{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZC630H44600N","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZC630H44600N","canonicalUrl":"https://aoctrl.com/schneider/EZC630H44600N","factsUrl":"https://aoctrl.com/api/mcp/products/EZC630H44600N","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZC630H, circuit breaker, EZC630H44600N, 630 A at 40 °C, 4 poles, TM-D thermal-magnetic trip unit, 50 kA Icu at 380-440 V AC, fixed mounting, front connection.","salesMarkdown":"The EZC630H44600N is a 4-pole EasyPact EZC630H moulded-case circuit breaker rated 630 A at 40 °C ambient — the current you spec for the main feeder or large motor branch, not a subfeed. The TM-D thermal-magnetic trip unit gives fixed overload and short-circuit protection curves; no interchangeable rating plugs or electronic adjustments here, so the 630 A frame is the trip rating, not just a frame size you can down-rate. That simplifies BOM but means you commit to the full 630 A or drop to a smaller frame. Breaking capacity is 50 kA Icu at 380/400/415/440 V AC (50/60 Hz) per IEC 60947-2, and 70 kA Icu at 220/230 V AC. For a 630 A distribution breaker on a 400 V industrial panel, 50 kA Icu gives solid headroom over typical utility fault levels (usually 25–35 kA at the service entrance). The H breaking capacity code in EZC630H signals this is the high-interrupting variant of the EZC630 family. For frequent switching duty, add a contactor downstream. ## Deployment context Fixed mounting on a backplate with front-front connections — line and load cables both terminate on the front face. The 185 mm width, 255 mm height, and 140 mm depth require clearance for 630 A conductors. IP20 finger-safe protection on the front and IK07 impact resistance cover normal panel installation. This is not a washdown-rated enclosure — keep it inside a cabinet rated IP54 or better if the environment is wet or dusty. Standards compliance covers GB/T 14048.2, JIS C8201-2-2, EN/IEC 60947-1, and EN/IEC 60947-2. No UL or CSA listing is stated in the evidence. Toggle control with positive contact indication gives a visible break confirmation — the handle position shows the contact state even if the mechanism fails internally. That is a useful diagnostic cue for field service techs isolating a faulted feeder: you see the handle in the OFF or tripped position and know the contacts have opened.","metaTitle":"Schneider Electric EZC630H44600N EasyPact EZC630H, 630 A, 4P","metaDescription":"Schneider Electric EZC630H44600N EasyPact EZC630H circuit breaker. 630 A rated at 40 °C, 4 poles, thermal-magnetic TM-D trip unit, 50 kA Icu at 380-440 V AC. Current lifecycle stag","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Color":"Black","Depth":"140 mm","Width":"185 mm","Height":"255 mm","Voltage":"440 V AC 50/60 Hz conforming to IEC 60947-2","IP Rating":"IP20","Application":"Distribution","Control Type":"Toggle","Product Status":"Active","Terminal Pitch":"45 mm","Trip Unit Type":"Thermal-magnetic","Pollution Degree":"3 conforming to IEC 60947","Temp Storage Max":"85 °C","Temp Storage Min":"-35 °C","Insulation Voltage Ui":"690 V AC 50/60 Hz conforming to IEC 60947-2","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-35...85 °C","Connection Surface Top":"Front","Electrical Life Cycles":"Category A: 3000 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2","Mechanical Life Cycles":"10000 cycles","Connection Surface Bottom":"Front","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9d20c189cf9f05ae785dd6d1b39595d6.pdf","sourceUrl":"https://www.se.com/vn/en/product/EZC630H44600N/circuit-breaker-easypact-ezc630h-tmd-600-a-4-poles-4d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/EZC630H44600N/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZC630H44600N","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZC630H44600N when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}