{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZC250N3225","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZC250N3225","canonicalUrl":"https://aoctrl.com/schneider/EZC250N3225","factsUrl":"https://aoctrl.com/api/mcp/products/EZC250N3225","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZC250N series, EZC250N3225, 3-pole thermal-magnetic circuit breaker, 225 A rated current, 20 kA Icu at 440 V AC, TM-D trip unit, IP20.","salesMarkdown":"The Schneider Electric EZC250N3225 is a 3-pole thermal-magnetic circuit breaker from the EasyPact EZC250N series, rated 225 A at 40 °C and carrying a TM-D trip unit. The 690 V AC rated insulation voltage (Ui) and 550 V AC maximum operational voltage (Ue) cover most 400/480 V distribution panels. The 225 A rating at 40 °C is the continuous current the breaker carries without tripping in a 40 °C ambient; at 50 °C the same trip unit is rated 225 A, so no derating is required up to that point. For a distribution panel feeding a 225 A bus, this breaker is the main or a large feeder; the 20 kA Icu at 440 V AC is the maximum fault current it can clear once, and the 25 kA Icu at 400 V AC gives a bit more headroom at common European voltages. The 8 kA Icu at 550 V AC is the limit if the system runs at that voltage — rare in distribution, but the rating is there. ## Deployment context The breaker mounts fixed to a backplate with front connections — typical for panel-mounted distribution in switchboards or enclosure backplates. IP20 means finger-safe but not sealed — install inside a cabinet rated for the environment. The toggle control provides positive contact indication for visual confirmation of open/closed state.","metaTitle":"Schneider Electric EZC250N3225 EasyPact EZC250N, 225A, 20kA","metaDescription":"Schneider Electric EZC250N3225 EasyPact EZC250N circuit breaker, 225 A, 20 kA Icu at 440 V AC, thermal-magnetic TM-D trip unit, 3-pole, IP20. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"60 mm","Width":"105 mm","title":"EZC250N3225","Height":"165 mm","Standards":"EN/IEC 60947-2 GB/T 14048.2 EN/IEC 60947-1","description":"circuit breaker Easypact EZC250N - TMD - 225 A - 3 poles 3d","Control type":"Toggle","Network type":"DC AC","Mounting mode":"Fixed","Trip unit name":"TM-D","Protection type":"Short-circuit protection Overload protection","lifecycle_stage":"current","Connection pitch":"35 mm","Local signalling":"Positive contact indication","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60664-1 3 conforming to IEC 947-1","Range of product":"EasyPact","Trip unit rating":"225 A at 50 °C","Breaking capacity":"20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 125 V DC 1P conforming to IEC 60947-2 20 kA Icu at 250 V DC 2P conforming to IEC 60947-2 25 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"Easypact EZC250N","Network frequency":"50/60 Hz","Poles description":"3P","Upside connection":"Front","Device application":"Distribution","[In] rated current":"225 A at 40 °C","Downside connection":"Front","Circuit breaker name":"Easypact EZC250N","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Mechanical durability":"10000 cycles","Breaking capacity code":"N","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Neutral protection setting":"Without protection","Protected poles description":"3t","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2","Ambient air temperature for storage":"-35...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 125 V DC conforming to IEC 60947-2 10 kA at 250 V DC conforming to IEC 60947-2 25 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 4 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e43165aa8f197906fb4f8362b57c395b.pdf","sourceUrl":"https://www.se.com/ph/en/product/EZC250N3225/circuit-breaker-easypact-ezc250n-tmd-225-a-3-poles-3d/"},"ai":{"faq":[{"question":"How do I get current pricing and availability for EZC250N3225?","answer":"Submit an RFQ through this listing. The part is sourced to order through independent distribution; availability and current pricing are confirmed at quote time."},{"question":"What is the closest alternative to EZC250N3225 in the EasyPact family?","answer":"Within the EasyPact EZC250N series, the closest alternative would be a unit with the same frame size and trip rating but a different breaking capacity code (e.g., H for high or S for standard). The EZC250N3225 uses the N (normal) breaking capacity — 20 kA at 440 V AC. A higher-breaking-capacity variant (H code) would be needed if the available fault current exceeds 20 kA at that voltage. No pin-compatible drop-in exists with a different trip unit technology; the TM-D is fixed thermal-magnetic."},{"question":"What compliance documentation does Schneider provide for EZC250N3225?","answer":"The breaker is certified to EN/IEC 60947-2 and GB/T 14048.2, with suitability for isolation per IEC 60947-2. IP20 per IEC 60529 and IK07 per IEC 62262. Pollution degree 3 per IEC 60664-1. Standard documentation includes the declaration of conformity and the IEC test certificate; RoHS and REACH declarations are available from Schneider's documentation portal."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZC250N3225","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZC250N3225 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}