{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZC250N44125","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZC250N44125","canonicalUrl":"https://aoctrl.com/schneider/EZC250N44125","factsUrl":"https://aoctrl.com/api/mcp/products/EZC250N44125","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZC250N series, EZC250N44125, 4-pole circuit breaker, 125 A rated current, 20 kA Icu at 440 V AC, thermal-magnetic TM-D trip unit, fixed mount, IP20.","salesMarkdown":"The Schneider Electric EZC250N44125 is a 4-pole EasyPact EZC250N circuit breaker with a thermal-magnetic TM-D trip unit, rated 125 A at 40 °C and delivering a 20 kA Icu breaking capacity at 440 V AC. It's built to IEC 60947-2 for distribution duty — the standard that governs molded-case breakers in commercial and industrial panels. If your panel runs hotter — say 50 °C — the trip unit rating drops to 125 A at 50 °C, meaning the breaker still holds its full rating at that elevated ambient, no derate penalty. That's unusual for a thermal-magnetic; most need a size bump at 50 °C. Breaking capacity varies by voltage: 50 kA at 220–240 V AC, 25 kA at 380–415 V AC, 20 kA at 440 V AC, and 8 kA at 550 V AC. On the DC side, it's 20 kA at 125 V DC (1-pole) and 20 kA at 250 V DC (2-pole). That 690 V Ui tells you the internal creepage and clearance are designed for 690 V systems, even though the breaker's operational rating is 550 V. This is a fixed-mount breaker on a backplate, not a DIN-rail snap-on. Connection pitch is 35 mm — standard for busbar or cable lug termination in a distribution board.","metaTitle":"Schneider Electric EZC250N44125 EasyPact EZC250N, 125 A, 20","metaDescription":"Schneider Electric EZC250N44125 EasyPact EZC250N circuit breaker, 125 A rated current, 20 kA Icu at 440 V AC. Thermal-magnetic TM-D trip unit, 4 poles. Active production. Quoted to","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"60 mm","Width":"140 mm","Height":"165 mm","Voltage":"550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2","IP Rating":"IP20","Application":"Distribution","Control Type":"Toggle","Network Type":"DC AC","Product Status":"Active","Terminal Pitch":"35 mm","Trip Unit Type":"Thermal-magnetic","Pollution Degree":"3 conforming to IEC 60947","Temp Storage Max":"85 °C","Temp Storage Min":"-35 °C","Breaking Capacity":"20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 125 V DC 1P conforming to IEC 60947-2 20 kA Icu at 250 V DC 2P conforming to IEC 60947-2 8 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2","Insulation Voltage Ui":"690 V AC 50/60 Hz conforming to IEC 60947-2","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-35...85 °C","Connection Surface Top":"Front","Mechanical Life Cycles":"10000 cycles","Connection Surface Bottom":"Front","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1ff35313915339814e28750a5bf65507.pdf","sourceUrl":"https://www.se.com/ae/en/product/EZC250N44125/circuit-breaker-easypact-ezc250n-tmd-125-a-4-poles-4d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/EZC250N44125/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZC250N44125","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZC250N44125 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}