{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZC250F3100","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZC250F3100","canonicalUrl":"https://aoctrl.com/schneider/EZC250F3100","factsUrl":"https://aoctrl.com/api/mcp/products/EZC250F3100","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZC250F, 3-pole circuit breaker, 100 A thermal-magnetic TM-D trip unit, 10 kA Icu at 440 V AC, fixed mount, toggle control.","salesMarkdown":"It carries a 10 kA Icu breaking capacity at 440 V AC (15 kA at 400 V, 25 kA at 240 V) under IEC 60947-2, and is suitable for isolation per that standard. The 690 V rated insulation voltage and Category A utilization class mean it's sized for panelboard feeder or branch protection where fault levels stay within its interrupting envelope. The 100 A trip rating at 40 °C (same at 50 °C) sets the continuous load limit — size the upstream conductor and downstream load for that, not the breaker frame's max. The TM-D thermal-magnetic trip gives short-circuit and overload protection in one unit; the thermal element handles sustained overcurrents, the magnetic element clears fast on high faults. IP20 finger-safe protection on the front; IK07 impact rating means it handles incidental tool contact during wiring.","metaTitle":"Schneider Electric EZC250F3100 EasyPact EZC250F Circuit Brea","metaDescription":"Schneider Electric EZC250F3100 EasyPact EZC250F 3-pole circuit breaker, 100 A thermal-magnetic TM-D trip unit, 10 kA breaking capacity at 440 V AC. IEC 60947-2. Active production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"60 mm","Width":"105 mm","Height":"165 mm","Voltage":"550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2","IP Rating":"IP20","Application":"Distribution","Control Type":"Toggle","Network Type":"DC AC","Product Status":"Active","Terminal Pitch":"35 mm","Trip Unit Type":"Thermal-magnetic","Pollution Degree":"3 conforming to IEC 60664-1 3 conforming to IEC 947-1","Temp Storage Max":"85 °C","Temp Storage Min":"-35 °C","Breaking Capacity":"10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2","Insulation Voltage Ui":"690 V AC 50/60 Hz conforming to IEC 60947-2","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-35...85 °C","Connection Surface Top":"Front","Mechanical Life Cycles":"10000 cycles","Connection Surface Bottom":"Front","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b3f71466c85bfdbd948280a249a63103.pdf","sourceUrl":"https://www.se.com/ae/en/product/EZC250F3100/circuit-breaker-easypact-ezc250f-tmd-100-a-3-poles-3d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/EZC250F3100/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZC250F3100","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZC250F3100 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}