{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZC250H2175","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZC250H2175","canonicalUrl":"https://aoctrl.com/schneider/EZC250H2175","factsUrl":"https://aoctrl.com/api/mcp/products/EZC250H2175","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZC250H series, EZC250H2175, 2-pole MCCB, 175 A rated current, TM-D thermal-magnetic trip unit, 36 kA breaking capacity at 400 V AC.","salesMarkdown":"The Schneider Electric EZC250H2175 is a 2-pole EasyPact EZC250H MCCB rated 175 A at 40 °C, with a TM-D thermal-magnetic trip unit. It's a distribution-grade circuit breaker per IEC 60947-2, Category A, meaning it's not intended for selective coordination in series with other breakers — it clears faults independently. The 36 kA Icu at 400 V AC (50/60 Hz) is the headline breaking capacity for most European and Asian 400 V lineups; at 550 V AC it still holds 10 kA, so it handles the full voltage range of a standard 400 V system with headroom. This H-code frame delivers 85 kA Icu at 220-240 V AC and 36 kA at 400-415 V AC — that's the number that matters for most distribution panels. At 550 V AC it drops to 10 kA, and on DC it offers 30 kA at 125 V DC (1-pole) or 250 V DC (2-pole). For a 175 A frame, 36 kA at 400 V is solid for secondary distribution; if your fault current exceeds that, step up to the S or L breaking capacity codes in the same EasyPact EZC250 family. Fixed backplate mount, front connections top and bottom. Connection pitch is 35 mm between poles — standard for a 2-pole frame this size. IP20 finger-safe front, IK07 impact resistance. ## Protection and control The TM-D trip unit provides short-circuit and overload protection — no earth-leakage module on this variant. Positive contact indication on the toggle gives visual confirmation of contact position. Ambient operating range -25 to 70 °C; the 175 A rating at 40 °C derates at higher temperatures — at 50 °C the trip unit rating is still 175 A, but the continuous current capacity follows the thermal curve.","metaTitle":"Schneider Electric EZC250H2175 EasyPact EZC250H 175A 2P MCCB","metaDescription":"Schneider Electric EZC250H2175 EasyPact EZC250H 2-pole MCCB, 175A rated current, TM-D trip unit, 36kA at 400V AC. IEC 60947-2. Current lifecycle stage. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"60 mm","Width":"105 mm","title":"EZC250H2175","Height":"165 mm","Standards":"GB/T 14048.2 EN/IEC 60947-2 EN/IEC 60947-1","description":"circuit breaker Easypact EZC250H - TMD - 175 A - 2 poles 2d","Control type":"Toggle","Network type":"AC DC","Mounting mode":"Fixed","Trip unit name":"TM-D","Protection type":"Short-circuit protection Overload protection","lifecycle_stage":"current","Connection pitch":"35 mm","Local signalling":"Positive contact indication","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60664-1 3 conforming to IEC 947-1","Range of product":"EasyPact","Trip unit rating":"175 A at 50 °C","Breaking capacity":"10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 125 V DC 1P conforming to IEC 60947-2 30 kA Icu at 250 V DC 2P conforming to IEC 60947-2 36 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"Easypact EZC250H","Network frequency":"50/60 Hz","Poles description":"2P","Upside connection":"Front","Device application":"Distribution","[In] rated current":"175 A at 40 °C","Downside connection":"Front","Circuit breaker name":"Easypact EZC250H","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Mechanical durability":"10000 cycles","Breaking capacity code":"H","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Neutral protection setting":"Without protection","Protected poles description":"2t","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2","Ambient air temperature for storage":"-35...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 125 V DC conforming to IEC 60947-2 15 kA at 250 V DC conforming to IEC 60947-2 18 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b1b60a3e86b91061b3b4a5bfc3768bef.pdf","sourceUrl":"https://www.se.com/ph/en/product/EZC250H2175/circuit-breaker-easypact-ezc250h-tmd-175-a-2-poles-2d/"},"ai":{"faq":[{"question":"Where can I buy the EZC250H2175 and get a price?","answer":"This part is sourced to order against an RFQ through independent distribution channels. Submit a quote request for current availability and pricing — confirmed at time of quotation."},{"question":"What is the breaking capacity of the EZC250H2175 at 400 V?","answer":"36 kA Icu at 400-415 V AC 50/60 Hz per IEC 60947-2. At 220-240 V AC it's 85 kA; at 550 V AC it's 10 kA."},{"question":"What compliance standards does the EZC250H2175 meet?","answer":"It complies with IEC 60947-2 and IEC 60947-1, plus the Chinese standard GB/T 14048.2. It is not UL-listed — this is an IEC-rated device for global markets outside North America."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZC250H2175","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZC250H2175 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}