{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZCV250H3175","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZCV250H3175","canonicalUrl":"https://aoctrl.com/schneider/EZCV250H3175","factsUrl":"https://aoctrl.com/api/mcp/products/EZCV250H3175","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZCV250H series, molded case circuit breaker, 3-pole, 175 A thermal-magnetic TM-D trip unit, 100 kA Icu at 240 V AC, IP20 finger-safe enclosure.","salesMarkdown":"The Schneider Electric EZCV250H3175 is a 3-pole molded case circuit breaker from the EasyPact EZCV250H series, fitted with a TM-D thermal-magnetic trip unit rated at 175 A at 40 °C. This is the distribution-grade variant with earth-leakage protection integrated, intended for fixed-mount backplate installation in panelboards and switchboards. Breaking capacity is the headline selector here: 100 kA Icu at 220–240 V AC, 36 kA at 380–415 V, and 25 kA at 440 V — all per IEC 60947-2. That H breaking-capacity code means it handles high prospective fault currents at the lower distribution voltages common in commercial and light industrial mains, so it can be applied upstream without a current-limiting fuse for coordination. The 105 mm width and 165 mm height fit standard panel cutouts for the EZCV250H frame. IP20 finger-safe enclosure per IEC 60529 and IK07 impact resistance per EN 50102. ## Protection and Duty Earth-leakage protection is onboard, so this single device covers overcurrent and ground-fault in one footprint — a space-saving choice compared to a separate RCCB plus MCCB combination.","metaTitle":"Schneider Electric EZCV250H3175 EasyPact MCCB, 175 A, 100 kA","metaDescription":"Schneider Electric EZCV250H3175 EasyPact EZCV250H molded case circuit breaker, 175 A thermal-magnetic TM-D trip, 100 kA Icu at 240 V AC. Current production. Sourced to order agains","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"68 mm","Width":"105 mm","Height":"165 mm","Standards":"JIS C8201-2-2 EN/IEC 60947-2 EN/IEC 60947-1 GB/T 14048.2","Control type":"Toggle","Network type":"AC","Mounting mode":"Fixed","Trip unit name":"TM-D","Protection type":"Overload protection Short-circuit protection Earth-leakage protection","lifecycle_stage":"current","Connection pitch":"35 mm","Local signalling":"Positive contact indication","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60947","Range of product":"EasyPact","Trip unit rating":"175 A at 40 °C","Breaking capacity":"100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"Easypact EZCV250H","Network frequency":"50/60 Hz","Poles description":"3P","Upside connection":"Front","Device application":"Distribution","[In] rated current":"175 A at 40 °C","Downside connection":"Front","Circuit breaker name":"Easypact EZCV250H","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Mechanical durability":"10000 cycles","Breaking capacity code":"H","IK degree of protection":"IK07 conforming to EN 50102","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"With","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Neutral protection setting":"Without protection","Protected poles description":"3t","[Ui] rated insulation voltage":"440 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"440 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-35...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/687e09c6eb38927e648f30a6093df16f.pdf","sourceUrl":"https://www.se.com/ng/en/product/EZCV250H3175/circuit-breaker-easypact-ezcv250h-tmd-175-a-3-poles-3d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/EZCV250H3175/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative to EZCV250H3175 in the EasyPact family?","answer":"Within the same EZCV250H frame, the closest alternative is a variant with a different trip rating or without earth-leakage protection. The TM-D trip unit and H breaking-capacity code are consistent across the series; the deciding factor is the 175 A setting and the integrated earth-leakage function, which distinguishes this order code from the non-ELB versions."},{"question":"What compliance documentation does Schneider provide for EZCV250H3175?","answer":"The breaker is certified to IEC 60947-2, IEC 60947-1, JIS C8201-2-2, and GB/T 14048.2. It is suitable for isolation per IEC 60947-2 and carries IP20 and IK07 ratings. RoHS and REACH declarations are available from the manufacturer upon request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZCV250H3175","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZCV250H3175 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}