{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZC250N3160","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZC250N3160","canonicalUrl":"https://aoctrl.com/schneider/EZC250N3160","factsUrl":"https://aoctrl.com/api/mcp/products/EZC250N3160","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZC250N, EZC250N3160, 3-pole circuit breaker, 160 A rated, 20 kA Icu at 440 V AC, thermal-magnetic TM-D trip unit, fixed mount, IP20.","salesMarkdown":"The Schneider Electric EZC250N3160 is an EasyPact EZC250N 3-pole circuit breaker with a thermal-magnetic TM-D trip unit, rated 160 A at 40 °C and 160 A at 50 °C. For lower voltages the interrupting rating climbs: 50 kA at 220–240 V AC and 25 kA at 380–415 V AC, which gives you headroom on common industrial distribution voltages. Fixed backplate mount with front-facing connections on both line and load sides — the 35 mm connection pitch matches standard busbar systems and DIN-rail terminal blocks. At 105 mm wide, 165 mm tall, and 60 mm deep, it fits a standard distribution enclosure without crowding adjacent breakers. IP20 finger-safe protection on the front face; the IK07 impact rating means it withstands accidental tool strikes during panel work. Certified to GB/T 14048.2, EN/IEC 60947-1, and EN/IEC 60947-2 — the core standards for low-voltage switchgear and controlgear. Category A utilisation means it is not intended for frequent motor switching — it is a distribution breaker, not a motor-starter combination.","metaTitle":"Schneider Electric EZC250N3160 EasyPact EZC250N Circuit Brea","metaDescription":"Schneider Electric EZC250N3160 EasyPact EZC250N circuit breaker, 160 A rated current, 20 kA breaking capacity at 440 V AC, 3-pole, thermal-magnetic TM-D trip unit. Active productio","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"60 mm","Width":"105 mm","title":"EZC250N3160","Height":"165 mm","Standards":"GB/T 14048.2 EN/IEC 60947-1 EN/IEC 60947-2","description":"circuit breaker,EasyPact EZC250N,TMD, 160A,3 poles 3d","Control type":"Toggle","Network type":"DC AC","Mounting mode":"Fixed","Trip unit name":"TM-D","Protection type":"Overload protection Short-circuit protection","lifecycle_stage":"current","Connection pitch":"35 mm","Local signalling":"Positive contact indication","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60664-1 3 conforming to IEC 947-1","Range of product":"EasyPact","Trip unit rating":"160 A at 50 °C","Breaking capacity":"20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 125 V DC 1P conforming to IEC 60947-2 20 kA Icu at 250 V DC 2P conforming to IEC 60947-2 25 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"Easypact EZC250N","Network frequency":"50/60 Hz","Poles description":"3P","Upside connection":"Front","Device application":"Distribution","[In] rated current":"160 A at 40 °C","Downside connection":"Front","Circuit breaker name":"Easypact EZC250N","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Mechanical durability":"10000 cycles","Breaking capacity code":"N","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Neutral protection setting":"Without protection","Protected poles description":"3t","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2","Ambient air temperature for storage":"-35...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 125 V DC conforming to IEC 60947-2 10 kA at 250 V DC conforming to IEC 60947-2 25 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 4 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$134.18","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/94928731e2da2da8b3f18a7343a3c31c.pdf","sourceUrl":"https://www.se.com/vn/en/product/EZC250N3160/circuit-breakereasypact-ezc250n-tmd-160a-3-poles-3d/"},"ai":{"faq":[{"question":"What is the breaking capacity of the EZC250N3160 at 440 V AC?","answer":"20 kA Icu at 440 V AC 50/60 Hz per IEC 60947-2. At 380–415 V AC it rises to 25 kA, and at 220–240 V AC it reaches 50 kA."},{"question":"Where can I buy the EZC250N3160?","answer":"Sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time."},{"question":"What compliance standards does the EZC250N3160 meet?","answer":"Certified to GB/T 14048.2, EN/IEC 60947-1, and EN/IEC 60947-2. Rated for pollution degree 3 and isolation suitability per IEC 60947-2."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZC250N3160","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZC250N3160 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}