{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZC100N3063","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZC100N3063","canonicalUrl":"https://aoctrl.com/schneider/EZC100N3063","factsUrl":"https://aoctrl.com/api/mcp/products/EZC100N3063","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZC100N, EZC100N3063, 3-pole MCCB, 63 A thermal-magnetic trip, 10 kA Icu at 440 V AC, IEC 60947-2.","salesMarkdown":"The Schneider Electric EZC100N3063 is a 3-pole EasyPact EZC100N moulded-case circuit breaker with a 63 A thermal-magnetic trip unit (TM-D) rated at 50 °C. It delivers 10 kA Icu at 440 V AC 50/60 Hz per IEC 60947-2, with higher interrupting ratings at lower voltages — 25 kA at 220–240 V AC and 18 kA at 380–400 V AC. ## Breaking capacity and application context At 415 V AC it holds 15 kA, and at 380–400 V AC it reaches 18 kA, giving headroom for systems with higher available fault current at lower line voltages. The 5 kA Icu at 125 V DC (1-pole) and 250 V DC (2-pole) covers DC distribution sub-circuits, though the primary application is AC distribution per the device application field. The IP20 finger-safe terminals and IK07 impact resistance suit panel-mount installations where incidental contact is possible. Fixed-mount via backplate with front-front connections (both line and load sides). The toggle actuator provides positive contact indication — you can visually confirm the contact position without removing the front cover.","metaTitle":"Schneider Electric EZC100N3063 EasyPact EZC100N, 63 A, 10 kA","metaDescription":"Schneider Electric EZC100N3063 EasyPact EZC100N circuit breaker, 63 A thermal-magnetic, 10 kA Icu at 440 V AC, IEC 60947-2. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"60 mm","Width":"75 mm","title":"EZC100N3063","Height":"130 mm","Standards":"JIS C8201-2-2 EN/IEC 60947-1 EN/IEC 60947-2 GB/T 14048.2","description":"circuit breaker Easypact EZC100N - TMD - 63 A - 3 poles 3d","Control type":"Toggle","Network type":"DC AC","Mounting mode":"Fixed","Trip unit name":"TM-D","Protection type":"Overload protection Short-circuit protection","lifecycle_stage":"current","Connection pitch":"25 mm","Local signalling":"Positive contact indication","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60947","Range of product":"EasyPact","Trip unit rating":"63 A at 50 °C","Breaking capacity":"10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"Easypact EZC100N","Network frequency":"50/60 Hz","Poles description":"3P","Upside connection":"Front","Device application":"Distribution","[In] rated current":"63 A at 40 °C","Downside connection":"Front","Circuit breaker name":"Easypact EZC100N","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Mechanical durability":"13000 cycles","Breaking capacity code":"N","IK degree of protection":"IK07 conforming to EN 50102","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Neutral protection setting":"Without protection","Protected poles description":"3t","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2","Ambient air temperature for storage":"-35...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 9 kA at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 415 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$49.96","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d622735c16dbfe958241b531e734fbb1.pdf","sourceUrl":"https://www.se.com/ph/en/product/EZC100N3063/circuit-breaker-easypact-ezc100n-tmd-63-a-3-poles-3d/"},"ai":{"faq":[{"question":"What are the key ratings of EZC100N3063?","answer":"63 A thermal-magnetic trip at 50 °C, 10 kA Icu at 440 V AC, 18 kA at 380–400 V AC, 25 kA at 220–240 V AC. Rated insulation voltage 690 V AC, operational voltage 550 V AC. Three poles, IEC 60947-2 Category A."},{"question":"What standards does the EZC100N3063 comply with?","answer":"Compliant with IEC 60947-1, IEC 60947-2, JIS C8201-2-2, and GB/T 14048.2. Suitable for isolation per IEC 60947-2."},{"question":"Where can I buy the EZC100N3063?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the depth of the EZC100N3063?","answer":"The depth is 60 mm, with a width of 75 mm and height of 130 mm."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZC100N3063","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZC100N3063 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}