{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZC100N3060","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZC100N3060","canonicalUrl":"https://aoctrl.com/schneider/EZC100N3060","factsUrl":"https://aoctrl.com/api/mcp/products/EZC100N3060","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZC100N series, EZC100N3060, 3-pole thermal-magnetic circuit breaker, 60 A rated current, 10 kA breaking capacity at 440 V AC, IP20, backplate mount.","salesMarkdown":"The Schneider Electric EZC100N3060 is a 3-pole thermal-magnetic circuit breaker from the EasyPact EZC100N series, rated 60 A at 40 °C ambient. Breaking capacity hits 10 kA Icu at 440 V AC (50/60 Hz) per IEC 60947-2 — enough for most light industrial distribution panels. It is also rated 15 kA at 400–415 V, 18 kA at 380 V, and 25 kA at 220–240 V, so the same unit covers different line voltages without swapping frame sizes. Fixed backplate mount, not DIN rail. Connection pitch is 25 mm. IP20 finger-safe terminals; IK07 impact rating means it can take a tool drop without cracking the housing. ## Key ratings in context Operational voltage (Ue) goes to 550 V AC and 250 V DC (2-pole series connection). The 60 A trip rating is at 40 °C; at 50 °C the same trip unit holds 60 A (no derate needed up to that point). Mechanical durability is 13,000 cycles — fine for a distribution breaker that operates a few times a year, but not rated for frequent switching duty.","metaTitle":"Schneider EasyPact EZC100N3060 3P 60A Circuit Breaker, 10kA","metaDescription":"EZC100N3060 is a Schneider EasyPact EZC100N 3-pole thermal-magnetic circuit breaker, 60A rated, 10kA breaking capacity at 440V AC. Current lifecycle. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"60 mm","Width":"75 mm","title":"EZC100N3060","Height":"130 mm","Standards":"EN/IEC 60947-1 JIS C8201-2-2 GB/T 14048.2 EN/IEC 60947-2","description":"circuit breaker Easypact EZC100N - TMD - 60 A - 3 poles 3d","Control type":"Toggle","Network type":"AC DC","Mounting mode":"Fixed","Trip unit name":"TM-D","Protection type":"Overload protection Short-circuit protection","lifecycle_stage":"current","Connection pitch":"25 mm","Local signalling":"Positive contact indication","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60664-1 3 conforming to IEC 947-1","Range of product":"EasyPact","Trip unit rating":"60 A at 50 °C","Breaking capacity":"10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"Easypact EZC100N","Network frequency":"50/60 Hz","Poles description":"3P","Upside connection":"Front","Device application":"Distribution","[In] rated current":"60 A at 40 °C","Downside connection":"Front","Circuit breaker name":"Easypact EZC100N","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Mechanical durability":"13000 cycles","Breaking capacity code":"N","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Neutral protection setting":"Without protection","Protected poles description":"3t","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2","Ambient air temperature for storage":"-35...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 9 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$49.96","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/822f65e830027df49d1851625bd99296.pdf","sourceUrl":"https://www.se.com/ae/en/product/EZC100N3060/circuit-breaker-easypact-ezc100n-tmd-60-a-3-poles-3d/"},"ai":{"faq":[{"question":"Where can I buy EZC100N3060 and how is it quoted?","answer":"Sourced and quoted to order through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer."},{"question":"What is the breaking capacity of EZC100N3060 at 440 V?","answer":"10 kA Icu at 440 V AC 50/60 Hz per IEC 60947-2. At 400–415 V it is 15 kA; at 380 V it is 18 kA; at 220–240 V it is 25 kA."},{"question":"Does EZC100N3060 include earth-leakage protection?","answer":"No. The EZC100N3060 is a thermal-magnetic breaker without earth-leakage protection. It provides overload and short-circuit protection only."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZC100N3060","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZC100N3060 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}