{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZC400H44400N","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZC400H44400N","canonicalUrl":"https://aoctrl.com/schneider/EZC400H44400N","factsUrl":"https://aoctrl.com/api/mcp/products/EZC400H44400N","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZC400H, MCCB, 400A, 4P, TM-D trip unit, 50kA Icu at 380-440V AC, fixed mount, front connections.","salesMarkdown":"## 400 A thermal-magnetic MCCB, 50 kA breaking capacity It carries 50 kA Icu at 380–440 V AC 50/60 Hz per IEC 60947-2, and 70 kA at 220–240 V AC. The TM-D trip unit combines thermal overload and magnetic short-circuit protection. Magnetic tripping is fixed at 4000 A. Rated for category A (no intentional time delay for selectivity with downstream breakers on short-circuit), 4000 electrical cycles at 415 V AC, and 10000 mechanical cycles. ## Physical integration and environment Dimensions are 255 mm high × 140 mm wide × 140 mm deep. The 45 mm pole pitch matches standard busbar systems. Fixed mounting on a backplate, with front-facing terminals for both line and load — no rear-connect option. IP20 finger-safe terminals, IK07 impact resistance.","metaTitle":"Schneider Electric EZC400H44400N EasyPact EZC400H, 400A, 50k","metaDescription":"Schneider Electric EZC400H44400N EasyPact EZC400H circuit breaker. 400A rated current, 50kA Icu at 380-440V AC, 4 poles, TM-D trip unit. Current lifecycle stage. Quoted to order ag","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Color":"Black","Depth":"140 mm","Width":"140 mm","Height":"255 mm","Voltage":"440 V AC 50/60 Hz conforming to IEC 60947-2","IP Rating":"IP20","Application":"Distribution","Control Type":"Toggle","Product Status":"Active","Terminal Pitch":"45 mm","Trip Unit Type":"Thermal-magnetic","Pollution Degree":"3 conforming to IEC 60947","Temp Storage Max":"85 °C","Temp Storage Min":"-35 °C","Breaking Capacity":"50 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2","Insulation Voltage Ui":"690 V AC 50/60 Hz conforming to IEC 60947-2","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-35...85 °C","Connection Surface Top":"Front","Electrical Life Cycles":"Category A: 4000 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2","Mechanical Life Cycles":"10000 cycles","Connection Surface Bottom":"Front","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2c54ad853289648079f715417bcfb17b.pdf","sourceUrl":"https://www.se.com/ae/en/product/EZC400H44400N/circuit-breaker-easypact-ezc400h-tmd-400-a-4-poles-4d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/EZC400H44400N/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZC400H44400N","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZC400H44400N when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}