{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZC250N44200","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZC250N44200","canonicalUrl":"https://aoctrl.com/schneider/EZC250N44200","factsUrl":"https://aoctrl.com/api/mcp/products/EZC250N44200","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZC250N series, EZC250N44200, 4-pole thermal-magnetic circuit breaker, 200 A rated current, 20 kA breaking capacity at 440 V AC, IEC 60947-2.","salesMarkdown":"The Schneider Electric EZC250N44200 is a 4-pole EasyPact EZC250N thermal-magnetic circuit breaker rated 200 A at 40 °C (200 A at 50 °C on the trip unit). It carries a 20 kA Icu at 440 V AC — the N breaking capacity code — and is certified to IEC 60947-2. The TM-D trip unit provides short-circuit and overload protection; there is no integral earth-leakage module. It ships as a fixed-mount, front-connect unit with a toggle handle and positive contact indication. The kit is complete: no missing brackets or separate trip units to order. The 20 kA Icu at 440 V AC is the headline fault-interruption figure for a 200 A frame in a distribution panel. At 380–415 V AC it rises to 25 kA, and at 220–240 V AC it reaches 50 kA — useful for high-fault locations near a transformer. On DC, it manages 20 kA at 125 V (1-pole) or 250 V (2-pole). The 8 kA Icu at 550 V AC is the ceiling for the rated operational voltage. For a Category A breaker (no intentional short-time delay), selectivity with downstream devices depends on the instantaneous trip threshold of the TM-D unit. Fixed backplate mount, 35 mm connection pitch, front terminals top and bottom. Dimensions: 165 mm high, 140 mm wide, 60 mm deep. IP20 finger-safe enclosure; IK07 impact resistance. No neutral protection fitted — the 4t protected poles cover all four phases, with the neutral unprotected.","metaTitle":"Schneider Electric EZC250N44200 EasyPact EZC250N 200A 4P Cir","metaDescription":"Schneider Electric EasyPact EZC250N EZC250N44200 200A 4P thermal-magnetic circuit breaker. 20 kA Icu at 440 V AC. IEC 60947-2. Current lifecycle. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"60 mm","Width":"140 mm","Height":"165 mm","Standards":"EN/IEC 60947-2 JIS C8201-2-2 GB/T 14048.2 EN/IEC 60947-1","Control type":"Toggle","Network type":"AC DC","Mounting mode":"Fixed","Trip unit name":"TM-D","Protection type":"Short-circuit protection Overload protection","lifecycle_stage":"current","Connection pitch":"35 mm","Local signalling":"Positive contact indication","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60947","Range of product":"EasyPact","Trip unit rating":"200 A at 50 °C","Breaking capacity":"20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 125 V DC 1P conforming to IEC 60947-2 20 kA Icu at 250 V DC 2P conforming to IEC 60947-2 8 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"Easypact EZC250N","Network frequency":"50/60 Hz","Poles description":"4P","Upside connection":"Front","Device application":"Distribution","[In] rated current":"200 A at 40 °C","Downside connection":"Front","Circuit breaker name":"Easypact EZC250N","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Mechanical durability":"10000 cycles","Breaking capacity code":"N","IK degree of protection":"IK07 conforming to EN 50102","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Neutral protection setting":"Without protection","Protected poles description":"4t","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2","Ambient air temperature for storage":"-35...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 125 V DC conforming to IEC 60947-2 10 kA at 250 V DC conforming to IEC 60947-2 4 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e1a098e7cd93872b2a63608d7156adae.pdf","sourceUrl":"https://www.se.com/sg/en/product/EZC250N44200/circuit-breaker-easypact-ezc250n-tmd-200-a-4-poles-4d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/EZC250N44200/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy EZC250N44200?","answer":"It is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What are the key ratings of EZC250N44200?","answer":"Rated current 200 A at 40 °C, 20 kA Icu at 440 V AC, 4 poles, thermal-magnetic TM-D trip unit, IEC 60947-2."},{"question":"What compliance documentation does this brand provide for EZC250N44200?","answer":"The breaker is certified to IEC 60947-2, JIS C8201-2-2, GB/T 14048.2, and IEC 60947-1. It is suitable for isolation per IEC 60947-2."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZC250N44200","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZC250N44200 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}