{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZC630H3500N","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZC630H3500N","canonicalUrl":"https://aoctrl.com/schneider/EZC630H3500N","factsUrl":"https://aoctrl.com/api/mcp/products/EZC630H3500N","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZC630H, EZC630H3500N, 3P, 630 A at 40 °C, 50 kA Icu at 380 V AC, thermal-magnetic TM-D trip unit, fixed mount, IP20.","salesMarkdown":"The Schneider Electric EZC630H3500N is a 3-pole EasyPact EZC630H moulded-case circuit breaker rated 630 A at 40 °C, with a thermal-magnetic TM-D trip unit. It provides short-circuit and overload protection for distribution applications, with a breaking capacity of 50 kA Icu at 380 V AC and 50/60 Hz per IEC 60947-2. The 630 A frame means it handles high-current feeds — main switchboard incomers, large motor control centre busbars, or transformer secondary protection — where the 50 kA fault level is common in industrial plant. The magnetic trip is fixed at 6000 A, giving an instantaneous pickup of roughly 10× In — typical for distribution-grade MCCBs, meaning it clears high-impedance faults quickly but will ride through motor inrush on downstream starters. Breaking capacity is 50 kA Icu at 380 V, 440 V, and 400/415 V — the same 50 kA holds across the common industrial voltage band. At 220/230 V it rises to 70 kA. For a distribution board with a transformer secondary fault current of 45 kA, this breaker holds the line; above 50 kA you need the H- or L-frame variant. The breaker is Category A (no intentional short-time delay), so it trips instantaneously on fault — selectivity with downstream devices relies on current discrimination, not time grading. Mechanical durability is 10 000 cycles, electrical durability 3000 cycles at 415 V — adequate for a main breaker that operates a few times a year, but not for a switching duty like a welding machine or frequent motor start. The IP20 finger-safe enclosure and IK07 impact resistance protect against accidental contact and light mechanical shock inside the panel. Fixed-mount via backplate — no DIN-rail adapter. The 140 mm width × 255 mm height × 110 mm depth footprint fits standard panel cutouts for 630 A frame MCCBs. Front connection both top and bottom; connection pitch is 45 mm. Toggle control with positive contact indication; the suitability-for-isolation mark (per IEC 60947-2) means the breaker can be used as a disconnecting means — no need for a separate isolator upstream.","metaTitle":"Schneider Electric EZC630H3500N EasyPact EZC630H, 630A, 50kA","metaDescription":"Schneider Electric EasyPact EZC630H3500N circuit breaker, 630 A at 40 °C, 50 kA Icu at 380-440 V, thermal-magnetic TM-D trip, IEC 60947-2, current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"110 mm","Width":"140 mm","title":"EZC630H3500N","Colour":"Black","Height":"255 mm","Standards":"GB/T 14048.2 EN/IEC 60947-2 JIS C8201-2-2 EN/IEC 60947-1","description":"circuit breaker, Easypact EZC630H, TMD, 500A, 3 poles 3d","Control type":"Toggle","Network type":"AC","Mounting mode":"Fixed","Trip unit name":"TM-D","Protection type":"Short-circuit protection Overload protection","lifecycle_stage":"current","Connection pitch":"45 mm","Local signalling":"Positive contact indication","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60947","Quantity per set":"1 piece","Range of product":"EasyPact","Trip unit rating":"500 A at 50 °C","Breaking capacity":"50 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"Easypact EZC630H","Network frequency":"50/60 Hz","Poles description":"3P","Upside connection":"Front","Device application":"Distribution","[In] rated current":"630 A at 40 °C","Downside connection":"Front","Circuit breaker name":"Easypact EZC630H","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Electrical durability":"Category A: 3000 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2","Mechanical durability":"10000 cycles","Breaking capacity code":"H","IK degree of protection":"IK07 conforming to EN 50102","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"Without","Magnetic tripping current":"6000 A","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","Neutral protection setting":"Without protection","Protected poles description":"3t","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"440 V AC 50/60 Hz conforming to IEC 60947-2","Long time delay adjustment type":"Fixed","Ambient air temperature for storage":"-35...85 °C","Long time pick-up adjustment type Ir":"Fixed","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"25 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 70 kA at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d8cd4d2f9bdfe5410c13a69c91f16c2f.pdf","sourceUrl":"https://www.se.com/vn/en/product/EZC630H3500N/circuit-breaker-easypact-ezc630h-tmd-500a-3-poles-3d/"},"ai":{"faq":[{"question":"What is the breaking capacity of EZC630H3500N?","answer":"50 kA Icu at 380 V, 440 V, and 400/415 V AC; 70 kA Icu at 220/230 V AC, all per IEC 60947-2."},{"question":"Where can I buy EZC630H3500N?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What standards does EZC630H3500N comply with?","answer":"It complies with GB/T 14048.2, EN/IEC 60947-2, and JIS C8201-2-2."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZC630H3500N","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZC630H3500N when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}