{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZCV250H3250","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZCV250H3250","canonicalUrl":"https://aoctrl.com/schneider/EZCV250H3250","factsUrl":"https://aoctrl.com/api/mcp/products/EZCV250H3250","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZCV250H series, EZCV250H3250, 3-pole MCCB, 250 A at 40 °C, thermal-magnetic trip unit TM-D, 100 kA Icu at 240 V AC, earth-leakage protection, IP20.","salesMarkdown":"## MCCB for distribution — 250 A thermal-magnetic with earth-leakage The Schneider Electric EZCV250H3250 is a 3-pole EasyPact EZCV250H moulded-case circuit breaker rated 250 A at 40 °C, built for distribution duty in fixed-mount backplate panels. The TM-D thermal-magnetic trip unit handles overload and short-circuit protection, and the integrated earth-leakage protection covers ground faults without a separate module — one less component to wire into the enclosure. Breaking capacity hits 100 kA Icu at 220–240 V AC, 36 kA at 380–415 V, and 25 kA at 440 V — all per IEC 60947-2. That 100 kA figure at common 240 V distribution voltage gives real selectivity headroom downstream; you can coordinate this with smaller branch breakers without worrying about cascading faults through the main. The H breaking-capacity code tells you it's the high-interrupt version in the EZCV250 family. Fixed-mount on a backplate, front-connected both line and load sides. Connection pitch is 35 mm, standard for busbar or cable lug termination. IP20 finger-safe on the front; IK07 impact rating means it handles a tool drop during panel assembly. Built to IEC 60947-2, JIS C8201-2-2, and GB/T 14048.2.","metaTitle":"Schneider Electric EZCV250H3250 EasyPact MCCB, 250 A, 100 kA","metaDescription":"Schneider Electric EZCV250H3250 EasyPact EZCV250H MCCB, 250 A rated at 40 °C, 100 kA Icu at 240 V AC, 3-pole thermal-magnetic with earth-leakage protection. Current lifecycle stage","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"68 mm","Width":"105 mm","Height":"165 mm","Standards":"EN/IEC 60947-2 JIS C8201-2-2 EN/IEC 60947-1 GB/T 14048.2","Control type":"Toggle","Network type":"AC","Mounting mode":"Fixed","Trip unit name":"TM-D","Protection type":"Earth-leakage protection Short-circuit protection Overload protection","lifecycle_stage":"current","Connection pitch":"35 mm","Local signalling":"Positive contact indication","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60947","Range of product":"EasyPact","Trip unit rating":"250 A at 40 °C","Breaking capacity":"100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"Easypact EZCV250H","Network frequency":"50/60 Hz","Poles description":"3P","Upside connection":"Front","Device application":"Distribution","[In] rated current":"250 A at 40 °C","Downside connection":"Front","Circuit breaker name":"Easypact EZCV250H","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Mechanical durability":"10000 cycles","Breaking capacity code":"H","IK degree of protection":"IK07 conforming to EN 50102","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"With","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Neutral protection setting":"Without protection","Protected poles description":"3t","[Ui] rated insulation voltage":"440 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"440 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-35...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/73ffddc6c71ebc15d52d4afb3ede194e.pdf","sourceUrl":"https://www.se.com/ph/en/product/EZCV250H3250/circuit-breaker-easypact-ezcv250h-tmd-250-a-3-poles-3d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/EZCV250H3250/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy EZCV250H3250?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time."},{"question":"What is the breaking capacity of EZCV250H3250 at 240 V?","answer":"100 kA Icu at 220–240 V AC per IEC 60947-2, with 36 kA at 380–415 V and 25 kA at 440 V."},{"question":"What compliance documentation does Schneider provide for EZCV250H3250?","answer":"The breaker is certified to IEC 60947-2, JIS C8201-2-2, and GB/T 14048.2. Standards documentation and the product certificate are available through the manufacturer's documentation portal."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZCV250H3250","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZCV250H3250 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}