{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZC100N1025","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZC100N1025","canonicalUrl":"https://aoctrl.com/schneider/EZC100N1025","factsUrl":"https://aoctrl.com/api/mcp/products/EZC100N1025","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZC100N, 1-pole MCCB, 25 A TM-D trip unit, 25 kA Icu at 110-130 V AC, 18 kA at 240 V AC, 2.5 kA at 415 V AC, IEC 60947-2.","salesMarkdown":"The Schneider Electric EasyPact EZC100N1025 is a 1-pole (1P) moulded-case circuit breaker (MCCB) from the EasyPact EZC100N series, fitted with a TM-D thermal-magnetic trip unit rated at 25 A at 50 °C. Breaking capacity (Icu) reaches 25 kA at 110-130 V AC, 18 kA at 220-240 V AC, and 2.5 kA at 400-415 V AC — all per IEC 60947-2. At 125 V DC, 1-pole configuration delivers 5 kA Icu. Rated insulation voltage (Ui) is 690 V AC, and rated operational voltage (Ue) covers 415 V AC and 125 V DC. The breaker is certified for isolation per IEC 60947-2, meaning it provides a visible-break isolation function when open. Pollution degree 3 (IEC 60664-1) suits it for typical panel environments where conductive pollution may occur. Connection pitch is 25 mm, matching the 25 mm width per pole — a standard 1-module footprint for DIN-rail-compatible MCCBs. Depth is 60 mm, height 130 mm. IP20 finger-safe protection on the front face; IK07 impact resistance per IEC 62262. The toggle actuator provides positive contact indication, so the operator can visually confirm the contact position. Designed and tested to JIS C8201-2-2, EN/IEC 60947-2, GB/T 14048.2, and EN/IEC 60947-1. The IEC 60947-2 certification covers low-voltage switchgear and controlgear — specifically circuit-breaker performance, breaking capacity, and isolation function. Mechanical durability is rated at 13,000 cycles. No earth-leakage protection module is integrated; neutral protection is not provided (1P, no neutral pole).","metaTitle":"Schneider EasyPact EZC100N1025 25A 1P MCCB, 25 kA Icu","metaDescription":"Schneider Electric EasyPact EZC100N1025 1-pole MCCB, 25 A rated current, 25 kA Icu at 110-130 V AC. Thermal-magnetic TM-D trip unit. Active production, sourced to order. Quoted on","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"60 mm","Width":"25 mm","Height":"130 mm","Voltage":"125 V DC conforming to IEC 60947-2 415 V AC 50/60 Hz conforming to IEC 60947-2","IP Rating":"IP20","Application":"Distribution","Control Type":"Toggle","Product Status":"Active","Terminal Pitch":"25 mm","Trip Unit Type":"Thermal-magnetic","Pollution Degree":"3 conforming to IEC 60664-1 3 conforming to IEC 947-1","Temp Storage Max":"85 °C","Temp Storage Min":"-35 °C","Insulation Voltage Ui":"690 V AC 50/60 Hz conforming to IEC 60947-2","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-35...85 °C","Connection Surface Top":"Front","Mechanical Life Cycles":"13000 cycles","Connection Surface Bottom":"Front","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$59.95","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b6f2a3160457fc2a8c4efc7262c00594.pdf","sourceUrl":"https://www.se.com/ae/en/product/EZC100N1025/circuit-breaker-easypact-ezc100n-tmd-25-a-1-pole-1d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/EZC100N1025/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZC100N1025","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZC100N1025 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}