{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZC100N1040","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZC100N1040","canonicalUrl":"https://aoctrl.com/schneider/EZC100N1040","factsUrl":"https://aoctrl.com/api/mcp/products/EZC100N1040","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZC100N, EZC100N1040, 1-pole circuit breaker, 40 A rated current, thermal-magnetic TM-D trip unit, breaking capacity 25 kA at 110-130 V AC, fixed mounting, IP20.","salesMarkdown":"The Schneider Electric EZC100N1040 is a 1-pole EasyPact EZC100N circuit breaker rated 40 A at 40 °C, with a thermal-magnetic TM-D trip unit providing short-circuit and overload protection for distribution circuits. It carries a 25 kA Icu breaking capacity at 110-130 V AC (50/60 Hz) per IEC 60947-2, and 18 kA at 220-240 V AC. The 1-pole form factor with a 25 mm width and 60 mm depth fits standard backplate mounting in distribution panels. At 50 °C the rating holds at 40 A per the TM-D trip curve — no derating needed for moderately warm enclosures. The thermal-magnetic trip responds to sustained overloads (thermal bimetal) and instantaneous short-circuits (magnetic coil), covering the two failure modes a distribution circuit sees. The N breaking capacity code indicates this is the standard-interrupting version of the EZC100N frame. The IP20 finger-safe enclosure protects against solid objects over 12 mm but not against moisture; mount inside a sealed cabinet for wet-area use. Fixed mounting on a backplate with front-facing connections — both line and load terminate on the front face. The 25 mm pole pitch matches standard DIN-rail terminal block spacing, so it aligns cleanly in a multi-pole distribution row. The toggle actuator gives positive contact indication: you can see and feel the mechanism position. Mechanical durability of 13,000 cycles suits frequent switching applications like lighting contactor replacement or machine tool disconnects. The IK07 impact rating handles accidental tool drops during panel maintenance.","metaTitle":"Schneider Electric EZC100N1040 EasyPact EZC100N Circuit Brea","metaDescription":"Schneider Electric EZC100N1040 EasyPact EZC100N circuit breaker, 40 A rated current, 1-pole, thermal-magnetic TM-D trip unit. Breaking capacity 25 kA at 110-130 V AC. Sourced to or","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"60 mm","Width":"25 mm","Height":"130 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-2 GB/T 14048.2 JIS C8201-2-2","Control type":"Toggle","Network type":"AC DC","Mounting mode":"Fixed","Trip unit name":"TM-D","Protection type":"Short-circuit protection Overload protection","lifecycle_stage":"current","Connection pitch":"25 mm","Local signalling":"Positive contact indication","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60664-1 3 conforming to IEC 947-1","Range of product":"EasyPact","Trip unit rating":"40 A at 50 °C","Breaking capacity":"25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 18 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"Easypact EZC100N","Network frequency":"50/60 Hz","Poles description":"1P","Upside connection":"Front","Device application":"Distribution","[In] rated current":"40 A at 40 °C","Downside connection":"Front","Circuit breaker name":"Easypact EZC100N","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Mechanical durability":"13000 cycles","Breaking capacity code":"N","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Neutral protection setting":"Without protection","Protected poles description":"1t","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"125 V DC conforming to IEC 60947-2 415 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-35...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 9 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 1.25 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 1.25 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$39.96","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e1913ef5eb7c67f8c60755fcb06e7f2b.pdf","sourceUrl":"https://www.se.com/ph/en/product/EZC100N1040/circuit-breaker-easypact-ezc100n-tmd-40-a-1-pole-1d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/EZC100N1040/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of the EZC100N1040 at different voltages?","answer":"The EZC100N1040 has a breaking capacity of 25 kA Icu at 110-130 V AC, 18 kA at 220-240 V AC, 5 kA at 125 V DC (1P), and 2.5 kA at 380-415 V AC, all per IEC 60947-2."},{"question":"What standards does the EZC100N1040 comply with?","answer":"The EZC100N1040 complies with EN/IEC 60947-1, EN/IEC 60947-2, GB/T 14048.2, and JIS C8201-2-2. It is suitable for isolation per IEC 60947-2."},{"question":"Where can I buy the EZC100N1040 and how is it quoted?","answer":"The EZC100N1040 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at the time of quote."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZC100N1040","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZC100N1040 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}