{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZC100N3080","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZC100N3080","canonicalUrl":"https://aoctrl.com/schneider/EZC100N3080","factsUrl":"https://aoctrl.com/api/mcp/products/EZC100N3080","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZC100N, MCCB, 3-pole, 80 A (TM-D), 10 kA Icu at 440 V AC, thermal-magnetic, IEC 60947-2.","salesMarkdown":"The Schneider Electric EZC100N3080 is a 3-pole EasyPact EZC100N moulded-case circuit breaker (MCCB) with a thermal-magnetic TM-D trip unit, rated 80 A at 40 °C ambient and 80 A at 50 °C. The TM-D trip combines a thermal bimetal for overload protection and a magnetic coil for short-circuit protection. Breaking capacity is the key selection parameter for fault duty. This breaker carries an N breaking capacity code with an Icu of 10 kA at 440 V AC. At 400…415 V AC the Icu rises to 15 kA, and at 380 V AC it reaches 18 kA. For DC applications, the Icu is 5 kA at 125 V DC (1-pole) and 5 kA at 250 V DC (2-pole). This MCCB is a Category A device, meaning it is not specifically designed for selectivity under short-circuit conditions with other breakers downstream — coordination studies should account for that. The EZC100N3080 is a fixed-mount MCCB intended for backplate mounting in distribution panels or enclosures. Its dimensions are 130 mm height × 75 mm width × 60 mm depth. The 25 mm connection pitch matches standard busbar or cable-lug spacing. Both line and load connections are front-facing, simplifying wiring access in a panel layout. The IP20 degree of protection means it is finger-safe but not sealed against moisture — install it inside a cabinet rated for the environment.","metaTitle":"Schneider Electric EZC100N3080 EasyPact EZC100N MCCB, 80 A,","metaDescription":"Schneider Electric EZC100N3080 EasyPact EZC100N MCCB, 80 A rated at 40 °C, 10 kA Icu at 440 V AC. TM-D thermal-magnetic trip, 3-pole, IEC 60947-2. Sourced to order against an RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"60 mm","Width":"75 mm","title":"EZC100N3080","Height":"130 mm","Standards":"EN/IEC 60947-2 GB/T 14048.2 JIS C8201-2-2 EN/IEC 60947-1","description":"circuit breaker,EasyPact EZC100N,TMD, 80A,3 poles 3d","Control type":"Toggle","Network type":"AC DC","Mounting mode":"Fixed","Trip unit name":"TM-D","Protection type":"Overload protection Short-circuit protection","lifecycle_stage":"current","Connection pitch":"25 mm","Local signalling":"Positive contact indication","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60664-1 3 conforming to IEC 947-1","Range of product":"EasyPact","Trip unit rating":"80 A at 50 °C","Breaking capacity":"10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"Easypact EZC100N","Network frequency":"50/60 Hz","Poles description":"3P","Upside connection":"Front","Device application":"Distribution","[In] rated current":"80 A at 40 °C","Downside connection":"Front","Circuit breaker name":"Easypact EZC100N","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Mechanical durability":"13000 cycles","Breaking capacity code":"N","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Neutral protection setting":"Without protection","Protected poles description":"3t","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2","Ambient air temperature for storage":"-35...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 9 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$49.96","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/dcb0f6b6bbd611d20577d5c816408f5a.pdf","sourceUrl":"https://www.se.com/vn/en/product/EZC100N3080/circuit-breakereasypact-ezc100n-tmd-80a-3-poles-3d/"},"ai":{"faq":[{"question":"What is the breaking capacity of the EZC100N3080 at 440 V?","answer":"The breaking capacity (Icu) is 10 kA at 440 V AC 50/60 Hz per IEC 60947-2."},{"question":"What compliance documentation is available for the EZC100N3080?","answer":"The breaker is certified to EN/IEC 60947-2, GB/T 14048.2, JIS C8201-2-2, and carries an IK07 impact rating. Documentation includes the IEC standard test reports and the manufacturer's declaration of conformity."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZC100N3080","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZC100N3080 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}