{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZC250H2250","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZC250H2250","canonicalUrl":"https://aoctrl.com/schneider/EZC250H2250","factsUrl":"https://aoctrl.com/api/mcp/products/EZC250H2250","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZC250H, 2-pole MCCB, 250 A rated, thermal-magnetic TM-D trip unit, 36 kA Icu at 415 V AC, fixed mount.","salesMarkdown":"The Schneider Electric EZC250H2250 is a 2-pole EasyPact EZC250H molded-case circuit breaker (MCCB) with a TM-D thermal-magnetic trip unit rated 250 A at 40 °C. At 550 V AC it still interrupts 10 kA, so it can sit on a 480 V line in North America or a 500 V industrial bus in Europe without coordination problems. The Icu varies with applied voltage — 85 kA at 240 V AC, 36 kA at 415 V AC, 25 kA at 440 V AC, 10 kA at 550 V AC. That's typical for a compact MCCB: the arc-quenching chamber has a fixed energy limit, so the same hardware clears more current at lower voltage. For a 480/277 V wye service the 36 kA at 400–415 V AC is the relevant figure; derate to the 25 kA at 440 V AC if the system runs at 480 V phase-to-phase. The DC ratings — 30 kA Icu at 125 V DC 1P and 250 V DC 2P — let it serve as a battery or UPS disconnect where DC fault currents are high. Fixed backplate mount — no DIN-rail adapter, so it bolts directly to a panel backplate. The 105 mm width × 165 mm height × 60 mm depth fits a standard MCCB cutout; the 35 mm connection pitch aligns with busbar or cable-lug spacing on a distribution block. Ambient operating range of –25 to 70 °C covers most electrical rooms; storage range of –35 to 85 °C handles warehouse extremes. Designed and tested to GB/T 14048.2, EN/IEC 60947-1, and EN/IEC 60947-2 — the global standard for low-voltage switchgear and controlgear. Suitability for isolation per IEC 60947-2 confirms that with the toggle in the OFF position, the breaker provides a visible break — important for lockout/tagout procedures. Mechanical durability of 10,000 cycles is standard for a distribution MCCB; expect electrical life to be lower under full rated load.","metaTitle":"Schneider Electric EZC250H2250 EasyPact EZC250H, 250A, 2P MC","metaDescription":"Schneider Electric EZC250H2250 EasyPact EZC250H circuit breaker. 250A rated, 2-pole, 36kA at 415V AC. Thermal-magnetic TM-D trip unit. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"60 mm","Width":"105 mm","title":"EZC250H2250","Height":"165 mm","Standards":"GB/T 14048.2 EN/IEC 60947-1 EN/IEC 60947-2","description":"circuit breaker Easypact EZC250H - TMD - 250 A - 2 poles 2d","Control type":"Toggle","Network type":"DC AC","Mounting mode":"Fixed","Trip unit name":"TM-D","Protection type":"Short-circuit protection Overload protection","lifecycle_stage":"current","Connection pitch":"35 mm","Local signalling":"Positive contact indication","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60664-1 3 conforming to IEC 947-1","Range of product":"EasyPact","Trip unit rating":"250 A at 50 °C","Breaking capacity":"10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 125 V DC 1P conforming to IEC 60947-2 30 kA Icu at 250 V DC 2P conforming to IEC 60947-2 36 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"Easypact EZC250H","Network frequency":"50/60 Hz","Poles description":"2P","Upside connection":"Front","Device application":"Distribution","[In] rated current":"250 A at 40 °C","Downside connection":"Front","Circuit breaker name":"Easypact EZC250H","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Mechanical durability":"10000 cycles","Breaking capacity code":"H","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Neutral protection setting":"Without protection","Protected poles description":"2t","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2","Ambient air temperature for storage":"-35...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 125 V DC conforming to IEC 60947-2 15 kA at 250 V DC conforming to IEC 60947-2 18 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9294a438c52ee7de51655951b98a004a.pdf","sourceUrl":"https://www.se.com/ae/en/product/EZC250H2250/circuit-breaker-easypact-ezc250h-tmd-250-a-2-poles-2d/"},"ai":{"faq":[{"question":"Who supplies EZC250H2250 and how is it quoted for volume purchases?","answer":"EZC250H2250 is sourced through independent industrial-automation distribution and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time for any volume — single units or production lots."},{"question":"What is the breaking capacity of EZC250H2250 at 415 V AC?","answer":"At 400–415 V AC 50/60 Hz, the EZC250H2250 delivers 36 kA Icu per IEC 60947-2. That's the figure to use for most 400 V class distribution panels."},{"question":"What compliance documentation does this brand provide for EZC250H2250?","answer":"The EZC250H2250 is designed to GB/T 14048.2, EN/IEC 60947-1, and EN/IEC 60947-2 standards. It carries IP20 finger protection and IK07 impact resistance. RoHS and REACH declarations are standard for Schneider EasyPact products."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZC250H2250","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZC250H2250 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}