{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZCV250N3100","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZCV250N3100","canonicalUrl":"https://aoctrl.com/schneider/EZCV250N3100","factsUrl":"https://aoctrl.com/api/mcp/products/EZCV250N3100","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZCV250N series, EZCV250N3100, 3-pole MCCB, 100 A thermal-magnetic TM-D trip unit, 20 kA Icu at 440 V AC, with integrated earth-leakage protection.","salesMarkdown":"## What this MCCB brings to an existing panel It breaks 20 kA Icu at 440 V AC (85 kA at 240 V AC) per IEC 60947-2, and carries integrated earth-leakage protection — so it covers both overcurrent and ground-fault in one device, no separate RCCB needed downstream. At 380–415 V it delivers 25 kA Icu, and at 220–240 V it hits 85 kA Icu, so it coordinates cleanly with a downstream 10 kA MCB without the main breaker opening first. The Category A utilisation rating tells you it is not intended for motor starting duty under IEC 60947-2; this is a line-side or feeder breaker, not a motor-circuit protector. ## Current production — no lifecycle concern It is a standard catalogue item in the EasyPact range, compliant with IEC 60947-2, GB/T 14048.2, and JIS C8201-2-2. Fixed backplate mounting, front-front connections (both line and load side), with a 35 mm connection pitch. The toggle control and positive contact indication give a visual break confirmation — useful for lockout/tagout. IP20 finger-safe terminals and IK07 impact rating mean it handles the usual panel environment without a separate enclosure.","metaTitle":"Schneider Electric EZCV250N3100 EasyPact MCCB, 100 A, 20 kA","metaDescription":"Schneider Electric EZCV250N3100 EasyPact EZCV250N MCCB, 3-pole, 100 A thermal-magnetic TM-D trip, 20 kA Icu at 440 V AC. Current production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"68 mm","Width":"105 mm","Height":"165 mm","Standards":"GB/T 14048.2 JIS C8201-2-2 EN/IEC 60947-2 EN/IEC 60947-1","Control type":"Toggle","Network type":"AC","Mounting mode":"Fixed","Trip unit name":"TM-D","Protection type":"Earth-leakage protection Short-circuit protection Overload protection","lifecycle_stage":"current","Connection pitch":"35 mm","Local signalling":"Positive contact indication","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60947","Range of product":"EasyPact","Trip unit rating":"100 A at 40 °C","Breaking capacity":"20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"Easypact EZCV250N","Network frequency":"50/60 Hz","Poles description":"3P","Upside connection":"Front","Device application":"Distribution","[In] rated current":"100 A at 40 °C","Downside connection":"Front","Circuit breaker name":"Easypact EZCV250N","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Mechanical durability":"10000 cycles","Breaking capacity code":"N","IK degree of protection":"IK07 conforming to EN 50102","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"With","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Neutral protection setting":"Without protection","Protected poles description":"3t","[Ui] rated insulation voltage":"440 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"440 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-35...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/65c0dccc8bf32d7cb9bf06c8a13243af.pdf","sourceUrl":"https://www.se.com/id/en/product/EZCV250N3100/circuit-breaker-easypact-ezcv250n-tmd-100-a-3-poles-3d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/EZCV250N3100/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy EZCV250N3100?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the closest alternative to EZCV250N3100 in the EasyPact family?","answer":"Within the same EZCV250N frame, the key variant is the thermal-magnetic only version (without earth-leakage) — same 100 A TM-D trip, same 20 kA Icu, but omits the integrated Vigi module. If you need the earth-leakage function, stick with the 3100 suffix; if you don't, the non-Vigi variant saves panel space and cost."},{"question":"What compliance documentation does Schneider provide for EZCV250N3100?","answer":"The breaker is certified to IEC 60947-2, GB/T 14048.2, and JIS C8201-2-2. It carries IP20 and IK07 ratings. Standard Schneider documentation includes the IEC declaration of conformity and the product datasheet; RoHS and REACH compliance statements are available on request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZCV250N3100","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZCV250N3100 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}