{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZC100H4075","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZC100H4075","canonicalUrl":"https://aoctrl.com/schneider/EZC100H4075","factsUrl":"https://aoctrl.com/api/mcp/products/EZC100H4075","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZC100H, 4-pole MCCB, 75 A TM-D trip, 30 kA Icu at 400 V AC, thermal-magnetic, front-connected, toggle control.","salesMarkdown":"## What the 30 kA at 400 V means for your panel At 220–240 V AC that figure rises to 50 kA Icu, and at 110–130 V AC it reaches 100 kA Icu, all certified to IEC 60947-2. For DC circuits it delivers 10 kA Icu at 125 V DC (1-pole) or 250 V DC (2-pole). That spread covers most distribution panels in light industrial and commercial buildings where the transformer impedance keeps prospective fault current under 30 kA. ## Integration — panel fit and connection The breaker mounts to a backplate (fixed mounting, not DIN rail) with a 25 mm connection pitch. Both line and load connections are front-accessed, so it panels into a standard distribution board without rear-bus adaptors. Dimensions are 100 mm wide × 130 mm high × 60 mm deep — a 4-pole MCCB that fits a 100 mm module slot. ## Trip unit and protection — what the TM-D does Mechanical durability is rated at 13,000 cycles — typical for a distribution MCCB that sees infrequent switching.","metaTitle":"Schneider Electric EZC100H4075 EasyPact EZC100H 75A 4P MCCB,","metaDescription":"Schneider Electric EZC100H4075 EasyPact EZC100H 4-pole MCCB, 75A thermal-magnetic TM-D trip unit. 30 kA Icu at 400 V AC. IEC 60947-2. Currently in production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"60 mm","Width":"100 mm","Height":"130 mm","Standards":"JIS C8201-2-2 EN/IEC 60947-2 EN/IEC 60947-1 GB/T 14048.2","Control type":"Toggle","Network type":"DC AC","Mounting mode":"Fixed","Trip unit name":"TM-D","Protection type":"Overload protection Short-circuit protection","lifecycle_stage":"current","Connection pitch":"25 mm","Local signalling":"Positive contact indication","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60947","Range of product":"EasyPact","Trip unit rating":"75 A at 50 °C","Breaking capacity":"10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"Easypact EZC100H","Network frequency":"50/60 Hz","Poles description":"4P","Upside connection":"Front","Device application":"Distribution","[In] rated current":"75 A at 40 °C","Downside connection":"Front","Circuit breaker name":"Easypact EZC100H","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Mechanical durability":"13000 cycles","Breaking capacity code":"H","IK degree of protection":"IK07 conforming to EN 50102","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Neutral protection setting":"Without protection","Protected poles description":"3t","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2","Ambient air temperature for storage":"-35...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"5 kA at 125 V DC conforming to IEC 60947-2 5 kA at 250 V DC conforming to IEC 60947-2 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 415 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e6be77e5898e2c2e2635e4d106e642e4.pdf","sourceUrl":"https://www.se.com/ph/en/product/EZC100H4075/circuit-breaker-easypact-ezc100h-tmd-75-a-4-poles-3d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/EZC100H4075/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of EZC100H4075 at 400 V?","answer":"The EZC100H4075 delivers 30 kA Icu at 380–400 V AC 50/60 Hz, certified to IEC 60947-2. At 220–240 V AC it reaches 50 kA Icu, and at 110–130 V AC it reaches 100 kA Icu."},{"question":"How do I get pricing and availability for EZC100H4075?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Current pricing and availability are confirmed at quote time — submit an RFQ for a firm commercial offer."},{"question":"What standards does the EZC100H4075 comply with?","answer":"It complies with IEC 60947-2, IEC 60947-1, JIS C8201-2-2, and GB/T 14048.2. It is certified for isolation per IEC 60947-2."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZC100H4075","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZC100H4075 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}