{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZC250H4200","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZC250H4200","canonicalUrl":"https://aoctrl.com/schneider/EZC250H4200","factsUrl":"https://aoctrl.com/api/mcp/products/EZC250H4200","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZC250H, molded case circuit breaker, 200 A, 4P, thermal-magnetic TM-D trip unit, 85 kA Icu at 240 V AC, IP20, backplate mount.","salesMarkdown":"The Schneider Electric EZC250H4200 is a 4-pole EasyPact EZC250H molded case circuit breaker with a thermal-magnetic TM-D trip unit, rated 200 A at 40 °C. It carries an 85 kA Icu breaking capacity at 220–240 V AC, dropping to 36 kA at 380–415 V and 10 kA at 550 V — the H code tells you it's the high-breaking version for distribution panels where fault currents are known to be stiff. The 200 A frame means it's sized for a main feeder or a large motor branch circuit, not a lighting panel subfeed. At 480 V class (380–415 V) it still holds 36 kA, which covers most industrial service-entrance requirements. The thermal-magnetic TM-D trip unit gives fixed thermal and magnetic settings — no interchangeable trip plugs, so the 200 A rating is what you get. Category A utilization means it's not intended for motor starting duty under IEC 60947-2; it's a distribution breaker, not a motor circuit protector. Fixed backplate mount — no DIN rail adapter on this frame. Connection pitch is 35 mm, which matches standard busbar spacing for a 200 A breaker. IP20 finger protection on the front, IK07 impact resistance — it's a panel interior device, not a washdown enclosure. The toggle handle gives positive contact indication (ON/OFF/TRIPPED) visible through the front cover.","metaTitle":"Schneider Electric EZC250H4200 EasyPact EZC250H, 200 A, 4P,","metaDescription":"Schneider Electric EZC250H4200 EasyPact EZC250H circuit breaker, 200 A rated current, 4 poles, 85 kA breaking capacity at 240 V. IEC 60947-2. Current lifecycle. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"60 mm","Width":"140 mm","title":"EZC250H4200","Height":"165 mm","Standards":"EN/IEC 60947-1 GB/T 14048.2 EN/IEC 60947-2 JIS C8201-2-2","description":"circuit breaker Easypact EZC250H - TMD - 200 A - 4 poles 3d","Control type":"Toggle","Network type":"AC DC","Mounting mode":"Fixed","Trip unit name":"TM-D","Protection type":"Short-circuit protection Overload protection","lifecycle_stage":"current","Connection pitch":"35 mm","Local signalling":"Positive contact indication","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60947","Range of product":"EasyPact","Trip unit rating":"200 A at 50 °C","Breaking capacity":"10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 125 V DC 1P conforming to IEC 60947-2 30 kA Icu at 250 V DC 2P conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"Easypact EZC250H","Network frequency":"50/60 Hz","Poles description":"4P","Upside connection":"Front","Device application":"Distribution","[In] rated current":"200 A at 40 °C","Downside connection":"Front","Circuit breaker name":"Easypact EZC250H","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Mechanical durability":"10000 cycles","Breaking capacity code":"H","IK degree of protection":"IK07 conforming to EN 50102","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Neutral protection setting":"Without protection","Protected poles description":"3t","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2","Ambient air temperature for storage":"-35...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 125 V DC conforming to IEC 60947-2 15 kA at 250 V DC conforming to IEC 60947-2 12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/dd9ff163566d929fbbdd4b852c96a709.pdf","sourceUrl":"https://www.se.com/ae/en/product/EZC250H4200/circuit-breaker-easypact-ezc250h-tmd-200-a-4-poles-3d/"},"ai":{"faq":[{"question":"How do I get pricing and availability for EZC250H4200?","answer":"Submit an RFQ through this listing. The part is sourced to order through independent distribution; current pricing and stock levels are confirmed at quote time."},{"question":"What compliance standards does EZC250H4200 meet?","answer":"It complies with EN/IEC 60947-1, EN/IEC 60947-2, GB/T 14048.2, and JIS C8201-2-2. It is suitable for isolation per IEC 60947-2."},{"question":"What is the breaking capacity of EZC250H4200 at 240 V?","answer":"85 kA Icu at 220–240 V AC 50/60 Hz per IEC 60947-2. At 380–415 V it's 36 kA; at 550 V it's 10 kA."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZC250H4200","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZC250H4200 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}