{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZC100N1015","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZC100N1015","canonicalUrl":"https://aoctrl.com/schneider/EZC100N1015","factsUrl":"https://aoctrl.com/api/mcp/products/EZC100N1015","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZC100N, EZC100N1015, 1-pole thermal-magnetic circuit breaker, 15 A rated current, 25 kA breaking capacity at 110-130 V AC, IP20, backplate mount.","salesMarkdown":"The Schneider Electric EZC100N1015 is a 1-pole thermal-magnetic circuit breaker from the EasyPact EZC100N series, rated 15 A at 40 °C (15 A at 50 °C with the TM-D trip unit). It's built for distribution duty in fixed-mount panels — backplate mounted, front-connected, and toggled manually. The 25 mm width per pole keeps the rail density tight; a 13000-cycle mechanical durability means it'll outlast most panel refreshes. The EZC100N1015 carries a 25 kA Icu at 110-130 V AC and 18 kA at 220-240 V AC per IEC 60947-2. That's the N breaking capacity code — enough for most secondary distribution panels behind a larger main breaker. At 400-415 V AC it drops to 2.5 kA, so if your line side is 400 V with high fault current, this needs upstream coordination. The 5 kA at 125 V DC (1-pole) covers DC bus or battery circuits. Fixed backplate mount, 25 mm pitch per pole, front connections top and bottom. IP20 finger-safe terminals, pollution degree 3 rated — fine for a clean panel environment. The toggle actuator gives positive contact indication; the thermal-magnetic trip handles both overload and short-circuit without an external relay.","metaTitle":"Schneider Electric EZC100N1015 EasyPact EZC100N Circuit Brea","metaDescription":"Schneider Electric EZC100N1015 EasyPact EZC100N miniature circuit breaker, 15 A thermal-magnetic, 1-pole, 25 kA breaking capacity at 110-130 V AC. Sourced to order against an RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"60 mm","Width":"25 mm","title":"EZC100N1015","Height":"130 mm","Standards":"EN/IEC 60947-2 JIS C8201-2-2 GB/T 14048.2 EN/IEC 60947-1","description":"circuit breaker Easypact EZC100N - TMD - 15 A - 1 pole 1d","Control type":"Toggle","Network type":"DC AC","Mounting mode":"Fixed","Trip unit name":"TM-D","Protection type":"Short-circuit protection Overload protection","lifecycle_stage":"current","Connection pitch":"25 mm","Local signalling":"Positive contact indication","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60664-1 3 conforming to IEC 947-1","Range of product":"EasyPact","Trip unit rating":"15 A at 50 °C","Breaking capacity":"25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 18 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"Easypact EZC100N","Network frequency":"50/60 Hz","Poles description":"1P","Upside connection":"Front","Device application":"Distribution","[In] rated current":"15 A at 40 °C","Downside connection":"Front","Circuit breaker name":"Easypact EZC100N","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Mechanical durability":"13000 cycles","Breaking capacity code":"N","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Neutral protection setting":"Without protection","Protected poles description":"1t","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"125 V DC conforming to IEC 60947-2 415 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-35...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 9 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 1.25 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 1.25 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a6195588d470c5887ad170123fd20012.pdf","sourceUrl":"https://www.se.com/ae/en/product/EZC100N1015/circuit-breaker-easypact-ezc100n-tmd-15-a-1-pole-1d/"},"ai":{"faq":[{"question":"Where can I buy EZC100N1015 and how do I get a price?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is EZC100N1015's breaking capacity at 240 V?","answer":"18 kA Icu at 220-240 V AC per IEC 60947-2."},{"question":"What compliance documentation does this brand provide for EZC100N1015?","answer":"The breaker is certified to EN/IEC 60947-2, JIS C8201-2-2, and GB/T 14048.2. It carries IP20 and IK07 protection ratings and is suitable for isolation per IEC 60947-2."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZC100N1015","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZC100N1015 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}