{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZC250H4160","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZC250H4160","canonicalUrl":"https://aoctrl.com/schneider/EZC250H4160","factsUrl":"https://aoctrl.com/api/mcp/products/EZC250H4160","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZC250H, 4P circuit breaker, 160 A thermal-magnetic TM-D trip unit, 85 kA Icu at 240 V AC, 10 kA Icu at 550 V AC, IEC 60947-2.","salesMarkdown":"The Schneider Electric EZC250H4160 is a 4-pole EasyPact EZC250H moulded-case circuit breaker rated 160 A at 40 °C, with a thermal-magnetic TM-D trip unit. It delivers 85 kA Icu at 220–240 V AC and 10 kA Icu at 550 V AC, meeting the IEC 60947-2 standard for distribution and isolation duty. At 380–415 V AC the rating drops to 36 kA Icu, still adequate for most panelboard main breakers. The 10 kA Icu at 550 V AC is the limiting case for 480 V systems; verify coordination with the upstream device. Fixed backplate mounting, front connections both top and bottom. The 35 mm connection pitch matches standard busbar systems. Depth of 60 mm and width of 140 mm fit a typical distribution panel footprint; leave clearance for the toggle handle and positive-contact indication flag.","metaTitle":"Schneider Electric EZC250H4160 Easypact EZC250H 4P 160A Circ","metaDescription":"Schneider Electric EZC250H4160 Easypact EZC250H 4P circuit breaker, 160A thermal-magnetic TM-D trip, 85kA at 240V AC, 10kA at 550V AC. Active production, sourced to order. Quoted o","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"60 mm","Width":"140 mm","title":"EZC250H4160","Height":"165 mm","Standards":"EN/IEC 60947-2 JIS C8201-2-2 EN/IEC 60947-1 GB/T 14048.2","description":"circuit breaker, EasyPact EZC250H, TMD, 160A, 4 poles 3d","Control type":"Toggle","Network type":"DC AC","Mounting mode":"Fixed","Trip unit name":"TM-D","Protection type":"Short-circuit protection Overload protection","lifecycle_stage":"current","Connection pitch":"35 mm","Local signalling":"Positive contact indication","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60947","Range of product":"EasyPact","Trip unit rating":"160 A at 50 °C","Breaking capacity":"10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 125 V DC 1P conforming to IEC 60947-2 30 kA Icu at 250 V DC 2P conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"Easypact EZC250H","Network frequency":"50/60 Hz","Poles description":"4P","Upside connection":"Front","Device application":"Distribution","[In] rated current":"160 A at 40 °C","Downside connection":"Front","Circuit breaker name":"Easypact EZC250H","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Mechanical durability":"10000 cycles","Breaking capacity code":"H","IK degree of protection":"IK07 conforming to EN 50102","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Neutral protection setting":"Without protection","Protected poles description":"3t","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2","Ambient air temperature for storage":"-35...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 125 V DC conforming to IEC 60947-2 15 kA at 250 V DC conforming to IEC 60947-2 12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6a9a892ebf149f1a2fb0585a84bad1d6.pdf","sourceUrl":"https://www.se.com/vn/en/product/EZC250H4160/circuit-breaker-easypact-ezc250h-tmd-160a-4-poles-3d/"},"ai":{"faq":[{"question":"Where can I buy EZC250H4160 and how do I get a price?","answer":"The EZC250H4160 is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time."},{"question":"What is EZC250H4160's listed depth (60 mm) on this component line?","answer":"The EZC250H4160 has a depth of 60 mm."},{"question":"What is EZC250H4160's listed width (140 mm) on this component line?","answer":"The EZC250H4160 has a width of 140 mm."},{"question":"What compliance documentation does this brand provide for EZC250H4160 (RoHS, REACH, UL, IEC)?","answer":"The EZC250H4160 is certified to IEC 60947-2, JIS C8201-2-2, and GB/T 14048.2. It is suitable for isolation per IEC 60947-2."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZC250H4160","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZC250H4160 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}