{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZC100N1025","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZC100N1025","canonicalUrl":"https://aoctrl.com/schneider/EZC100N1025","factsUrl":"https://aoctrl.com/api/mcp/products/EZC100N1025","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZC100N, 1-pole MCCB, 25 A TM-D trip unit, 25 kA Icu at 110-130 V AC, 18 kA at 240 V AC, 2.5 kA at 415 V AC, IEC 60947-2.","salesMarkdown":"The Schneider Electric EasyPact EZC100N1025 is a 1-pole (1P) moulded-case circuit breaker (MCCB) from the EasyPact EZC100N series, fitted with a TM-D thermal-magnetic trip unit rated at 25 A at 50 °C. Breaking capacity (Icu) reaches 25 kA at 110-130 V AC, 18 kA at 220-240 V AC, and 2.5 kA at 400-415 V AC — all per IEC 60947-2. At 125 V DC, 1-pole configuration delivers 5 kA Icu. Rated insulation voltage (Ui) is 690 V AC, and rated operational voltage (Ue) covers 415 V AC and 125 V DC. The breaker is certified for isolation per IEC 60947-2, meaning it provides a visible-break isolation function when open. Pollution degree 3 (IEC 60664-1) suits it for typical panel environments where conductive pollution may occur. Connection pitch is 25 mm, matching the 25 mm width per pole — a standard 1-module footprint for DIN-rail-compatible MCCBs. Depth is 60 mm, height 130 mm. IP20 finger-safe protection on the front face; IK07 impact resistance per IEC 62262. The toggle actuator provides positive contact indication, so the operator can visually confirm the contact position. Designed and tested to JIS C8201-2-2, EN/IEC 60947-2, GB/T 14048.2, and EN/IEC 60947-1. The IEC 60947-2 certification covers low-voltage switchgear and controlgear — specifically circuit-breaker performance, breaking capacity, and isolation function. Mechanical durability is rated at 13,000 cycles. No earth-leakage protection module is integrated; neutral protection is not provided (1P, no neutral pole).","metaTitle":"Schneider EasyPact EZC100N1025 25A 1P MCCB, 25 kA Icu","metaDescription":"Schneider Electric EasyPact EZC100N1025 1-pole MCCB, 25 A rated current, 25 kA Icu at 110-130 V AC. Thermal-magnetic TM-D trip unit. Active production, sourced to order. Quoted on","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"60 mm","Width":"25 mm","title":"EZC100N1025","Height":"130 mm","Standards":"JIS C8201-2-2 EN/IEC 60947-2 GB/T 14048.2 EN/IEC 60947-1","description":"circuit breaker Easypact EZC100N - TMD - 25 A - 1 pole 1d","Control type":"Toggle","Network type":"AC DC","Mounting mode":"Fixed","Trip unit name":"TM-D","Protection type":"Overload protection Short-circuit protection","lifecycle_stage":"current","Connection pitch":"25 mm","Local signalling":"Positive contact indication","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60664-1 3 conforming to IEC 947-1","Range of product":"EasyPact","Trip unit rating":"25 A at 50 °C","Breaking capacity":"25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 18 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"Easypact EZC100N","Network frequency":"50/60 Hz","Poles description":"1P","Upside connection":"Front","Device application":"Distribution","[In] rated current":"25 A at 40 °C","Downside connection":"Front","Circuit breaker name":"Easypact EZC100N","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Mechanical durability":"13000 cycles","Breaking capacity code":"N","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Neutral protection setting":"Without protection","Protected poles description":"1t","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"125 V DC conforming to IEC 60947-2 415 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-35...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 9 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 1.25 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 1.25 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$59.95","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b6f2a3160457fc2a8c4efc7262c00594.pdf","sourceUrl":"https://www.se.com/ae/en/product/EZC100N1025/circuit-breaker-easypact-ezc100n-tmd-25-a-1-pole-1d/"},"ai":{"faq":[{"question":"What are the key ratings of the EZC100N1025?","answer":"Rated current 25 A at 40 °C (25 A at 50 °C on the TM-D trip unit). Breaking capacity 25 kA Icu at 110-130 V AC, 18 kA at 220-240 V AC, 2.5 kA at 400-415 V AC, and 5 kA at 125 V DC. Rated insulation voltage 690 V AC, operational voltage 415 V AC / 125 V DC. 1 pole, thermal-magnetic trip."},{"question":"Where can I buy the EZC100N1025?","answer":"The EZC100N1025 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What compliance documentation does Schneider provide for EZC100N1025?","answer":"The breaker is certified to EN/IEC 60947-2, JIS C8201-2-2, and GB/T 14048.2. It carries an IP20 protection rating and IK07 impact resistance. Specific RoHS/REACH/UL documentation should be requested at quote time as it varies by manufacturing batch."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZC100N1025","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZC100N1025 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}