{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZC630N4500N","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZC630N4500N","canonicalUrl":"https://aoctrl.com/schneider/EZC630N4500N","factsUrl":"https://aoctrl.com/api/mcp/products/EZC630N4500N","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZC630N, EZC630N4500N, 4-pole molded case circuit breaker, 630 A rated current, 36 kA breaking capacity at 440 V AC, thermal-magnetic TM-D trip unit, fixed mount.","salesMarkdown":"It's a 4-pole unit with a 36 kA Icu breaking capacity at 440 V AC 50/60 Hz, compliant with IEC 60947-2. The fixed-mount design with front connections and a 45 mm pole pitch makes it a straightforward panel fit for distribution applications. At 380 V AC and 400/415 V AC it holds the same 36 kA rating, and at 220/230 V AC it steps up to 40 kA Icu. For a 630 A frame, that gives you decent selectivity headroom downstream of a higher-rated upstream device, especially in 400 V distribution panels. The TM-D thermal-magnetic trip unit is rated 500 A at 50 °C, with a fixed magnetic trip threshold of 5000 A. That's a standard fixed-trip thermal-magnetic — no interchangeable rating plugs or electronic adjustments. ## Physical integration Fixed mounting on a backplate, front connections both top and bottom. The 185 mm width, 255 mm height, and 140 mm depth give you the envelope for panel layout. IP20 finger-safe protection on the front, IK07 impact resistance. The toggle control and positive contact indication give a clear visual on breaker status. No earth-leakage protection module on this variant.","metaTitle":"Schneider Electric EZC630N4500N EasyPact EZC630N, 630 A, 36","metaDescription":"Schneider Electric EZC630N4500N EasyPact EZC630N molded case circuit breaker, 630 A rated current, 36 kA breaking capacity at 440 V AC, 4 poles, thermal-magnetic TM-D trip unit. Cu","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"140 mm","Width":"185 mm","title":"EZC630N4500N","Colour":"Black","Height":"255 mm","Standards":"EN/IEC 60947-1 JIS C8201-2-2 EN/IEC 60947-2 GB/T 14048.2","description":"circuit breaker, Easypact EZC630N, TMD, 500A, 4 poles 3d","Control type":"Toggle","Network type":"AC","Mounting mode":"Fixed","Trip unit name":"TM-D","Protection type":"Short-circuit protection Overload protection","lifecycle_stage":"current","Connection pitch":"45 mm","Local signalling":"Positive contact indication","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60947","Quantity per set":"1 piece","Range of product":"EasyPact","Trip unit rating":"500 A at 50 °C","Breaking capacity":"36 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"Easypact EZC630N","Network frequency":"50/60 Hz","Poles description":"4P","Upside connection":"Front","Device application":"Distribution","[In] rated current":"630 A at 40 °C","Downside connection":"Front","Circuit breaker name":"Easypact EZC630N","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Electrical durability":"Category A: 3000 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2","Mechanical durability":"10000 cycles","Breaking capacity code":"N","IK degree of protection":"IK07 conforming to EN 50102","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"Without","Magnetic tripping current":"5000 A","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","Neutral protection setting":"Without protection","Protected poles description":"3t","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"440 V AC 50/60 Hz conforming to IEC 60947-2","Long time delay adjustment type":"Fixed","Ambient air temperature for storage":"-35...85 °C","Long time pick-up adjustment type Ir":"Fixed","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"18 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 40 kA at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9d6ddaf6a3e116592b60fb2bd1f14845.pdf","sourceUrl":"https://www.se.com/vn/en/product/EZC630N4500N/circuit-breaker-easypact-ezc630n-tmd-500a-4-poles-3d/"},"ai":{"faq":[{"question":"Where can I buy EZC630N4500N and how do I get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What is the breaking capacity of the EZC630N4500N at 440 V?","answer":"36 kA Icu at 440 V AC 50/60 Hz per IEC 60947-2. At 220/230 V AC it's rated 40 kA Icu."},{"question":"What compliance standards does the EZC630N4500N meet?","answer":"It complies with EN/IEC 60947-1, EN/IEC 60947-2, JIS C8201-2-2, and GB/T 14048.2. It is suitable for isolation per IEC 60947-2."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZC630N4500N","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZC630N4500N when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}