{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZC630H3600N","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZC630H3600N","canonicalUrl":"https://aoctrl.com/schneider/EZC630H3600N","factsUrl":"https://aoctrl.com/api/mcp/products/EZC630H3600N","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZC630H, circuit breaker, 630 A at 40 °C, 3P, TM-D thermal-magnetic trip unit, 50 kA Icu at 380 V AC, fixed mount, IP20.","salesMarkdown":"The EZC630H3600N is a 3-pole EasyPact EZC630H circuit breaker rated 630 A at 40 °C (In) with a TM-D thermal-magnetic trip unit. Breaking capacity is 50 kA Icu at 380 V AC, 50 kA at 400/415 V AC, and 50 kA at 440 V AC per IEC 60947-2. At 220/230 V AC it rises to 70 kA Icu. The 'H' breaking capacity code indicates the high-interrupting version — suitable for installations with high available fault current, such as industrial switchboards close to a transformer. This breaker is category A (no intentional short-time delay), with electrical endurance of 3000 cycles at 415 V AC and mechanical endurance of 10000 cycles. The IP20 finger-safe enclosure and IK07 impact resistance allow installation in accessible indoor panels where accidental contact or light mechanical impact is a concern. The breaker complies with EN/IEC 60947-2, GB/T 14048.2, and JIS C8201-2-2 standards. No earth-leakage protection module is integrated (without), so any ground-fault protection must be added externally if required. Fixed-mount design for backplate installation — no DIN-rail adapter. Dimensions: 255 mm height, 140 mm width, 110 mm depth. The 45 mm connection pitch between poles matches standard busbar spacing for 3-pole distribution blocks. The toggle control provides positive contact indication, so the operator can visually confirm the contact position.","metaTitle":"Schneider Electric EZC630H3600N EasyPact EZC630H Circuit Bre","metaDescription":"Schneider Electric EZC630H3600N EasyPact EZC630H circuit breaker, 630 A rated at 40 °C, 3-pole, TM-D thermal-magnetic trip unit, 50 kA Icu at 380 V AC. Sourced to order against RFQ","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"110 mm","Width":"140 mm","title":"EZC630H3600N","Colour":"Black","Height":"255 mm","Standards":"EN/IEC 60947-2 GB/T 14048.2 JIS C8201-2-2 EN/IEC 60947-1","description":"circuit breaker Easypact EZC630H - TMD - 600 A - 3 poles 3d","Control type":"Toggle","Network type":"AC","Mounting mode":"Fixed","Trip unit name":"TM-D","Protection type":"Short-circuit protection Overload protection","lifecycle_stage":"current","Connection pitch":"45 mm","Local signalling":"Positive contact indication","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60947","Quantity per set":"1 piece","Range of product":"EasyPact","Trip unit rating":"600 A at 50 °C","Breaking capacity":"50 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"Easypact EZC630H","Network frequency":"50/60 Hz","Poles description":"3P","Upside connection":"Front","Device application":"Distribution","[In] rated current":"630 A at 40 °C","Downside connection":"Front","Circuit breaker name":"Easypact EZC630H","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Electrical durability":"Category A: 3000 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2","Mechanical durability":"10000 cycles","Breaking capacity code":"H","IK degree of protection":"IK07 conforming to EN 50102","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"Without","Magnetic tripping current":"4000 A","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","Neutral protection setting":"Without protection","Protected poles description":"3t","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"440 V AC 50/60 Hz conforming to IEC 60947-2","Long time delay adjustment type":"Fixed","Ambient air temperature for storage":"-35...85 °C","Long time pick-up adjustment type Ir":"Fixed","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"25 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 70 kA at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/fc593e702a49ee5d9836a96bd62e18bb.pdf","sourceUrl":"https://www.se.com/ae/en/product/EZC630H3600N/circuit-breaker-easypact-ezc630h-tmd-600-a-3-poles-3d/"},"ai":{"faq":[{"question":"Who supplies EZC630H3600N and how is it quoted for volume purchases?","answer":"The EZC630H3600N is sourced through independent industrial-automation distribution channels. It is quoted to order against an RFQ; availability and current pricing are confirmed at quote time."},{"question":"What is EZC630H3600N's breaking capacity at 400 V AC?","answer":"The breaking capacity is 50 kA Icu at 400/415 V AC per IEC 60947-2. At 380 V AC it is also 50 kA, and at 440 V AC it remains 50 kA. At 220/230 V AC the rating rises to 70 kA Icu."},{"question":"What compliance documentation does this breaker carry?","answer":"The EZC630H3600N complies with EN/IEC 60947-2, GB/T 14048.2, and JIS C8201-2-2. It is rated for pollution degree 3 per IEC 60947 and carries IP20 finger-safe protection and IK07 impact resistance."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZC630H3600N","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZC630H3600N when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}