{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZC250H3160","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZC250H3160","canonicalUrl":"https://aoctrl.com/schneider/EZC250H3160","factsUrl":"https://aoctrl.com/api/mcp/products/EZC250H3160","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZC250H, 3-pole molded case circuit breaker, 160 A, TM-D thermal-magnetic trip unit, 36 kA breaking capacity at 400 V AC.","salesMarkdown":"The Schneider Electric EZC250H3160 is a 3-pole molded case circuit breaker from the EasyPact EZC250H series, rated 160 A at 40 °C with a TM-D thermal-magnetic trip unit. It provides short-circuit and overload protection for distribution applications, with a breaking capacity of 36 kA Icu at 400...415 V AC 50/60 Hz per IEC 60947-2. The H breaking capacity code means it handles higher fault currents than the standard S or N variants in the same frame, making it suitable for main or sub-feed protection where available fault current exceeds 25 kA. The 160 A trip unit rating at 50 °C and 160 A rated current at 40 °C define the continuous load it can carry without nuisance tripping. Breaking capacity varies by voltage: 85 kA Icu at 240 V AC, 36 kA at 400 V, 25 kA at 440 V, and 10 kA at 550 V AC. On DC systems, it delivers 30 kA Icu at 125 V DC (1-pole) or 250 V DC (2-pole). The IP20 finger-safe enclosure and IK07 impact resistance protect against accidental contact and light mechanical shock during panel maintenance. Fixed backplate mounting with front-connect terminals — both line and load connections are on the front face, so the breaker can be installed in a panel without rear-access buswork. Toggle control with positive contact indication gives a clear visual of contact state, useful during lockout/tagout.","metaTitle":"Schneider Electric EZC250H3160 EasyPact EZC250H 160A 3P MCCB","metaDescription":"Schneider Electric EZC250H3160 EasyPact EZC250H 3-pole MCCB, 160A rated current, 36kA breaking capacity at 400V AC. TM-D thermal-magnetic trip unit. Current lifecycle. Sourced to o","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"60 mm","Width":"105 mm","title":"EZC250H3160","Height":"165 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-2 GB/T 14048.2","description":"circuit breaker Easypact EZC250H - TMD - 160 A - 3 poles 3d","Control type":"Toggle","Network type":"AC DC","Mounting mode":"Fixed","Trip unit name":"TM-D","Protection type":"Short-circuit protection Overload protection","lifecycle_stage":"current","Connection pitch":"35 mm","Local signalling":"Positive contact indication","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60664-1 3 conforming to IEC 947-1","Range of product":"EasyPact","Trip unit rating":"160 A at 50 °C","Breaking capacity":"10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 125 V DC 1P conforming to IEC 60947-2 30 kA Icu at 250 V DC 2P conforming to IEC 60947-2 36 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"Easypact EZC250H","Network frequency":"50/60 Hz","Poles description":"3P","Upside connection":"Front","Device application":"Distribution","[In] rated current":"160 A at 40 °C","Downside connection":"Front","Circuit breaker name":"Easypact EZC250H","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Mechanical durability":"10000 cycles","Breaking capacity code":"H","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Neutral protection setting":"Without protection","Protected poles description":"3t","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2","Ambient air temperature for storage":"-35...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 125 V DC conforming to IEC 60947-2 15 kA at 250 V DC conforming to IEC 60947-2 18 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/23318d34ce234c4d557de0674a6ea5f0.pdf","sourceUrl":"https://www.se.com/ae/en/product/EZC250H3160/circuit-breaker-easypact-ezc250h-tmd-160-a-3-poles-3d/"},"ai":{"faq":[{"question":"How do I get current pricing and availability for EZC250H3160?","answer":"Pricing and availability are confirmed at quote time. Submit an RFQ through this listing; the response will include current stock position and a firm price for your quantity."},{"question":"What is EZC250H3160's breaking capacity at 400 V?","answer":"The breaking capacity is 36 kA Icu at 400...415 V AC 50/60 Hz per IEC 60947-2. This is the H (high) breaking capacity variant of the EZC250 frame."},{"question":"What compliance standards does EZC250H3160 meet?","answer":"It complies with EN/IEC 60947-1, EN/IEC 60947-2, and GB/T 14048.2. It is suitable for isolation per IEC 60947-2 and rated for pollution degree 3 per IEC 60664-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZC250H3160","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZC250H3160 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}