{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZC100H4060","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZC100H4060","canonicalUrl":"https://aoctrl.com/schneider/EZC100H4060","factsUrl":"https://aoctrl.com/api/mcp/products/EZC100H4060","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZC100H, EZC100H4060, 4-pole circuit breaker, 60 A, TM-D thermal-magnetic trip unit, 10-100 kA breaking capacity, IEC 60947-2.","salesMarkdown":"The Schneider Electric EZC100H4060 is a 4-pole EasyPact EZC100H moulded-case circuit breaker rated 60 A at 40 °C, with a TM-D thermal-magnetic trip unit that provides both overload and short-circuit protection in one device. Breaking capacity varies by voltage: 100 kA Icu at 110-130 V AC, 50 kA at 220-240 V AC, 30 kA at 380-400 V AC, 20 kA at 440 V AC, 10 kA at 550 V AC, and 10 kA at 125 V DC / 250 V DC. The 'H' breaking capacity code indicates the high-interrupting version of the EZC100H family. The breaker carries approvals to EN/IEC 60947-2, GB/T 14048.2, EN/IEC 60947-1, and JIS C8201-2-2. It is rated IK07 for mechanical impact resistance and IP20 for finger-safe terminal protection. ## Integration notes Mounts fixed to a backplate (not DIN rail). Dimensions are 130 mm high, 100 mm wide, 60 mm deep. Connection pitch is 25 mm. Both line and load connections are on the front face, simplifying busbar and cable routing in a panel layout. The TM-D trip unit is rated 60 A at 50 °C; the breaker's continuous current rating is 60 A at 40 °C. Mechanical endurance is 13,000 cycles. Toggle control with positive contact indication gives a clear visual of contact position. Three poles are protected (3t); the fourth pole is switched but not protected — no neutral protection is fitted.","metaTitle":"Schneider Electric EZC100H4060 EasyPact EZC100H Circuit Brea","metaDescription":"Schneider Electric EZC100H4060 EasyPact EZC100H 4-pole circuit breaker, 60 A thermal-magnetic TM-D trip unit, 10-100 kA breaking capacity per IEC 60947-2. Available to order; confi","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"60 mm","Width":"100 mm","title":"EZC100H4060","Height":"130 mm","Standards":"EN/IEC 60947-2 GB/T 14048.2 EN/IEC 60947-1 JIS C8201-2-2","description":"circuit breaker Easypact EZC100H - TMD - 60 A - 4 poles 3d","Control type":"Toggle","Network type":"DC AC","Mounting mode":"Fixed","Trip unit name":"TM-D","Protection type":"Short-circuit protection Overload protection","lifecycle_stage":"current","Connection pitch":"25 mm","Local signalling":"Positive contact indication","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60947","Range of product":"EasyPact","Trip unit rating":"60 A at 50 °C","Breaking capacity":"10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"Easypact EZC100H","Network frequency":"50/60 Hz","Poles description":"4P","Upside connection":"Front","Device application":"Distribution","[In] rated current":"60 A at 40 °C","Downside connection":"Front","Circuit breaker name":"Easypact EZC100H","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Mechanical durability":"13000 cycles","Breaking capacity code":"H","IK degree of protection":"IK07 conforming to EN 50102","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Neutral protection setting":"Without protection","Protected poles description":"3t","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2","Ambient air temperature for storage":"-35...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"5 kA at 125 V DC conforming to IEC 60947-2 5 kA at 250 V DC conforming to IEC 60947-2 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 415 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$76.41","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/443939cd9adfae3fb00ac619052271fe.pdf","sourceUrl":"https://www.se.com/ph/en/product/EZC100H4060/circuit-breaker-easypact-ezc100h-tmd-60-a-4-poles-3d/"},"ai":{"faq":[{"question":"What is the breaking capacity of the EZC100H4060?","answer":"Breaking capacity varies by voltage: 100 kA Icu at 110-130 V AC, 50 kA at 220-240 V AC, 30 kA at 380-400 V AC, 20 kA at 440 V AC, 10 kA at 550 V AC, and 10 kA at 125 V DC or 250 V DC, all per IEC 60947-2."},{"question":"Where can I buy the EZC100H4060?","answer":"The EZC100H4060 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What compliance standards does the EZC100H4060 meet?","answer":"The breaker complies with EN/IEC 60947-2, GB/T 14048.2, EN/IEC 60947-1, and JIS C8201-2-2. It is rated IP20 for finger protection and IK07 for impact resistance."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZC100H4060","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZC100H4060 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}