{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZCV250H4200","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZCV250H4200","canonicalUrl":"https://aoctrl.com/schneider/EZCV250H4200","factsUrl":"https://aoctrl.com/api/mcp/products/EZCV250H4200","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZCV250H series, EZCV250H4200 MCCB, 200 A, 4P, 100 kA Icu at 240 V AC, thermal-magnetic TM-D trip with earth-leakage protection.","salesMarkdown":"## What this MCCB delivers in a panel The Schneider Electric EasyPact EZCV250H4200 is a 200 A molded-case circuit breaker (MCCB) with four poles, built for distribution duty in commercial and industrial switchboards. Its thermal-magnetic TM-D trip unit handles overload and short-circuit protection, and the integrated earth-leakage protection saves an external module on the DIN rail. The 100 kA Icu at 220...240 V AC (50/60 Hz) means it can interrupt a fault current up to that level without damage to itself — critical for high-fault installations near large transformers or parallel feeders. ## Trip curve and selectivity The TM-D trip unit is thermal-magnetic — the thermal element tracks overloads (inverse-time), the magnetic element trips instantaneously on short-circuit. This breaker is Category A (no intentional short-time delay), so it coordinates downstream with fuses or smaller MCCBs but not with another Category A breaker in series unless the upstream unit has a higher Icu. For a 200 A feeder feeding a 160 A subpanel, this gives headroom for inrush without nuisance tripping. Fixed backplate mount — no DIN-rail clip, so plan a mounting plate or enclosure backpan. That pitch matches standard busbar systems and lug kits. IP20 finger-safe protection on the front; IK07 impact resistance means it survives a tool drop in a panel.","metaTitle":"Schneider EasyPact EZCV250H4200 MCCB, 200 A, 4P, 100 kA Icu","metaDescription":"Schneider EasyPact EZCV250H4200 MCCB, 200 A rated at 40 °C, 4 poles, 100 kA Icu at 240 V AC. Thermal-magnetic TM-D trip, earth-leakage protection. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"68 mm","Width":"140 mm","title":"EZCV250H4200","Height":"165 mm","Standards":"JIS C8201-2-2 GB/T 14048.2 EN/IEC 60947-2 EN/IEC 60947-1","description":"circuit breaker Easypact EZCV250H - TMD - 200 A - 4 poles 3d","Control type":"Toggle","Network type":"AC","Mounting mode":"Fixed","Trip unit name":"TM-D","Protection type":"Overload protection Short-circuit protection Earth-leakage protection","lifecycle_stage":"current","Connection pitch":"35 mm","Local signalling":"Positive contact indication","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60947","Range of product":"EasyPact","Trip unit rating":"200 A at 40 °C","Breaking capacity":"100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"Easypact EZCV250H","Network frequency":"50/60 Hz","Poles description":"4P","Upside connection":"Front","Device application":"Distribution","[In] rated current":"200 A at 40 °C","Downside connection":"Front","Circuit breaker name":"Easypact EZCV250H","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Mechanical durability":"10000 cycles","Breaking capacity code":"H","IK degree of protection":"IK07 conforming to EN 50102","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"With","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Neutral protection setting":"Without protection","Protected poles description":"3t","[Ui] rated insulation voltage":"440 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"440 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-35...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e542160be9f83390b3102c15bf67f29c.pdf","sourceUrl":"https://www.se.com/ae/en/product/EZCV250H4200/circuit-breaker-easypact-ezcv250h-tmd-200-a-4-poles-3d/"},"ai":{"faq":[{"question":"What is the breaking capacity of the EZCV250H4200 at different voltages?","answer":"At 220...240 V AC it delivers 100 kA Icu; at 380...415 V AC it delivers 36 kA Icu; at 440 V AC it delivers 25 kA Icu, all per IEC 60947-2."},{"question":"Does the EZCV250H4200 include earth-leakage protection?","answer":"Yes, the breaker has integrated earth-leakage protection, so you don't need a separate add-on module for ground-fault detection."},{"question":"What compliance standards does the EZCV250H4200 meet?","answer":"It complies with JIS C8201-2-2, GB/T 14048.2, EN/IEC 60947-2, and EN/IEC 60947-1, covering Japanese, Chinese, and international industrial standards."},{"question":"Where can I buy the EZCV250H4200?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZCV250H4200","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZCV250H4200 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}