{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZC250N44100","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZC250N44100","canonicalUrl":"https://aoctrl.com/schneider/EZC250N44100","factsUrl":"https://aoctrl.com/api/mcp/products/EZC250N44100","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZC250N, 4-pole circuit breaker, TM-D thermal-magnetic trip unit, 100 A at 40 °C, 20 kA Icu at 440 V AC, toggle control, front connection, fixed backplate mount.","salesMarkdown":"The EZC250N44100 is a 4-pole EasyPact EZC250N moulded-case circuit breaker from Schneider Electric, fitted with a TM-D thermal-magnetic trip unit rated 100 A at 40 °C (100 A at 50 °C). It is a distribution-class breaker (Category A per IEC 60947-2) with a fixed backplate mount and front-facing connections — designed for panel builders who need a compact, no-frills main or feeder breaker in a 4P footprint. Rated operational voltage goes to 550 V AC 50/60 Hz and 250 V DC; insulation voltage is 690 V AC. The breaking capacity code N delivers 20 kA Icu at 440 V AC, 25 kA at 380–415 V AC, and 50 kA at 220–240 V AC — enough for most commercial and light industrial distribution boards. At 125 V DC single-pole it still holds 20 kA Icu. That keeps the BOM simple but means the 100 A rating is the only setting; if the load draw changes, the breaker itself must be swapped. Mounts fixed to a backplate via the four screw holes — no DIN-rail clip, so plan for a dedicated mounting footprint. Dimensions are 165 mm high, 140 mm wide, 60 mm deep, with a 35 mm connection pitch on the front terminals. IP20 finger-safe protection on the front, IK07 impact resistance. The toggle handle gives positive contact indication (ON/OFF/TRIPPED) visible through the enclosure window. Designed and tested to EN/IEC 60947-1 and -2, JIS C8201-2-2, and GB/T 14048.2. Mechanical durability is 10,000 cycles.","metaTitle":"EZC250N44100 EasyPact EZC250N Circuit Breaker, 100 A, 4P, TM","metaDescription":"EZC250N44100 EasyPact EZC250N 4-pole circuit breaker, 100 A thermal-magnetic TM-D trip unit, 20 kA Icu at 440 V AC. Sourced to order against RFQ. IEC 60947-2.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"60 mm","Width":"140 mm","Height":"165 mm","Standards":"EN/IEC 60947-1 JIS C8201-2-2 GB/T 14048.2 EN/IEC 60947-2","Control type":"Toggle","Network type":"DC AC","Mounting mode":"Fixed","Trip unit name":"TM-D","Protection type":"Overload protection Short-circuit protection","lifecycle_stage":"current","Connection pitch":"35 mm","Local signalling":"Positive contact indication","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60947","Range of product":"EasyPact","Trip unit rating":"100 A at 50 °C","Breaking capacity":"20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 125 V DC 1P conforming to IEC 60947-2 20 kA Icu at 250 V DC 2P conforming to IEC 60947-2 8 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"Easypact EZC250N","Network frequency":"50/60 Hz","Poles description":"4P","Upside connection":"Front","Device application":"Distribution","[In] rated current":"100 A at 40 °C","Downside connection":"Front","Circuit breaker name":"Easypact EZC250N","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Mechanical durability":"10000 cycles","Breaking capacity code":"N","IK degree of protection":"IK07 conforming to EN 50102","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Neutral protection setting":"Without protection","Protected poles description":"4t","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2","Ambient air temperature for storage":"-35...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 125 V DC conforming to IEC 60947-2 10 kA at 250 V DC conforming to IEC 60947-2 4 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ab113f446a69d0f9bb67078d1c2f10b0.pdf","sourceUrl":"https://www.se.com/vn/en/product/EZC250N44100/circuit-breaker-easypact-ezc250n-tmd-100-a-4-poles-4d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/EZC250N44100/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy EZC250N44100 and how do I get a price?","answer":"The EZC250N44100 is sourced to order against an RFQ through independent distribution. Submit a request for quote to confirm availability and current pricing."},{"question":"What is the closest pin-compatible alternative to EZC250N44100 in this component family?","answer":"Within the EasyPact EZC250N family, the closest alternative is the same frame with a different trip rating or with an electronic trip unit (EZC250H or EZC250F series). Pin-compatibility depends on the mounting footprint and connection pitch — the 35 mm pitch and backplate mount are shared across the EZC250N range, so swapping to a different current rating within the same frame is a direct mechanical fit."},{"question":"What compliance documentation does this brand provide for EZC250N44100 (RoHS, REACH, UL, IEC)?","answer":"The EZC250N44100 is certified to EN/IEC 60947-1 and -2, JIS C8201-2-2, and GB/T 14048.2. It carries a CE marking for the European market. RoHS and REACH compliance documentation is typically available from Schneider Electric upon request — the product is designed for global distribution and meets the applicable environmental directives."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZC250N44100","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZC250N44100 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}