{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZCV250H44160","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZCV250H44160","canonicalUrl":"https://aoctrl.com/schneider/EZCV250H44160","factsUrl":"https://aoctrl.com/api/mcp/products/EZCV250H44160","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZCV250H, molded case circuit breaker, 4P, 160 A at 40 °C, TM-D thermal-magnetic trip unit, 100 kA Icu at 240 V AC, with earth-leakage protection.","salesMarkdown":"The 4P configuration with earth-leakage protection (integral, not add-on) suits TN or TT systems where you need both overcurrent and ground-fault protection in one package. ## Deployment context Mounts on a backplate (fixed mounting, not DIN rail) with front connections both top and bottom. Pollution degree 3 per IEC 60947 covers industrial atmospheres with conductive or dry non-conductive pollution, typical of most control rooms and switchgear enclosures. The toggle handle provides positive contact indication — you can see and feel the contact position, which simplifies lockout/tagout verification. Certified to GB/T 14048.2, EN/IEC 60947-2, and JIS C8201-2-2. The IEC 60947-2 listing covers the breaking capacity ratings and the isolation suitability mark — the breaker is certified for use as a disconnecting means (isolation function) per that standard. The IK07 impact rating (per EN 50102) means the enclosure withstands a 2 J impact, typical for industrial switchgear.","metaTitle":"Schneider Electric EZCV250H44160 EasyPact EZCV250H, 160 A, 1","metaDescription":"Schneider Electric EZCV250H44160 EasyPact EZCV250H circuit breaker, 160 A rated current, 100 kA Icu at 240 V AC, 4P, thermal-magnetic TM-D trip unit with earth-leakage protection.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"68 mm","Width":"140 mm","Height":"165 mm","Voltage":"440 V AC 50/60 Hz conforming to IEC 60947-2","IP Rating":"IP20","Application":"Distribution","Control Type":"Toggle","Product Status":"Active","Terminal Pitch":"35 mm","Trip Unit Type":"Thermal-magnetic","Pollution Degree":"3 conforming to IEC 60947","Temp Storage Max":"85 °C","Temp Storage Min":"-35 °C","Breaking Capacity":"100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2","Insulation Voltage Ui":"440 V AC 50/60 Hz conforming to IEC 60947-2","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-35...85 °C","Connection Surface Top":"Front","Mechanical Life Cycles":"10000 cycles","Connection Surface Bottom":"Front","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a484a0928345981e844e6709f1ea1c68.pdf","sourceUrl":"https://www.se.com/vn/en/product/EZCV250H44160/circuit-breaker-easypact-ezcv250h-tmd-160-a-4-poles-4d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/EZCV250H44160/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZCV250H44160","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZCV250H44160 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}