{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZC100N1016","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZC100N1016","canonicalUrl":"https://aoctrl.com/schneider/EZC100N1016","factsUrl":"https://aoctrl.com/api/mcp/products/EZC100N1016","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZC100N circuit breaker, EZC100N1016, 16 A thermal-magnetic TM-D trip unit, 1-pole, 25 kA Icu at 110-130 V AC, IP20, current production.","salesMarkdown":"The Schneider Electric EZC100N1016 is a 1-pole EasyPact EZC100N circuit breaker with a thermal-magnetic TM-D trip unit rated 16 A at 50 °C. It provides short-circuit and overload protection for distribution circuits. The breaker is designed for fixed backplate mounting with front connections, and uses a toggle for manual control. Rated operational voltage covers 415 V AC 50/60 Hz and 125 V DC, with an insulation voltage of 690 V AC. Breaking capacity reaches 25 kA Icu at 110-130 V AC, 18 kA at 220-240 V AC, and 5 kA at 125 V DC (1-pole). This makes it suitable for branch-circuit protection in panelboards and distribution boards where moderate fault levels are expected. The breaker carries IP20 protection (finger-safe terminals) and IK07 impact resistance. It is certified for isolation per IEC 60947-2, meaning it can be used as a disconnecting means when locked off. ## Integration notes Width of 25 mm and depth of 60 mm fit standard backplate layouts. The 25 mm connection pitch matches common terminal-block spacing. Front connections simplify wiring in tight enclosures. Positive contact indication provides visual confirmation of the contact position. Mechanical durability of 13,000 cycles is adequate for distribution duty where switching is infrequent.","metaTitle":"Schneider Electric EZC100N1016 EasyPact EZC100N Circuit Brea","metaDescription":"Schneider Electric EZC100N1016 EasyPact EZC100N circuit breaker, 16 A thermal-magnetic, 1-pole, 25 kA breaking capacity at 110-130 V AC. Current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"60 mm","Width":"25 mm","Height":"130 mm","Standards":"EN/IEC 60947-2 EN/IEC 60947-1 GB/T 14048.2 JIS C8201-2-2","Control type":"Toggle","Network type":"AC DC","Mounting mode":"Fixed","Trip unit name":"TM-D","Protection type":"Short-circuit protection Overload protection","lifecycle_stage":"current","Connection pitch":"25 mm","Local signalling":"Positive contact indication","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60947","Range of product":"EasyPact","Trip unit rating":"16 A at 50 °C","Breaking capacity":"25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 18 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"Easypact EZC100N","Network frequency":"50/60 Hz","Poles description":"1P","Upside connection":"Front","Device application":"Distribution","[In] rated current":"16 A at 40 °C","Downside connection":"Front","Circuit breaker name":"Easypact EZC100N","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Mechanical durability":"13000 cycles","Breaking capacity code":"N","IK degree of protection":"IK07 conforming to EN 50102","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Neutral protection setting":"Without protection","Protected poles description":"1t","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"125 V DC conforming to IEC 60947-2 415 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-35...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"2.5 kA at 125 V DC conforming to IEC 60947-2 9 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 1.25 kA at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 1.25 kA at 415 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 110...130 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$39.96","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d8d739e1a3a296566917be39c7513c9b.pdf","sourceUrl":"https://www.se.com/vn/en/product/EZC100N1016/circuit-breaker-easypact-ezc100n-tmd-16a-1-pole-1d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/EZC100N1016/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy EZC100N1016?","answer":"The EZC100N1016 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What are the key ratings for EZC100N1016?","answer":"16 A thermal-magnetic trip unit, 1-pole, breaking capacity 25 kA Icu at 110-130 V AC, rated operational voltage 415 V AC / 125 V DC, insulation voltage 690 V AC."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZC100N1016","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZC100N1016 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}