZC100H4025","canonicalUrl":"https://aoctrl.com/schneider/EZC100H4025","factsUrl":"https://aoctrl.com/api/mcp/products/EZC100H4025","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZC100H, 25 A, 4-pole MCCB, thermal-magnetic TM-D trip unit, 30 kA Icu at 400 V AC, IP20, backplate mount.","salesMarkdown":"The Schneider Electric EZC100H4025 is a 4-pole moulded-case circuit breaker from the EasyPact EZC100H series, rated 25 A at 40 °C with a thermal-magnetic TM-D trip unit. It is built for distribution applications — think panel feeder protection, sub-distribution boards, or main breakers in smaller commercial and industrial switchboards. The 30 kA Icu at 400 V AC (IEC 60947-2) gives it enough interrupting capacity for most low-voltage distribution systems without needing a current-limiting upstream breaker. ## Breaking capacity — what each voltage rating means for your system The EZC100H4025 carries multiple Icu ratings across its voltage range, and the right one governs your installation's available fault current. At 220–240 V AC it handles 50 kA; at 380–400 V AC it is 30 kA; at 440 V AC it drops to 20 kA; and at 550 V AC it is 10 kA. For DC circuits, it manages 10 kA at 125 V DC (1-pole) or 250 V DC (2-pole). The 30 kA at 400 V is the most common spec for European-style 400/230 V distribution — it means this breaker can be installed at a point where the prospective short-circuit current does not exceed 30 kA without needing an upstream current-limiting device. The H breaking capacity code indicates the high-interrupting version of the EZC100 frame. This breaker mounts fixed to a backplate — no DIN-rail adapter, so plan for drilled and tapped mounting points or a dedicated panel cut-out. The front-facing connections (both line and load) simplify busbar or cable routing in a dead-front panel. Connection pitch is 25 mm, which matches standard distribution busbar spacing. The IP20 finger-safe enclosure is fine for enclosed switchboards but not for washdown areas. The IK07 impact rating means it survives the odd dropped tool during panel assembly.","metaTitle":"EZC100H4025 EasyPact EZC100H 25A 4P MCCB, 30kA at 400V","metaDescription":"Schneider Electric EZC100H4025 EasyPact EZC100H 25A 4-pole MCCB. 30 kA Icu at 400 V AC, thermal-magnetic TM-D trip. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"60 mm","Width":"100 mm","Height":"130 mm","Voltage":"550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2","IP Rating":"IP20","Application":"Distribution","Control Type":"Toggle","Network Type":"DC AC","Product Status":"Active","Terminal Pitch":"25 mm","Trip Unit Type":"Thermal-magnetic","Pollution Degree":"3 conforming to IEC 60947","Temp Storage Max":"85 °C","Temp Storage Min":"-35 °C","Breaking Capacity":"10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2","Insulation Voltage Ui":"690 V AC 50/60 Hz conforming to IEC 60947-2","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-35...85 °C","Connection Surface Top":"Front","Mechanical Life Cycles":"13000 cycles","Connection Surface Bottom":"Front","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$76.41","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/8fa7cf34bc8b2a931dc93f3e8a900f1a.pdf","sourceUrl":"https://www.se.com/ph/en/product/EZC100H4025/circuit-breaker-easypact-ezc100h-tmd-25-a-4-poles-3d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/EZC100H4025/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZC100H4025","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZC100H4025 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}