{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZC100N1060","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZC100N1060","canonicalUrl":"https://aoctrl.com/schneider/EZC100N1060","factsUrl":"https://aoctrl.com/api/mcp/products/EZC100N1060","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZC100N, EZC100N1060, 1-pole circuit breaker, 60 A, TM-D thermal-magnetic trip, 25 kA Icu at 240 V AC, 18 kA at 240 V, 5 kA at 125 V DC.","salesMarkdown":"The Schneider Electric EZC100N1060 is a 1-pole EasyPact EZC100N circuit breaker rated 60 A at 40 °C, with a TM-D thermal-magnetic trip unit. It carries a 25 kA Icu breaking capacity at 110–130 V AC, 18 kA at 220–240 V AC, and 5 kA at 125 V DC — all per IEC 60947-2. The 60 A frame and 25 mm width make it a compact fit for distribution panels where single-pole branch protection is needed. At 240 V AC it clears 18 kA; at 400–415 V AC the Icu drops to 2.5 kA. For a 1-pole device on a 60 A frame, the 25 kA at 110–130 V AC is the headline number — that's the rating that governs selectivity with an upstream 25 kA or higher device. The 5 kA at 125 V DC matters for telecom or solar combiner boxes where a single pole switches DC. The 25 mm width (one modular unit) snaps into a standard DIN-rail enclosure. IK07 impact rating handles accidental tool drops during commissioning. ## Protection and ratings Thermal-magnetic TM-D trip unit provides overload and short-circuit protection. Rated insulation voltage 690 V AC; operational voltage 415 V AC or 125 V DC. Mechanical durability 13,000 cycles — adequate for panel-switch duty, not for frequent motor starting.","metaTitle":"Schneider Electric EZC100N1060 EasyPact EZC100N, 60 A, 1P, 2","metaDescription":"Schneider Electric EZC100N1060 EasyPact EZC100N circuit breaker, 60 A, 1-pole, 25 kA Icu at 240 V AC, thermal-magnetic TM-D trip unit. Sourced to order against an RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"60 mm","Width":"25 mm","Height":"130 mm","Standards":"EN/IEC 60947-1 GB/T 14048.2 JIS C8201-2-2 EN/IEC 60947-2","Control type":"Toggle","Network type":"AC DC","Mounting mode":"Fixed","Trip unit name":"TM-D","Protection type":"Overload protection Short-circuit protection","lifecycle_stage":"current","Connection pitch":"25 mm","Local signalling":"Positive contact indication","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60664-1 3 conforming to IEC 947-1","Range of product":"EasyPact","Trip unit rating":"60 A at 50 °C","Breaking capacity":"25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 18 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"Easypact EZC100N","Network frequency":"50/60 Hz","Poles description":"1P","Upside connection":"Front","Device application":"Distribution","[In] rated current":"60 A at 40 °C","Downside connection":"Front","Circuit breaker name":"Easypact EZC100N","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Mechanical durability":"13000 cycles","Breaking capacity code":"N","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Neutral protection setting":"Without protection","Protected poles description":"1t","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"125 V DC conforming to IEC 60947-2 415 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-35...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 9 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 1.25 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 1.25 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$39.96","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3cd1a2dfd7410d4123b2e3bf514da343.pdf","sourceUrl":"https://www.se.com/vn/en/product/EZC100N1060/circuit-breaker-easypact-ezc100n-tmd-60a-1-pole-1d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/EZC100N1060/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy EZC100N1060 and how do I get a price?","answer":"The EZC100N1060 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What is the closest pin-compatible alternative to EZC100N1060 in this component family?","answer":"Within the EasyPact EZC100N family, the closest alternative by footprint and function would be a different current rating (e.g., EZC100N1030 for 30 A or EZC100N1080 for 80 A) on the same 1-pole, TM-D platform. All share the same 25 mm width, backplate mounting, and front terminals."},{"question":"What compliance documentation does this brand provide for EZC100N1060?","answer":"The EZC100N1060 is certified to EN/IEC 60947-1, EN/IEC 60947-2, GB/T 14048.2, and JIS C8201-2-2. It carries IP20 and IK07 protection ratings, and is rated for isolation per IEC 60947-2. The manufacturer provides a declaration of conformity covering these standards."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZC100N1060","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZC100N1060 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}