{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZC250N44250","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZC250N44250","canonicalUrl":"https://aoctrl.com/schneider/EZC250N44250","factsUrl":"https://aoctrl.com/api/mcp/products/EZC250N44250","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZC250N, EZC250N44250, 4-pole circuit breaker, 250 A rated current, TM-D thermal-magnetic trip unit, 20 kA Icu at 440 V AC, front connections, backplate mount.","salesMarkdown":"The EZC250N44250 is a Schneider Electric EasyPact EZC250N 4-pole circuit breaker with a TM-D thermal-magnetic trip unit rated 250 A at 40 °C. It ships as a fixed-mount, front-connection unit with toggle control and positive contact indication — no earth-leakage module, no neutral protection. The kit is complete: backplate mounting support, 35 mm connection pitch, IP20 finger-safe enclosure. At 380–415 V AC the rating climbs to 25 kA Icu; at 220–240 V AC it hits 50 kA Icu. For DC circuits, it manages 20 kA Icu at 125 V DC (1 pole) and 20 kA Icu at 250 V DC (2 poles). The N breaking capacity code means it is sized for standard distribution panels where fault levels stay under 25 kA at 400 V — not for high-fault industrial mains. ## Integration into a distribution panel Mounts to a backplate via the fixed-mount support. The 60 mm depth fits standard 200 mm deep enclosures; the 140 mm width and 165 mm height occupy a 4-pole footprint.","metaTitle":"Schneider Electric EZC250N44250 EasyPact EZC250N, 250 A, 4P,","metaDescription":"Schneider Electric EZC250N44250 EasyPact EZC250N circuit breaker, 250 A, 4 poles, TM-D trip unit, 20 kA Icu at 440 V AC. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"60 mm","Width":"140 mm","Height":"165 mm","Standards":"EN/IEC 60947-1 GB/T 14048.2 JIS C8201-2-2 EN/IEC 60947-2","Control type":"Toggle","Network type":"DC AC","Mounting mode":"Fixed","Trip unit name":"TM-D","Protection type":"Overload protection Short-circuit protection","lifecycle_stage":"current","Connection pitch":"35 mm","Local signalling":"Positive contact indication","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60947","Range of product":"EasyPact","Trip unit rating":"250 A at 50 °C","Breaking capacity":"20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 125 V DC 1P conforming to IEC 60947-2 20 kA Icu at 250 V DC 2P conforming to IEC 60947-2 8 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"Easypact EZC250N","Network frequency":"50/60 Hz","Poles description":"4P","Upside connection":"Front","Device application":"Distribution","[In] rated current":"250 A at 40 °C","Downside connection":"Front","Circuit breaker name":"Easypact EZC250N","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Mechanical durability":"10000 cycles","Breaking capacity code":"N","IK degree of protection":"IK07 conforming to EN 50102","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Neutral protection setting":"Without protection","Protected poles description":"4t","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2","Ambient air temperature for storage":"-35...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 125 V DC conforming to IEC 60947-2 10 kA at 250 V DC conforming to IEC 60947-2 4 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9054ebcca0f3aa8f06d81d823cb98f06.pdf","sourceUrl":"https://www.se.com/sg/en/product/EZC250N44250/circuit-breaker-easypact-ezc250n-tmd-250-a-4-poles-4d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/EZC250N44250/alternatives.json"},"ai":{"faq":[{"question":"Who supplies EZC250N44250 and how is it quoted for volume purchases?","answer":"The EZC250N44250 is sourced and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time through our independent distribution network."},{"question":"What is the closest pin-compatible alternative to EZC250N44250 in this component family?","answer":"Within the EasyPact EZC250N family, the closest alternative would be a unit with the same frame and trip rating but a different breaking capacity code (e.g., H or S). The EZC250N44250 uses the N breaking capacity code; verify the required Icu at your system voltage before selecting a sibling."},{"question":"What compliance documentation does this brand provide for EZC250N44250 (RoHS, REACH, UL, IEC)?","answer":"The EZC250N44250 is certified to EN/IEC 60947-1, EN/IEC 60947-2, GB/T 14048.2, and JIS C8201-2-2. It carries IK07 impact protection and IP20 finger-safe enclosure. Suitability for isolation is confirmed per IEC 60947-2."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZC250N44250","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZC250N44250 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}